Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [41] Understanding coronary artery bypass transit time flow curves: role of bypass graft compliance
    Jelenc, Matija
    Jelenc, Blaz
    Klokocovnik, Tomislav
    Lakic, Nikola
    Gersak, Borut
    Knezevic, Ivan
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (02) : 164 - 168
  • [42] Evaluation of coronary artery bypass grafts by intraoperative transit time flow measurement
    Pankaj Goel
    S Dubey
    A Makker
    VM Kohli
    Indian Journal of Thoracic and Cardiovascular Surgery, 2003, 19 (2) : 108 - 112
  • [43] Body mass index and outcome after coronary artery bypass surgery
    Perrotta, S.
    Nilsson, F.
    Brandrup-Wognsen, G.
    Jeppsson, A.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2007, 48 (02): : 239 - 245
  • [44] What is a safe waiting time for coronary artery bypass surgery?
    Kee, F
    McDonald, P
    Kirwan, JR
    Patterson, CC
    Love, AHG
    QJM-MONTHLY JOURNAL OF THE ASSOCIATION OF PHYSICIANS, 1997, 90 (11): : 669 - 676
  • [45] Dual-Beam Ultrasound Versus Transit-Time Flow Meter for Intraoperative Graft Flow Measurement During Coronary Artery Bypass Grafting
    Shapira, Oz M.
    Eskenazi, Benjamin R.
    Hunter, Curtis T.
    Korach, Amit
    Anter, Elad
    Lazar, Harold L.
    Shemin, Richard J.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2006, 1 (03) : 131 - 136
  • [46] Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study
    Jokinen, Janne J.
    Werkkala, Kalervo
    Vainikka, Tiina
    Perakyla, Tarja
    Simpanen, Jarmo
    Ihlberg, Leo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 918 - 923
  • [47] Graft flow evaluation with intraoperative transit-time flow measurement in off-pump versus on-pump coronary artery bypass grafting
    Ben Leviner, Dror
    Rosati, Carlo Maria
    Similon, Miriam von Mucke
    Amabile, Andrea
    Thuijs, Daniel J. F. M.
    Di Giammarco, Gabriele
    Wendt, Daniel
    Trachiotis, Gregory D.
    Kieser, Teresa M.
    Kappetein, A. Pieter
    Head, Stuart J.
    Taggart, David P.
    Puskas, John D.
    JTCVS TECHNIQUES, 2022, 15 : 95 - 106
  • [48] Validation of a Transit Time Blood Flow Meter Used for Coronary Bypass Surgery
    Ortega-Palacios, R.
    Moreno, E.
    Leija, L.
    Vera, A.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 178 - 181
  • [49] Quality control of coronary bypass surgery: Intraoperative transit time flow measurement
    Walpoth, BH
    Walpoth, BN
    Mohadjer, A
    Gersbach, P
    Neidhart, P
    Althaus, U
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A7 - A7
  • [50] Cardiopulmonary bypass decreases pulmonary vascular resistance index after coronary artery bypass surgery
    Toikkanen, Vesa
    Rinne, Timo
    Huhtala, Heini
    Laurikka, Jari
    Porkkala, Helena
    Tarkka, Matti
    Niennander, Ari
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (01): : 37 - 43