This paper presents a new non-contact method for measuring frost height on heat exchanger fins. Previously used methods only allow one or two measurements per minute and are thus only practical for smooth frosted surfaces with height variations in only one direction. The new method uses a laser and two light sensors to collect transmitted and reflected laser light from a frosted surface. A three-dimensional representation may be obtained by scanning several vertical sections at different locations on each heat exchanger fin that is coated with frost. Preliminary data is presented showing the distribution of frost height on a fin using the transmitted and reflected sensor signals.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 50 条
  • [31] THE EFFECT OF PUPIL SIZE ON REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS USING A CONFOCAL LASER-SCANNING SYSTEM
    FECHTNER, RD
    ESSOCK, EA
    BENE, D
    SMITH, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1347 - 1347
  • [32] Water Wave Height measurements using Laser beam Reflections
    Teh, Ke You
    Chaudhari, Nikhila
    Ludu, Andrei
    Demirkiran, Ilteris
    IEEE SOUTHEASTCON 2014, 2014,
  • [33] BOREAL FOREST HEIGHT ESTIMATION WITH SAR INTERFEROMETRY AND LASER MEASUREMENTS
    Praks, Jaan
    Hallikainen, Martti
    Seppanen, Jaakko
    Hyyppa, Juha
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 3733 - +
  • [34] Continuous scanning laser vibrometry for measurements on rotating structures
    Halkon, B
    Rothberg, S
    MODERN PRACTICE IN STRESS AND VIBRATION ANALYSIS, 2003, 440-4 : 245 - 252
  • [35] Scanning laser polarimetry (SLP) measurements following LASIK
    GursesOzden, R
    Barbieri, C
    Pons, M
    Buxton, D
    Liebmann, JM
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S660 - S660
  • [36] Measurements Validating the Confocal Scanning Laser Holography Microscope
    Jacquemin, Peter B.
    Herring, Rodney A.
    MICROSCOPY AND MICROANALYSIS, 2011, 17 (04) : 618 - 623
  • [37] REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE MACULA WITH A SCANNING LASER OPHTHALMOSCOPE
    MENEZES, AV
    GIUNTA, M
    CHISHOLM, L
    HARVEY, PT
    TULI, R
    DEVENYI, RG
    OPHTHALMOLOGY, 1995, 102 (02) : 230 - 235
  • [38] SCANNING LASER MICROSCOPE MEASUREMENTS OF SEMICONDUCTOR AND DEVICE PROPERTIES
    DIXON, AE
    DAMASKINOS, S
    OLIVER, BA
    ADSETT, RT
    JOURNAL OF THE CANADIAN CERAMIC SOCIETY, 1984, 53 : 21 - 27
  • [39] Vitreous opacities affect scanning laser polarimetry measurements
    Pons, ME
    Rothman, RF
    Ozden, RG
    Liebmann, JM
    Ritch, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (04) : 511 - 513
  • [40] Extrafoveal visual acuity measurements with the scanning laser ophthalmoscope
    Yoshida, A
    Ishiko, S
    Van de Velde, FJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S430 - S430