Fast DC Fault Current Suppression and Fault Ride-Through in Full-Bridge MMCs via Reverse SM Capacitor Discharge

被引:0
|
作者
Sakib, Munif Nazmus [1 ]
Azad, Sahar Pirooz [1 ]
Kazerani, Mehrdad [1 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, 200 Univ Ave W, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
modular multilevel converter (MMC); DC fault blocking submodule (SM); high voltage direct current (HVDC) transmission; fault ride-through (FRT); static synchronous compensator (STATCOM); bipolar SM; MODULAR MULTILEVEL CONVERTER; SYSTEMS; COORDINATION; PROTECTION; OPERATION; BLOCKING; CELLS;
D O I
10.3390/en15134595
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the event of a DC side fault in modular multilevel converters (MMCs), the fault current contributions are initially made by submodule (SM) capacitor discharge, which occurs before the fault is detected, followed by the AC side contribution to the DC side fault. While the AC side currents can be regulated using fault blocking SMs, the initial discharge of the SM capacitors results in high DC fault currents, which can take several milliseconds to be brought under control. This paper presents a method to actively control the rate of rise of the DC fault current by regulating the discharge of SM capacitors and accelerating the suppression of fault current oscillations during fault ride-through (FRT) in a full-bridge (FB)-MMC system. In the proposed method, the discharge direction of the FBSM capacitors is reversed following the detection of a DC side fault, which leads to a reversal in the fault current direction and a fast drop-off towards the zero-crossing. Immediately after the zero-crossing of the DC fault current, the DC fault is cleared by adjusting the arm voltage references and operating the MMC as a static synchronous compensator (STATCOM) to provide voltage support to the AC grid. The proposed control scheme provides faster fault current suppression, more effective SM capacitor voltage regulation, low AC side and MMC arm current transient peaks, and an overall superior DC-FRT performance compared to methods in which the conventional fault ride-through operation is initiated immediately upon DC fault detection.
引用
收藏
页数:23
相关论文
共 50 条
  • [11] DC Short Circuit Ride-through Strategy for a Full-Bridge MMC HVDC Transmission System
    Fawzi, M.
    Briz, Fernando
    Kalas, A. E.
    [J]. 2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [12] DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System
    ChengYong Zhao
    JianZhong Xu
    Tan Li
    [J]. Science China Technological Sciences, 2013, 56 : 253 - 261
  • [13] DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System
    Zhao ChengYong
    Xu JianZhong
    Li Tan
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (01) : 253 - 261
  • [14] DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System
    ZHAO ChengYong
    XU JianZhong
    LI Tan
    [J]. Science China Technological Sciences, 2013, (01) : 253 - 261
  • [15] Simulation Test of a DC Fault Current Limiter for Fault Ride-Through Problem of Low-Voltage DC Distribution
    Han, Bing
    Li, Yonggang
    [J]. ENERGIES, 2020, 13 (07)
  • [16] Controllable DC-link fault current limiter augmentation with DC chopper to improve fault ride-through of DFIG
    Jalilian, Amin
    Naderi, Seyed Behzad
    Negnevitsky, Michael
    Hagh, Mehrdad Tarafdar
    Muttaqi, Kashem M.
    [J]. IET RENEWABLE POWER GENERATION, 2017, 11 (02) : 312 - 323
  • [17] Increase of Fault Ride-Through Capability of Wind Farms by Using Bridge-Type Fault Current Limiter
    Ahmadi, H.
    Sheisi, G. H.
    Firouzi, M.
    [J]. 2012 INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES 2012), 2012, 13 : 48 - 55
  • [18] Principle, Control and Comparison of Modular Multilevel Converters (MMCs) with DC Short Circuit Fault Ride-through Capability
    Cui, Shenghui
    Kim, Sungmin
    Jung, Jae-Jung
    Sul, Seung-Ki
    [J]. 2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 610 - +
  • [19] An Energy Absorbing Method for Hybrid MMCs to Avoid Full-Bridge Submodule Overvoltage During DC Fault Blocking
    Fang, Xiongfeng
    Li, Gen
    Chen, Canfeng
    Wang, Dongyu
    Xiong, Jian
    Zhang, Kai
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (05) : 4947 - 4951
  • [20] DC Fault Ride-Through of a Three-Phase Dual-Active Bridge Converter for DC Grids
    Hu, Jingxin
    Cui, Shenghui
    De Doncker, Rik W.
    [J]. 2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 2250 - 2256