Inter-Session Repeatability of Retinal Layer Thickness in Optical Coherence Tomography

被引:0
|
作者
DeBuc, D. Cabrera [1 ]
Tian, Jing [1 ]
Bates, Nathan [1 ]
Somfai, Gabor Mark [2 ,3 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Coral Gables, FL 33124 USA
[2] Pallas Kliniken, Retinol Unit, Olten, Switzerland
[3] Semmelweis Univ, Dept Ophthalmol, Fac Med, Budapest, Hungary
关键词
Optical coherence tomography; repeatability; registration; retinal layer thickness; segmentation;
D O I
10.1117/12.2254640
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Reliable retinal layer thickness measurements using optical coherence tomography (OCT) are important to track the subtle retinal changes in longitudinal studies. A total of 10 eyes (5 healthy subjects, 40 +/- 13 years old) were enrolled to study the inter-session repeatability and identify the pitfalls affecting the reliabilities. Each eye was scanned using spectral domain OCT (Spectralis SDOCT, Heidelberg Engineering) for 3 sessions with 30 seconds rest in between. The first and second sessions were scanned independently and the third one was scanned with the first one as the baseline visit. Each session consisted of a confocal scanning laser ophthalmoscopy (cSLO) image and 61 B-scans of 496x768 pixels. The first, second and third sessions were named as baseline, unregistered and registered sessions; respectively. Seven retinal layers labeled as RNFL, GCL+IPL, INL, OPL, ONL, IS and OS were segmented using a custom software (OCTRIMA3D) and measured in the ETDRS grid. Inter-session standard deviation (sigma), coefficient of repeatability (CR) and coefficient of variations (COV) were calculated to quantify the repeatability. Paired t-test of COVs was used to compare the repeatability and the level of significance was set at 5%. We obtained that values of the CR > 5 mu m and COV of 5%, were revealed only in the outer layers. The values of COV were not significantly different (p< 0.05) in the unregistered scanning session. Our results show that the rotations in the unregistered scanning sessions do not cause significant change in repeatability.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Inter-Session Repeatability of Retinal Layer Thickness Measurements in Optical Coherence Tomography
    Tian, Jing
    Bates, Nathan
    Somfai, Gabor Mark
    DeBuc, Delia
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Automated Retinal Layer Segmentation Using Spectral Domain Optical Coherence Tomography: Evaluation of Inter-Session Repeatability and Agreement between Devices
    Terry, Louise
    Cassels, Nicola
    Lu, Kelly
    Acton, Jennifer H.
    Margrain, Tom H.
    North, Rachel V.
    Fergusson, James
    White, Nick
    Wood, Ashley
    [J]. PLOS ONE, 2016, 11 (09):
  • [3] The Repeatability of Retinal Layer Thickness Measurements with Spectral-Domain Optical Coherence Tomography in Normal Eyes
    Kang, Min Seok
    Yu, Seung-Young
    Kwak, Hyung Woo
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 786 - 793
  • [4] Thickness of the Macula, Retinal Nerve Fiber Layer, and Ganglion Cell Layer in the Epiretinal Membrane: The Repeatability Study of Optical Coherence Tomography
    Lee, Haeng-Jin
    Kim, Min-Su
    Jo, Young-Joon
    Kim, Jung-Yeul
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4554 - 4559
  • [5] Repeatability of retinal thickness measurements in children using spectral domain optical coherence tomography
    Boned-Murillo, Ana
    Garcia, Diana Perez
    Diaz, Maria Dolores
    Cano, Ana Sanchez
    Remon, Leon
    Hospital, Elvira Orduna
    Fernandez-Espinosa, Guisela
    Pinilla, Maria Sopena
    Rivases, Guillermo Perez
    Lozano, Isabel Pinilla
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100
  • [6] Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices
    Matlach, Juliane
    Wagner, Martin
    Malzahn, Uwe
    Goebel, Winfried
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6536 - 6546
  • [7] Inter-session repeatability of markerless motion capture gait kinematics
    Kanko, Robert M.
    Laende, Elise
    Selbie, W. Scott
    Deluzio, Kevin J.
    [J]. JOURNAL OF BIOMECHANICS, 2021, 121
  • [8] Inter-session repeatability of cortical excitability measurements in patients with epilepsy
    Badawy, Radwa A. B.
    Jackson, Graeme D.
    Berkovic, Samuel F.
    Macdonell, Richard A. L.
    [J]. EPILEPSY RESEARCH, 2012, 98 (2-3) : 182 - 186
  • [9] CONCURRENT ASSESSMENT AND INTER-SESSION REPEATABILITY OF MARKERLESS MOTION CAPTURE
    Carbajal-Mendez, Hector A.
    Hammond, Eric
    Johnson, Joshua
    Schultz, Brooke
    Luke, Anthony
    Souza, Richard
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2024, 32 : S174 - S174
  • [10] Repeatability and Reproducibility of Retinal Thickness Measurements in Diabetic Patients with Spectral Domain Optical Coherence Tomography
    Fiore, Tito
    Androudi, Sofia
    Iaccheri, Barbara
    Lupidi, Marco
    Fabrizio, Giansanti
    Fruttini, Daniela
    Biondi, Laura
    Cagini, Carlo
    [J]. CURRENT EYE RESEARCH, 2013, 38 (06) : 674 - 679