Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [1] Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery (vol 37, pg 1063, 2010)
    Nordgaard, Havard B.
    Vitale, Nicola
    Astudillo, Rafael
    Renzulli, Attilio
    Romundstad, Pal
    Haaverstad, Rune
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (04) : 512 - 512
  • [2] Roles of Transit-Time Flow Measurement for Coronary Artery Bypass Surgery
    Takami, Yoshiyuki
    Takagi, Yasushi
    THORACIC AND CARDIOVASCULAR SURGEON, 2018, 66 (06): : 426 - 433
  • [3] Value of diastolic flow with transit-time flow meters in coronary artery bypass surgery
    Trachiotis, Gregory D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (03) : 431 - 431
  • [4] Transit-time flow measurement is essential in coronary artery bypass grafting
    Leong, DKH
    Ashok, V
    Nishkantha, A
    Shan, YH
    Sim, EKW
    ANNALS OF THORACIC SURGERY, 2005, 79 (03): : 854 - 858
  • [5] Transit-Time Flow Measurement and Outcomes in Coronary Artery Bypass Graft Patients
    Kim, Hyo-Hyun
    Kim, Jung-Hwan
    Lee, Seung Hyun
    Yoo, Kyung-Jong
    Youn, Young-Nam
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2023, 35 (02) : 217 - 227
  • [6] Transit-Time Blood Flow Measurements in Sequential Saphenous Coronary Artery Bypass Grafts
    Nordgaard, Havard
    Vitale, Nicola
    Haaverstad, Rune
    ANNALS OF THORACIC SURGERY, 2009, 87 (05): : 1409 - 1415
  • [7] A new way to use transit-time flow measurement for coronary artery bypass grafting
    Stastny, Lukas
    Kofler, Markus
    Zujs, Vitalijs
    Ruttmann, Elfriede
    Dumfarth, Julia
    Kilo, Juliane
    Brix, Alexandra
    Gasser, Simone
    Sakic, Adel
    Schachner, Thomas
    Grimm, Michael
    Bonaros, Nikolaos
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (05) : 711 - 718
  • [8] Intraoperative assessment of coronary artery bypass graft: Transit-time flowmetry versus angiography
    Shin, H
    Yozu, R
    Mitsumaru, A
    Iino, Y
    Hashizume, K
    Matayoshi, T
    Kawada, S
    ANNALS OF THORACIC SURGERY, 2001, 72 (05): : 1562 - 1565
  • [9] Intraoperative transit-time flow measurement in on-pump coronary artery bypass graft surgery: Single center experience
    Kaya, Ugur
    Colak, Abdurrahim
    Becit, Necip
    Ceviz, Munacettin
    Kocak, Hikmet
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 26 (02): : 167 - 176
  • [10] PREDICTORS OF HIGH AND LOW GRAFT FLOW FOR ISOLATED CORONARY ARTERY BYPASS GRAFTS USING TRANSIT-TIME FLOWMETRY
    Forcillo, J.
    Noiseux, N.
    Dubois, M. J.
    Mansour, S.
    Prieto, I.
    Basile, F.
    Stevens, L. M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S255 - S255