Inter-Session Repeatability of Retinal Layer Thickness in Optical Coherence Tomography

被引:0
|
作者
DeBuc, D. Cabrera [1 ]
Tian, Jing [1 ]
Bates, Nathan [1 ]
Somfai, Gabor Mark [2 ,3 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Coral Gables, FL 33124 USA
[2] Pallas Kliniken, Retinol Unit, Olten, Switzerland
[3] Semmelweis Univ, Dept Ophthalmol, Fac Med, Budapest, Hungary
关键词
Optical coherence tomography; repeatability; registration; retinal layer thickness; segmentation;
D O I
10.1117/12.2254640
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Reliable retinal layer thickness measurements using optical coherence tomography (OCT) are important to track the subtle retinal changes in longitudinal studies. A total of 10 eyes (5 healthy subjects, 40 +/- 13 years old) were enrolled to study the inter-session repeatability and identify the pitfalls affecting the reliabilities. Each eye was scanned using spectral domain OCT (Spectralis SDOCT, Heidelberg Engineering) for 3 sessions with 30 seconds rest in between. The first and second sessions were scanned independently and the third one was scanned with the first one as the baseline visit. Each session consisted of a confocal scanning laser ophthalmoscopy (cSLO) image and 61 B-scans of 496x768 pixels. The first, second and third sessions were named as baseline, unregistered and registered sessions; respectively. Seven retinal layers labeled as RNFL, GCL+IPL, INL, OPL, ONL, IS and OS were segmented using a custom software (OCTRIMA3D) and measured in the ETDRS grid. Inter-session standard deviation (sigma), coefficient of repeatability (CR) and coefficient of variations (COV) were calculated to quantify the repeatability. Paired t-test of COVs was used to compare the repeatability and the level of significance was set at 5%. We obtained that values of the CR > 5 mu m and COV of 5%, were revealed only in the outer layers. The values of COV were not significantly different (p< 0.05) in the unregistered scanning session. Our results show that the rotations in the unregistered scanning sessions do not cause significant change in repeatability.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Evaluation of Retinal and Choroidal Thickness by Swept-Source Optical Coherence Tomography: Repeatability and Assessment of Artifacts
    Mansouri, Kaweh
    Medeiros, Felipe A.
    Tatham, Andrew J.
    Marchase, Nicholas
    Weinreb, Robert N.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) : 1022 - 1032
  • [22] Repeatability and Reproducibility of Retinal Thickness Measurements by Optical Coherence Tomography in Age-Related Macular Degeneration
    Krebs, Ilse
    Hagen, Stefan
    Brannath, Werner
    Haas, Paulina
    Womastek, Irene
    de Salvo, Gabriella
    Ansari-Shahrezaei, Siamak
    Binder, Susanne
    [J]. OPHTHALMOLOGY, 2010, 117 (08) : 1577 - 1584
  • [23] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [24] Assessment of Macula and Retinal Nerve Fiber Layer Thickness with Optical Coherence Tomography in Myopia
    Ozkagnici, Ahmet
    Tokgoz, Mine
    [J]. TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2012, 32 (02): : 415 - 427
  • [25] Characteristics of retinal layer thickness in acute anterior uveitis: an optical coherence tomography study
    Lee, Min-Woo
    Lee, Taek-Hoon
    Won, Yeo-Kyoung
    Shin, Yong-Il
    Kim, Jung-Yeul
    [J]. ACTA OPHTHALMOLOGICA, 2020, 98 (01) : E50 - E55
  • [26] Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma
    Wollstein, G
    Schuman, JS
    Price, LL
    Aydin, A
    Stark, PC
    Hertzmark, E
    Lai, E
    Ishikawa, H
    Mattox, C
    Fujimoto, JG
    Paunescu, LA
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (04) : 464 - 470
  • [27] A new algorithm for retinal nerve fiber layer thickness measurement by optical coherence tomography
    Huang, D
    Hee, MR
    PedutKloizman, T
    Wilkins, JR
    Coker, JG
    Puliafito, CA
    Fujimoto, JG
    Schuman, JS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5040 - 5040
  • [28] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [29] Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography
    Salchow, DJ
    Oleynikov, YS
    Chiang, MF
    Kennedy-Salchow, SE
    Langton, K
    Tsai, JC
    Al-Aswad, LA
    [J]. OPHTHALMOLOGY, 2006, 113 (05) : 786 - 791
  • [30] Assesment of the Retinal Nerve Fiber Layer Thickness with Optical Coherence Tomography in Patients with Psoriasis
    Rifaioglu, Emine Nur
    Tuzcu, Esra Ayhan
    Sen, Bilge Bubul
    Ekiz, Ozlem
    [J]. TURK DERMATOLOJI DERGISI-TURKISH JOURNAL OF DERMATOLOGY, 2014, 8 (04): : 202 - 205