Statistical process control for IMRT dosimetric verification

被引:67
|
作者
Breen, Stephen L. [1 ,2 ]
Moseley, Douglas J. [1 ,2 ]
Zhang, Beibei [1 ]
Sharpe, Michael B. [1 ,2 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Fac Med, Toronto, ON M5S 3E2, Canada
关键词
D O I
10.1118/1.2975144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient-specific measurements are typically used to validate the dosimetry of intensity-modulated radiotherapy (IMRT). To evaluate the dosimetric performance over time of our IMRT process, we have used statistical process control (SPC) concepts to analyze the measurements from 330 head and neck (H&N) treatment plans. The objectives of the present work are to: (i) Review the dosimetric measurements of a large series of consecutive head and neck treatment plans to better understand appropriate dosimetric tolerances; (ii) analyze the results with SPC to develop action levels for measured discrepancies; (iii) develop estimates for the number of measurements that are required to describe IMRT dosimetry in the clinical setting; and (iv) evaluate with SPC a new beam model in our planning system. H&N IMRT cases were planned with the PINNACLE3 treatment planning system versions 6.2b or 7.6c (Philips Medical Systems, Madison, WI) and treated on Varian (Palo Alto, CA) or Elekta (Crawley, UK) linacs. As part of regular quality assurance, plans were recalculated on a 20-cm-diam cylindrical phantom, and ion chamber measurements were made in high-dose volumes (the PTV with highest dose) and in low-dose volumes (spinal cord organ-at-risk, OR). Differences between the planned and measured doses were recorded as a percentage of the planned dose. Differences were stable over time. Measurements with PINNACLE(3) 6.2b and Varian linacs showed a mean difference of 0.6% for PTVs (n=149, range, -4.3% to 6.6%), while OR measurements showed a larger systematic discrepancy (mean 4.5%, range -4.5% to 16.3%) that was due to well-known limitations of the MLC model in the earlier version of the planning system. Measurements with PINNACLE(3) 7.6c and Varian linacs demonstrated a mean difference of 0.2% for PTVs (n=160, range, -3.0%, to 5.0%) and -1.0% for ORs (range -5.8% to 4.4%). The capability index (ratio of specification range to range of the data) was 1.3 for the PTV data, indicating that almost all measurements were within +/- 5%. We have used SPC tools to evaluate a new beam model in our planning system to produce a systematic difference of -0.6% for PTVs and 0.4% for ORs, although the number of measurements is smaller (n=25). Analysis of this large series of H&N IMRT measurements demonstrated that our IMRT dosimetry was stable over time and within accepted tolerances. These data provide useful information for assessing alterations to beam models in the planning system. IMRT is enhanced by the addition of statistical process control to traditional quality control procedures. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4417 / 4425
页数:9
相关论文
共 50 条
  • [21] New Dosimetric Treatment Verification System of IMRT using a COMPASS, Clinical Experience and Dosimetric Properties
    Nakaguchi, Y.
    Araki, F.
    Saiga, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S767 - S767
  • [22] Dosimetric Verification of Dynamic IMRT Plans Using I'mRT MatriXX
    Oinam, A. S.
    Singh, Lakhwant
    Goswami, P.
    Sharma, S. C.
    Ghoshal, S.
    Kapoor, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] APPLICATION OF GAFCHROMIC EBT FILMS TO DOSIMETRIC VERIFICATION OF DOSE DISTRIBUTIONS IN IMRT
    Chelminski, K.
    Bulski, W.
    Georg, D.
    Bodzak, D.
    Maniakowski, Z.
    Oborska, D.
    Rostkowska, J.
    Kania, M.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : XXI - XXI
  • [24] A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)
    Gerard, Karine
    Grandhaye, Jean-Pierre
    Marchesi, Vincent
    Kafrouni, Hanna
    Husson, Francois
    Aletti, Pierre
    MEDICAL PHYSICS, 2009, 36 (04) : 1275 - 1285
  • [25] The effect of segment numbers on dosimetric verification of IMRT fields obtained by the static IMRT (step and shoot) method
    Acun, Hediye
    Kemikler, Gonul
    Cakir, Aydin
    Kemikler Tuncay, Ebru
    Agaoglu, Fulya
    Darendeliler, Emin
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2011, 26 (01): : 18 - 25
  • [26] MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
    Chen, LL
    Price, RA
    Wang, L
    Li, JS
    Qin, LH
    McNeeley, S
    Ma, CMC
    Freedman, GM
    Pollack, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 636 - 647
  • [27] Statistical Process Control and Independent MU Calculations as a Surrogate for IMRT QA Measurements
    Shoales, J.
    Fang, B.
    Weinberg, R.
    Montanaro, P.
    Boyer, A.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience
    van Zijtveld, Mathilda
    Dirkx, Maarten L. P.
    de Boer, Hans C. J.
    Heijmen, Ben J. M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (02) : 168 - 175
  • [29] Design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatments
    Grams, Michael P.
    de los Santos, Luis E. Fong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 59 - 65
  • [30] Dosimetric Verification of IMRT Fields Using GafChromic® EBT-2 Film
    McLawhorn, R.
    Ter-Antonyan, R.
    Benedict, S.
    Wijesooriya, K.
    MEDICAL PHYSICS, 2010, 37 (06)