Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [21] Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency
    Hatada A.
    Okamura Y.
    Kaneko M.
    Hisaoka T.
    Yamamoto S.
    Hiramatsu T.
    Nishimura Y.
    General Thoracic and Cardiovascular Surgery, 2011, 59 (1) : 14 - 18
  • [22] Intraoperative transit-time flow measurement and high-frequency ultrasound assessment in coronary artery bypass grafting
    Taggart, David P.
    Thuijs, Daniel J. F. M.
    Di Giammarco, Gabriele
    Puskas, John D.
    Wendt, Daniel
    Trachiotis, Gregory D.
    Kieser, Teresa M.
    Kappetein, A. Pieter
    Head, Stuart J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (04): : 1283 - 1291
  • [23] Fast Fourier transform analysis of intraoperative transit-time flow measurement during coronary artery bypass grafting
    Takami, Yoshiyuki
    Maekawa, Atsuo
    Yamana, Koji
    Akita, Kiyotoshi
    Amano, Kentaro
    Matsuhashi, Kazuki
    Niwa, Wakana
    Takagi, Yasushi
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [24] Evaluation of gastroepiploic arterial grafts to right coronary artery using transit-time flow measurement
    Uehara, Mayuko
    Muraki, Satoshi
    Takagi, Nobuyuki
    Yanase, Yosuke
    Tabuchi, Masaki
    Tachibana, Kazutoshi
    Miyaki, Yasuko
    Ito, Toshiro
    Kawaharada, Nobuyoshi
    Higami, Tetsuya
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (03) : 459 - 463
  • [25] LEFT CORONARY-ARTERY TRANSIT-TIME IN LATENT CORONARY HEART-DISEASE
    ERIKSSEN, J
    ENGE, I
    ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (04): : 385 - 391
  • [26] Graft control by transit time flow measurement and intraoperative angiography in coronary artery bypass surgery
    Hol, PK
    Fosse, E
    Mork, BE
    Lundblad, R
    Rein, KA
    Lingaas, PS
    Geiran, O
    Svennevig, JL
    Tonnessen, TI
    Nitter-Hauge, S
    Due-Tonnessen, P
    Vatne, K
    Smith, HJ
    HEART SURGERY FORUM, 2001, 4 (03): : 254 - 257
  • [27] Surgeon Judgment and Utility of Transit Time Flow Probes in Coronary Artery Bypass Grafting Surgery
    Quin, Jacquelyn
    Lucke, John
    Hattler, Brack
    Gupta, Sandeep
    Baltz, Janet
    Bishawi, Muath
    Almassi, G. Hossein
    Grover, Frederick L.
    Collins, Joseph
    Shroyer, A. Laurie
    JAMA SURGERY, 2014, 149 (11) : 1182 - 1187
  • [28] Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts
    Kieser, Teresa Mary
    Rose, Sarah
    Kowalewski, Ryszard
    Betenkie, Israel
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (02) : 155 - 161
  • [29] The Role of Color Doppler Ultrasonography in the Perioperative Period of Coronary Artery Bypass Grafting: Comparison with Transit-Time Flow Measurement
    Gao, Junxue
    Zhao, Zhou
    Zhu, Jiaan
    Tian, Hui
    Liu, Yuejie
    CARDIOLOGY, 2021, 146 (05) : 583 - 590
  • [30] Transit-time flow measurement cannot detect wrong anastomosis of an internal thoracic artery with the cardiac vein in coronary artery surgery
    Takami, Y
    Masumoto, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (04): : 629 - 631