Manual and computer-aided space analysis: A comparative study

被引:62
|
作者
Schirmer, UR [1 ]
Wiltshire, WA [1 ]
机构
[1] Univ Pretoria, Fac Dent, Dept Orthodont, ZA-0002 Pretoria, South Africa
关键词
D O I
10.1016/S0889-5406(97)70234-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Recently, computers have been used to measure key landmarks from photocopies of upper and lower study models to increase simplicity, accuracy, and informatics. This is a comparative study to evaluate the accuracy and reliability of computer-aided space analysis. Data were collected from a series of randomly selected study models. All subjects had Angle Glass I molar relationships with minor malocclusions such as crowding, rotations, or diastemas. Two investigators independently measured teeth on models with a Vernier gauge that had sharpened caliper tips. Intraexaminer and interexaminer reliability was determined at 0.2 mm. All teeth, to and including the first molars, were measured. Two photocopies of each set of models were made on a photostat machine (Xerox, Japan) and were coded. A template with a ruler was used, to allow the investigator to compensate for any reduction or enlargement error during the photocopying process. The mesiodistal sizes were measured with a digitizer, and results were processed by using a dedicated computer program. Evaluations were done in a double-blind manner. The nonparametric Wilcoxon signed rank test for paired observations to compare median differences between measurements was used. Intraexaminer digitized measurements were almost identical and differed (p < 0.0001) for only one measurement. However, interexaminer manual and digitized measurements differed significantly (p < 0.001) for 20 of the 24 teeth. Nineteen of these digitized tooth measurements were smaller. The mean arch length measurements differed by 4.7 mm (p < 0.0001) in the maxilla and by 3.1 mm (p < 0.0001) in the mandible. The difference between the manual and digitized analyses may be due to the photocopying process. The inability to accurately measure a three-dimensional study cast that has been duplicated in two dimensions, convex structure of teeth, curve of Spee, tooth inclination, and tooth position may play a role. The computer-aided measuring system is reliable, but accurate mesiodistal measurements cannot be made from photocopies of dental models. Manual measurements that use a calibrated gauge produce the most accurate, reliable, and reproducible results.
引用
收藏
页码:676 / 680
页数:5
相关论文
共 50 条
  • [31] Computer-aided analysis and quantitative study of complex Ichnofabrics
    Qi, Yong'an
    Wang, Min
    Liu, Yonghe
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 3, 2008, : 544 - 547
  • [32] Study on computer-aided reliability design and analysis system
    Zhao, Tingdi
    Zeng, Shengkui
    Kang, Rui
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2000, 21 (03): : 206 - 209
  • [33] The feasibility of using manual segmentation in a multifeature computer-aided diagnosis system for classification of skin lesions: a retrospective comparative study
    Chang, Wen-Yu
    Huang, Adam
    Chen, Yin-Chun
    Lin, Chi-Wei
    Tsai, John
    Yang, Chung-Kai
    Huang, Yin-Tseng
    Wu, Yi-Fan
    Chen, Gwo-Shing
    BMJ OPEN, 2015, 5 (04):
  • [34] Computer-Aided Architecting of Disaggregated Space Systems
    Thompson, Robert
    Colombi, John
    Black, Jonathan
    2014 IEEE AEROSPACE CONFERENCE, 2014,
  • [35] STRUCTURAL-ANALYSIS OF SPACE IMAGERY VIA COMPUTER-AIDED INTERPRETATION
    KORONOVSKII, NV
    ZLATOPOLSKII, AA
    IVANCHENKO, GN
    SOVIET JOURNAL OF REMOTE SENSING, 1990, 6 (01): : 114 - 121
  • [36] Reproducibility and influence of hand rotation on computer-aided joint space analysis
    Pfeil, Alexander
    Hansch, Andreas
    Sommerfeld, Julia
    Froeber, Rosemarie
    Renz, Diane M.
    Lehmann, Gabriele
    Malich, Ansgar
    Wolf, Gunter
    Boettcher, Joachim
    JOINT BONE SPINE, 2012, 79 (04) : 384 - 388
  • [37] The usefulness of computer-aided joint space analysis in the assessment of rheumatoid arthritis
    Pfeil, Alexander
    Renz, Diane M.
    Hansch, Andreas
    Kainberger, Franz
    Lehmann, Gabriele
    Malich, Ansgar
    Wolf, Gunter
    Boettcher, Joachim
    JOINT BONE SPINE, 2013, 80 (04) : 380 - 385
  • [38] Computer-aided comparative chorology of neotropical plants
    Morawetz, W
    Kragel, P
    TROPICAL PHYOTOGEOGRAPHY: REALITIES AND PERSPECTIVES, 1996, : 217 - +
  • [39] A comparative analysis of computer-aided design team performance with collaboration software
    Eves K.
    Salmon J.
    Olsen J.
    Fagergren F.
    Computer-Aided Design and Applications, 2018, 15 (04): : 476 - 487
  • [40] Comparison of manual and computer-aided breast cancer biopsy grading
    Schnorrenberg, F
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1166 - 1167