Tagging of the bowel content with an oral contrast facilitates CT Colonography with limited bowel preparation. Electronic colon cleansing (ECC) reconstructs the colon lumen, devoid of feces from a CT scan acquired with fecal fluid tagging. A popular method to estimate the stool composition in an image (with the purpose of removing it) is the well-established Expectation Maximization (EM) method. The tagged fluid residue appears as a contrast enhanced region with a largely horizontal interface with air above it. One of the issues is the partial volume (PV) effect that creates voxels with attenuations similar to that of the colon wall at the boundary of air and tagged fluid. We present here, a novel orientation prior formulated as a Markov Random Field that is included as part of the EM tissue segmentation framework to mitigate this PV effect at the air and tagged fluid layer. We show quantitative results on a simple synthetic dataset and qualitative results on patient data that highlight improvements due to the inclusion of the orientation prior.
引用
收藏
页码:2018 / 2021
页数:4
相关论文
共 50 条
  • [21] Informatics in Radiology Electronic Cleansing for Noncathartic CT Colonography: A Structure-Analysis Scheme
    Cai, Wenli
    Yoshida, Hiroyuki
    Zalis, Michael E.
    Naeppi, Janne Johannes
    Harris, Gordon J.
    RADIOGRAPHICS, 2010, 30 (03) : 585 - 602
  • [22] Evolutionary optimization with Markov random field prior
    Wang, X
    Wang, H
    IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2004, 8 (06) : 567 - 579
  • [23] Mosaic Decomposition: An Electronic Cleansing Method for Inhomogeneously Tagged Regions in Noncathartic CT Colonography
    Cai, Wenli
    Lee, June-Goo
    Zalis, Michael E.
    Yoshida, Hiroyuki
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 559 - 574
  • [24] CT colonography: size reduction of submerged colorectal polyps due to electronic cleansing and CT-window settings
    Braeuer, Christian
    Lefere, Philippe
    Gryspeerdt, Stefaan
    Ringl, Helmut
    Al-Mukhtar, Ali
    Apfaltrer, Paul
    Berzaczy, Dominik
    Fueger, Barbara
    Furtner, Julia
    Mueller-Mang, Christina
    Pones, Matthias
    Scharitzer, Martina
    Woitek, Ramona
    Graser, Anno
    Weber, Michael
    Mang, Thomas
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4766 - 4774
  • [25] CT colonography: size reduction of submerged colorectal polyps due to electronic cleansing and CT-window settings
    Christian Bräuer
    Philippe Lefere
    Stefaan Gryspeerdt
    Helmut Ringl
    Ali Al-Mukhtar
    Paul Apfaltrer
    Dominik Berzaczy
    Barbara Füger
    Julia Furtner
    Christina Müller-Mang
    Matthias Pones
    Martina Scharitzer
    Ramona Woitek
    Anno Graser
    Michael Weber
    Thomas Mang
    European Radiology, 2018, 28 : 4766 - 4774
  • [26] Dual-energy electronic cleansing for non-cathartic CT Colonography: a phantom study
    Cai, Wenli
    Liu, Bob
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [27] Mosaic decomposition method for detection and removal of inhomogeneously tagged regions in electronic cleansing for CT colonography
    Cai, Wenli
    Zalis, Michael
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915
  • [28] Virtual Colon Tagging for Electronic Cleansing in Dual-energy Fecal-tagging CT Colonography
    Cai, Wenli
    Kim, Se Hyung
    Lee, June-Goo
    Yoshida, Hiroyuki
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3736 - 3739
  • [29] Deep multi-spectral ensemble learning for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Kim, Se Hyung
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [30] Low-dose dual-energy electronic cleansing for fecal-tagging CT colonography
    Cai, Wenli
    Zhang, Da
    Lee, June-Goo
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670