Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

被引:53
|
作者
Zeidan, O. A. [1 ]
Sriprisan, S. I. [1 ]
Lopatiuk-Tirpak, O. [1 ]
Kupelian, P. A. [1 ]
Meeks, S. L. [1 ]
Hsi, W. C. [2 ]
Li, Z. [2 ]
Palta, J. R. [2 ]
Maryanski, M. J. [3 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Orlando, FL 32806 USA
[2] Univ Florida, Proton Therapy Inst, Jacksonville, FL 32206 USA
[3] MGS Res Inc, Madison, CT 06443 USA
关键词
dosimeters; polymer gels; radiation therapy; RADIATION-DOSE DISTRIBUTIONS; BEAM; VERIFICATION; PERFORMANCE; SCANNER;
D O I
10.1118/1.3388869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.
引用
收藏
页码:2145 / 2152
页数:8
相关论文
共 50 条
  • [41] Dosimetric investigations on radiation-induced Ag nanoparticles in a gel dosimeter
    Tadros, Soad M.
    Soliman, Yasser S.
    Beshir, W. B.
    Saad, Gamal R.
    Ali, Laila, I
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 329 (01) : 463 - 473
  • [42] Dosimetric evaluation of a new design MOSFET in vivo dosimeter
    Halvorsen, PH
    MEDICAL PHYSICS, 2005, 32 (01) : 110 - 117
  • [43] EVALUATION OF DOSIMETRIC CHARACTERISTICS OF A GLASS RPL PERSONAL DOSIMETER
    Pooya, S. M. Hosseini
    Arezabak, B.
    Alebrahim, H.
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 139 - 141
  • [44] End-to-End QA with Polymer Gel Dosimeter for Photon Beam Radiation Therapy
    Zhu, Libing
    Du, Yi
    Peng, Yahui
    Xiang, Xincheng
    Wang, Xiangang
    GELS, 2023, 9 (03)
  • [45] Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields
    Parwaie, W.
    Yarahmadi, M.
    Nedaie, H. A.
    Zahmatkesh, M. H.
    Barati, A. H.
    Afkhami, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (01): : 59 - 65
  • [46] Dose response evaluation of a low density anoxic polymer gel dosimeter using MRI
    Gholami, M.
    Shahbazi-Gahrouei, D.
    Pourfallah, T. Allahverdi
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (03): : 243 - 249
  • [47] Application of polymer-gel dosimeter for evaluation of relative dose distributions in stereotactic radiotherapy
    Novotny, JJ
    Spevacek, V
    Dvorak, P
    Novotny, J
    Hrbacek, J
    Tintera, J
    Vymazal, J
    Cechak, T
    Michalek, J
    Vacik, J
    Liscak, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S51 - S51
  • [48] Determination of the Water Equivalent Thickness of Strata XRT Gel and Evaluation of the Dosimetric Effect of Its Application On the Skin of Proton Therapy Patients
    Gautam, A.
    McGovern, S.
    Zhu, X.
    Sahoo, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E542 - E542
  • [49] IMAGING OF ABSORBED DOSE IN RADIOTHERAPY BY A POLYMER GEL DOSIMETER
    Vanossi, E.
    Gambarini, G.
    Carrara, M.
    Mariani, M.
    Negri, A.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 689 - +
  • [50] Development of a novd normoxic polymer gel dosimeter (TENOMAG)
    Cho, Sam Ju
    Shin, Dongho
    Do Huh, Hyun
    Lee, Sang Hoon
    Lim, Sang Wook
    Jang, Jisun
    Cho, Kwang Hwan
    Shin, Hun Joo
    Kwon, Sooil
    Yun, Hyong Geun
    Yun, Sang Mo
    Shin, Dong Oh
    Yang, Dae Sik
    Park, Young Je
    Kim, Chul Yong
    Lee, Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (05) : 1798 - 1804