Statistical process control for IMRT dosimetric verification

被引:65
|
作者
Breen, Stephen L. [1 ,2 ]
Moseley, Douglas J. [1 ,2 ]
Zhang, Beibei [1 ]
Sharpe, Michael B. [1 ,2 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Fac Med, Toronto, ON M5S 3E2, Canada
关键词
D O I
10.1118/1.2975144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient-specific measurements are typically used to validate the dosimetry of intensity-modulated radiotherapy (IMRT). To evaluate the dosimetric performance over time of our IMRT process, we have used statistical process control (SPC) concepts to analyze the measurements from 330 head and neck (H&N) treatment plans. The objectives of the present work are to: (i) Review the dosimetric measurements of a large series of consecutive head and neck treatment plans to better understand appropriate dosimetric tolerances; (ii) analyze the results with SPC to develop action levels for measured discrepancies; (iii) develop estimates for the number of measurements that are required to describe IMRT dosimetry in the clinical setting; and (iv) evaluate with SPC a new beam model in our planning system. H&N IMRT cases were planned with the PINNACLE3 treatment planning system versions 6.2b or 7.6c (Philips Medical Systems, Madison, WI) and treated on Varian (Palo Alto, CA) or Elekta (Crawley, UK) linacs. As part of regular quality assurance, plans were recalculated on a 20-cm-diam cylindrical phantom, and ion chamber measurements were made in high-dose volumes (the PTV with highest dose) and in low-dose volumes (spinal cord organ-at-risk, OR). Differences between the planned and measured doses were recorded as a percentage of the planned dose. Differences were stable over time. Measurements with PINNACLE(3) 6.2b and Varian linacs showed a mean difference of 0.6% for PTVs (n=149, range, -4.3% to 6.6%), while OR measurements showed a larger systematic discrepancy (mean 4.5%, range -4.5% to 16.3%) that was due to well-known limitations of the MLC model in the earlier version of the planning system. Measurements with PINNACLE(3) 7.6c and Varian linacs demonstrated a mean difference of 0.2% for PTVs (n=160, range, -3.0%, to 5.0%) and -1.0% for ORs (range -5.8% to 4.4%). The capability index (ratio of specification range to range of the data) was 1.3 for the PTV data, indicating that almost all measurements were within +/- 5%. We have used SPC tools to evaluate a new beam model in our planning system to produce a systematic difference of -0.6% for PTVs and 0.4% for ORs, although the number of measurements is smaller (n=25). Analysis of this large series of H&N IMRT measurements demonstrated that our IMRT dosimetry was stable over time and within accepted tolerances. These data provide useful information for assessing alterations to beam models in the planning system. IMRT is enhanced by the addition of statistical process control to traditional quality control procedures. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4417 / 4425
页数:9
相关论文
共 50 条
  • [1] IMRT DOSIMETRIC VERIFICATION PROCEDURE
    Pellejero, S.
    Lozares, S.
    Forner, A.
    Iriondo, U.
    Otal, A.
    Soto, P. M.
    Maneru, F.
    Martin-Albina, M. L.
    Miquelez, S.
    Rubio, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S512 - S512
  • [2] Quantitative dosimetric verification for IMRT
    Narita, Y
    Hatano, K
    Sakai, M
    Araki, H
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S105 - S105
  • [3] Dosimetric verification of biologically adapted IMRT
    Rodal, Jan
    Waldeland, Einar
    Sovik, Aste
    Malinen, Eirik
    Rodal, Jan
    Sovik, Aste
    MEDICAL PHYSICS, 2011, 38 (05) : 2586 - 2594
  • [4] Statistical process control for IMRT quality assurance
    Pawlicki, T
    Whitaker, M
    Price, RA
    Boyer, AL
    MEDICAL PHYSICS, 2003, 30 (06) : 1351 - 1351
  • [5] Dosimetric verification needs for conformal therapy and IMRT
    Fraass, B
    Moran, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1358 - 1358
  • [6] Quantitative dosimetric verification of an IMRT planning and delivery system
    Low, DA
    Mutic, S
    Dempsey, JF
    Gerber, RL
    Bosch, WR
    Perez, CA
    Purdy, JA
    RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) : 305 - 316
  • [7] Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    Chuang, CF
    Verhey, LJ
    Xia, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1109 - 1115
  • [8] Dosimetric verification of IMRT delivery: Varian, Siemens, and Elekta
    Willcut, V
    Newman, F
    Zhu, X
    Low, D
    Percy, J
    Cain, M
    Markman, J
    Munger, T
    Nelms, B
    MEDICAL PHYSICS, 2002, 29 (06) : 1365 - 1365
  • [9] Application of statistical process control to IMRT quality assurance
    Fang, B.
    Shoale, J.
    Pawlicki, T.
    Boyer, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2071 - 2071
  • [10] Implementation of IMRT treatment: verification of dosimetric and geometric accuracy
    Korevaar, EW
    Davis, JB
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 119 - 119