The use radichromic film for tornotherapy IMRT dosimetric verification

被引:0
|
作者
Turian, J. [1 ]
Khelashvili, G. [1 ]
Chu, J. [1 ]
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60612 USA
关键词
D O I
10.1118/1.2761142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the adequacy of radiochromic_film/CCD‐flatbed scanner system as a tool for tomotherapy IMRT delivery verification. Methods and Materials: In this study, EBT Gafchromic film and Epson flatbed scanner were used. IMRT plans created using tomotherapy treatment planning were delivered to a phantom which incorporates the film and ion chamber. To obtain accurate and reproducible results a film protocol was setup. First the scanner was evaluated in terms of OD variations due to film position on the scanner, direction of film relative to the motion of CCD‐array, and temperature of the glass during read out. From preliminary findings, a simple protocol was developed in which each film was scanned pre/post irradiation in the same position and orientation. The time between exposure and scan was ⩾ 6 hrs. This protocol is applicable for doses ranging from 0–300 cGy. For scanning, 48‐bit RGB mode was employed and the resolution set to 72 dpi. From the resulting TIFF‐images, the red channel images were extracted, filtered, and analyzed using an in‐house film dosimetry software. Since the pre and post irradiation images were co‐registered, the background was subtracted point by point and the pixel value converted to OD. The measured dose distributions were compared with values calculated by tomotherapy at the location of the film. Comparison between measured and calculated dose distributions is expressed using the γ‐index. Results: The measured dose uncertainty with this protocol is +/− 2.0%. A 2D correction matrix was obtained to account for the nonuniformities of the film, light source, glass plates, and CCD array. For the distributions compared, the passing rates γ ⩽1.0 were larger than 90%. Conclusion: The use of Gafchromic film and an Epson scanner in conjunction with a proper scanning protocol provides an accurate and efficient tool for dosimetric verification of IMRT fields produced by serial tomotherapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2497 / 2498
页数:2
相关论文
共 50 条
  • [1] Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification
    Borca, Valeria Casanova
    Pasquino, Massimo
    Russo, Giuliana
    Grosso, Pierangelo
    Cante, Domenico
    Sciacero, Piera
    Girelli, Giuseppe
    La Porta, Maria Rosa
    Tofani, Santi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 158 - 171
  • [2] Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    Chuang, CF
    Verhey, LJ
    Xia, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1109 - 1115
  • [3] IMRT DOSIMETRIC VERIFICATION PROCEDURE
    Pellejero, S.
    Lozares, S.
    Forner, A.
    Iriondo, U.
    Otal, A.
    Soto, P. M.
    Maneru, F.
    Martin-Albina, M. L.
    Miquelez, S.
    Rubio, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S512 - S512
  • [4] Quantitative dosimetric verification for IMRT
    Narita, Y
    Hatano, K
    Sakai, M
    Araki, H
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S105 - S105
  • [5] Dosimetric verification of biologically adapted IMRT
    Rodal, Jan
    Waldeland, Einar
    Sovik, Aste
    Malinen, Eirik
    Rodal, Jan
    Sovik, Aste
    MEDICAL PHYSICS, 2011, 38 (05) : 2586 - 2594
  • [6] Dosimetric Verification of IMRT Fields Using GafChromic® EBT-2 Film
    McLawhorn, R.
    Ter-Antonyan, R.
    Benedict, S.
    Wijesooriya, K.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [7] Design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatments
    Grams, Michael P.
    de los Santos, Luis E. Fong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 59 - 65
  • [8] Statistical process control for IMRT dosimetric verification
    Breen, Stephen L.
    Moseley, Douglas J.
    Zhang, Beibei
    Sharpe, Michael B.
    MEDICAL PHYSICS, 2008, 35 (10) : 4417 - 4425
  • [9] Dosimetric verification needs for conformal therapy and IMRT
    Fraass, B
    Moran, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1358 - 1358
  • [10] Characterization and use of EBT radiochromic film for IMRT dose verification
    Zeidan, O.
    Stephenson, S.
    Meeks, S.
    Willoughby, T.
    Wagner, T.
    Kupelian, P.
    Langen, K.
    MEDICAL PHYSICS, 2006, 33 (06) : 2077 - 2077