Vitreous opacities affect scanning laser polarimetry measurements

被引:10
|
作者
Pons, ME
Rothman, RF
Ozden, RG
Liebmann, JM
Ritch, R
机构
[1] New York Eye & Ear Infirm, Dept Ophthalmol, Glaucoma Serv, New York, NY 10003 USA
[2] Wayne State Univ, Dept Ophthalmol, Detroit, MI USA
[3] New York Med Coll, Valhalla, NY 10595 USA
关键词
D O I
10.1016/S0002-9394(00)00814-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the effect of vitreous opacities on retinal nerve fiber layer retardation measurements obtained during scanning laser polarimetry. METHODS: Scanning laser polarimetry was performed in two eyes of two patients with vitreous opacities. RESULTS: The presence of a vitreous opacity within the measurement ellipse during scanning caused a marked, localized increase in polarization in the area of the opacity. This falsely increased the value obtained for the mean retinal nerve fiber layer thickness. Retinal nerve fiber layer thickness values were reduced when the opacity was not incorporated into the measurement ellipse. CONCLUSION: Artifact introduced by the presence of vitreous opacities can affect scanning laser polarimetry measurement reliability. (Am J Ophthalmol 2001;131: 511-513. (C) 2001 by Elsevier Science Inc. All rights reserved).
引用
收藏
页码:511 / 513
页数:3
相关论文
共 50 条
  • [1] Feasibility of Dynamic Video Scanning Laser Ophthalmoscopy for Evaluation of Vitreous Opacities
    Wagley, Sushant
    Ryan, Edwin H.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2022, 53 (12): : 714 - 716
  • [2] Scanning laser polarimetry (SLP) measurements following LASIK
    GursesOzden, R
    Barbieri, C
    Pons, M
    Buxton, D
    Liebmann, JM
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S660 - S660
  • [3] EFFECT OF VITREOUS OPACITIES ON STRAYLIGHT MEASUREMENTS
    Castilla-Marti, Miguel
    van den Berg, Tom J. T. P.
    de Smet, Marc D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (06): : 1240 - 1246
  • [4] Scan quality can affect Scanning Laser Polarimetry outcomes
    Vercellin, Alice Chandra Verticchio
    Milano, Giovanni
    Lombardo, Sara
    Raimondi, Marta
    Lanteri, Sara
    Cutolo, Carlo Alberto
    Bossolesi, Laura
    Rossi, Gemma
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Stability of corneal polarization axis measurements for scanning laser polarimetry
    Greenfield, DS
    Knighton, RW
    OPHTHALMOLOGY, 2001, 108 (06) : 1065 - 1069
  • [6] Stability of corneal polarization axis measurements for scanning laser polarimetry
    Greenfield, DS
    Knighton, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S287 - S287
  • [7] The effect of vitreous opacities on stray light measurements
    De Smet, M. D.
    Castilla, M.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [8] Scanning laser polarimetry measurements after laser-assisted in situ keratomileusis
    Gürses-Özden, R
    Pons, ME
    Barbieri, C
    Ishikawa, H
    Buxton, DF
    Liebmann, JM
    Ritch, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (04) : 461 - 464
  • [9] Laser Vitreolysis for Vitreous Opacities: A Prospective Study
    Ernest, Adam
    Veith, Miroslav
    Dite, Jakub
    Vranova, Jana
    Mojzis, Peter
    Pinero, David P.
    OPEN OPHTHALMOLOGY JOURNAL, 2024, 17
  • [10] The effect of posterior vitreous detachment or vitreous opacities (floaters) on straylight measurements
    Castilla, Miguel
    de Smet, Marc
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)