Automated Retinal Layer Segmentation Using Spectral Domain Optical Coherence Tomography: Evaluation of Inter-Session Repeatability and Agreement between Devices

被引:49
|
作者
Terry, Louise [1 ]
Cassels, Nicola [1 ]
Lu, Kelly [1 ]
Acton, Jennifer H. [1 ]
Margrain, Tom H. [1 ]
North, Rachel V. [1 ]
Fergusson, James [1 ,2 ]
White, Nick [1 ,2 ]
Wood, Ashley [1 ]
机构
[1] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff, S Glam, Wales
[2] Cardiff Univ, Vis Sci Bioimaging Labs, Cardiff, S Glam, Wales
来源
PLOS ONE | 2016年 / 11卷 / 09期
基金
英国医学研究理事会;
关键词
MACULAR THICKNESS MEASUREMENTS; NERVE-FIBER; SD-OCT; IMAGE-ANALYSIS; REPRODUCIBILITY; DEGENERATION; EYES; CLASSIFICATION; FUNDUS; SIZE;
D O I
10.1371/journal.pone.0162001
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Retinal and intra-retinal layer thicknesses are routinely generated from optical coherence tomography (OCT) images, but on-board software capabilities and image scaling assumptions are not consistent across devices. This study evaluates the device-independent Iowa Reference Algorithms ( Iowa Institute for Biomedical Imaging) for automated intra-retinal layer segmentation and image scaling for three OCT systems. Healthy participants (n = 25) underwent macular volume scans using a Cirrus HD-OCT (Zeiss), 3D-OCT 1000 (Topcon), and a non-commercial long-wavelength (1040nm) OCT on two occasions. Mean thickness of 10 intra-retinal layers was measured in three ETDRS subfields ( fovea, inner ring and outer ring) using the Iowa Reference Algorithms. Where available, total retinal thicknesses were measured using on-board software. Measured axial eye length (AEL)-dependent scaling was used throughout, with a comparison made to the system-specific fixed-AEL scaling. Inter-session repeatability and agreement between OCT systems and segmentation methods was assessed. Inter-session coefficient of repeatability (CoR) for the foveal subfield total retinal thickness was 3.43 mu m, 4.76 mu m, and 5.98 mu m for the Zeiss, Topcon, and long-wavelength images respectively. For the commercial software, CoR was 4.63 mu m (Zeiss) and 7.63 mu m (Topcon). The Iowa Reference Algorithms demonstrated higher repeatability than the on-board software and, in addition, reliably segmented all 10 intra-retinal layers. With fixed-AEL scaling, the algorithm produced significantly different thickness values for the three OCT devices (P<0.05), with these discrepancies generally characterized by an overall offset (bias) and correlations with axial eye length for the foveal subfield and outer ring (P<0.05). This correlation was reduced to an insignificant level in all cases when AEL-dependent scaling was used. Overall, the Iowa Reference Algorithms are viable for clinical and research use in healthy eyes imaged with these devices, however ocular biometry is required for accurate quantification of OCT images.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Inter-Session Repeatability of Retinal Layer Thickness in Optical Coherence Tomography
    DeBuc, D. Cabrera
    Tian, Jing
    Bates, Nathan
    Somfai, Gabor Mark
    [J]. MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [2] Inter-Session Repeatability of Retinal Layer Thickness Measurements in Optical Coherence Tomography
    Tian, Jing
    Bates, Nathan
    Somfai, Gabor Mark
    DeBuc, Delia
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Fast retinal layer segmentation of spectral domain optical coherence tomography images
    Zhang, Tianqiao
    Song, Zhangjun
    Wang, Xiaogang
    Zheng, Huimin
    Jia, Fucang
    Wu, Jianhuang
    Jia, Fucang
    Wu, Jianhuang
    Li, Guanglin
    Hu, Qingmao
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (09)
  • [4] Comparison of retinal layer profiles between spectral-domain optical coherence tomography devices
    Hu, Zhihong
    Hariri, Amirhossein
    Wu, Xiaodong
    Sadda, Srinivas R.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Retinal Layer Segmentation in Patients with Multiple Sclerosis Using Spectral Domain Optical Coherence Tomography
    Garcia-Martin, Elena
    Polo, Vicente
    Larrosa, Jose M.
    Marques, Marcia L.
    Herrero, Raquel
    Martin, Jesus
    Ara, Jose R.
    Fernandez, Javier
    Pablo, Luis E.
    [J]. OPHTHALMOLOGY, 2014, 121 (02) : 573 - 579
  • [6] Agreement Between Spectral Domain Optical Coherence Tomography and Retinal Nerve Fiber Layer Photography in Chinese
    Wu, Xi-Shi
    Xu, Liang
    Jonas, Jost B.
    Zhang, Li
    Yang, Hua
    Chen, Chang-Xi
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (04) : 228 - 233
  • [7] Automated segmentation of retinal blood vessels in spectral domain optical coherence tomography scans
    Pilch, Matthaeus
    Wenner, Yaroslava
    Strohmayr, Elisabeth
    Preising, Markus
    Friedburg, Christoph
    Bexten, Erdmuthe Meyer Zu
    Lorenz, Birgit
    Stieger, Knut
    [J]. BIOMEDICAL OPTICS EXPRESS, 2012, 3 (07): : 1478 - 1491
  • [8] Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices
    Matlach, Juliane
    Wagner, Martin
    Malzahn, Uwe
    Goebel, Winfried
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6536 - 6546
  • [9] Agreement, repeatability, and reproducibility of quantitative retinal layer assessment using swept-source and spectral-domain optical coherence tomography in eyes with retinal diseases
    Hou, Huiyuan
    Durbin, Mary K.
    El-Nimri, Nevin
    Fischer, Jeffrey L.
    Sadda, Srinivas R.
    [J]. FRONTIERS IN MEDICINE, 2023, 10
  • [10] Repeatability of retinal thickness measurements in children using spectral domain optical coherence tomography
    Boned-Murillo, Ana
    Garcia, Diana Perez
    Diaz, Maria Dolores
    Cano, Ana Sanchez
    Remon, Leon
    Hospital, Elvira Orduna
    Fernandez-Espinosa, Guisela
    Pinilla, Maria Sopena
    Rivases, Guillermo Perez
    Lozano, Isabel Pinilla
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100