Tagging of the bowel content with an oral contrast facilitates CT Colonography with limited bowel preparation. Electronic colon cleansing (ECC) reconstructs the colon lumen, devoid of feces from a CT scan acquired with fecal fluid tagging. A popular method to estimate the stool composition in an image (with the purpose of removing it) is the well-established Expectation Maximization (EM) method. The tagged fluid residue appears as a contrast enhanced region with a largely horizontal interface with air above it. One of the issues is the partial volume (PV) effect that creates voxels with attenuations similar to that of the colon wall at the boundary of air and tagged fluid. We present here, a novel orientation prior formulated as a Markov Random Field that is included as part of the EM tissue segmentation framework to mitigate this PV effect at the air and tagged fluid layer. We show quantitative results on a simple synthetic dataset and qualitative results on patient data that highlight improvements due to the inclusion of the orientation prior.
引用
收藏
页码:2018 / 2021
页数:4
相关论文
共 50 条
  • [1] Electronic colon-cleansing for CT colonography: diagnostic performance
    Juchems, Markus S.
    Ernst, Andrea
    Johnson, Peter
    Virmani, Sunny
    Brambs, Hans-Juergen
    Aschoff, Andrik J.
    ABDOMINAL IMAGING, 2009, 34 (03): : 359 - 364
  • [2] Electronic cleansing in CT colonography using a generative adversarial network
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2019: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2019, 10954
  • [3] Electronic colon-cleansing for CT colonography: diagnostic performance
    Markus S. Juchems
    Andrea Ernst
    Peter Johnson
    Sunny Virmani
    Hans-Juergen Brambs
    Andrik J. Aschoff
    Abdominal Imaging, 2009, 34 : 359 - 364
  • [4] An Expert System for Electronic Cleansing of Contrast in CT Colonography Images
    Manjunath, K. N.
    Prabhu, Gopalakrishna K.
    Siddalingaswamy, P. C.
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING APPLICATIONS (ICSIPA), 2015, : 71 - 76
  • [5] Deep learning for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Tom
    Kim, Se Hyung
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [6] Thin Layer Tissue Classification for Electronic Cleansing of CT Colonography Data
    van Ravesteijn, V. F.
    Vos, F. M.
    Serlie, I. W. O.
    Truyen, R.
    van Vliet, L. J.
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 184 - +
  • [7] Electronic cleansing in CT colonography using transformer-based UNet
    Tachibana, Rie
    Nappi, Janne J.
    Okamoto, Masaki
    Yoshida, Hiroyuki
    IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, MEDICAL IMAGING 2024, 2024, 12931
  • [8] 3D generative AI for electronic cleansing in CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Okamoto, Masaki
    Yoshida, Hiroyuki
    IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, MEDICAL IMAGING 2024, 2024, 12931
  • [9] Electronic cleansing for CT colonography using spectral-driven iterative reconstruction
    Nasirudin, Radin A.
    Nappi, Janne J.
    Hironaka, Toru
    Tachibana, Rie
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [10] Bowel cleansing methods prior to CT colonography - A prospective, comparative, randomized blinded study
    Pedersen, BG
    Christiansen, TEM
    Mortensen, FV
    Christensen, H
    Laurberg, S
    ACTA RADIOLOGICA, 2002, 43 (03) : 306 - 311