Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

被引:53
|
作者
Zeidan, O. A. [1 ]
Sriprisan, S. I. [1 ]
Lopatiuk-Tirpak, O. [1 ]
Kupelian, P. A. [1 ]
Meeks, S. L. [1 ]
Hsi, W. C. [2 ]
Li, Z. [2 ]
Palta, J. R. [2 ]
Maryanski, M. J. [3 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Orlando, FL 32806 USA
[2] Univ Florida, Proton Therapy Inst, Jacksonville, FL 32206 USA
[3] MGS Res Inc, Madison, CT 06443 USA
关键词
dosimeters; polymer gels; radiation therapy; RADIATION-DOSE DISTRIBUTIONS; BEAM; VERIFICATION; PERFORMANCE; SCANNER;
D O I
10.1118/1.3388869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.
引用
收藏
页码:2145 / 2152
页数:8
相关论文
共 50 条
  • [21] Dosimetric Characteristics of a Glass Dosimeter for Proton Beam Measurements
    Rah, J.
    Kim, D.
    Park, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3510 - +
  • [22] Dosimetric assessment of the PRESAGE dosimeter for a proton pencil beam
    Wuu, C-S
    Xu, Y.
    Qian, X.
    Adamovics, J.
    Cascio, E.
    Lu, H-M
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [23] Dosimetric Evaluation of Heterogeneity Correction Algorithm for Proton Therapy
    Rah, J.
    Suh, T.
    Park, S.
    Jeong, H.
    Hwang, U.
    Lee, S.
    Yoon, M.
    Shin, D.
    Park, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [24] Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code
    Park, M.
    Kim, G.
    Ji, Y.
    Kim, K.
    Park, S.
    Jung, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3510 - 3510
  • [25] Dose evaluation of an NIPAM polymer gel dosimeter using gamma index
    Chang, Yuan-Jen
    Lin, Jing-Quan
    Hsieh, Bor-Tsung
    Yao, Chun-Hsu
    Chen, Chin-Hsing
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 180 - 187
  • [26] Dosimetric properties of PASSAG polymer gel dosimeter in electron beam radiotherapy using magnetic resonance imaging
    Zhang, Tiancheng
    Almajidi, Yasir Q.
    Awad, Sameer A.
    Alhachami, Firas Rahi
    Gatea, Maher Abdulfadhil
    Kadhum, Wesam R.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (04) : 825 - 836
  • [27] Evaluation of a novel N-(Hydroxymethyl) acrylamide polymer gel dosimeter formulation with organic glucose additive for radiotherapy
    Eyadeh, Molham M.
    Rabaeh, Khalid A.
    Issa, Abdallah S. B.
    Diamond, Kevin R.
    RADIATION MEASUREMENTS, 2023, 166
  • [28] Evaluation of a Novel 3-D Polymer Gel Dosimetry System for Proton Radiotherapy
    Lopatiuk-Tirpak, O.
    Langen, K.
    Meeks, S.
    Kupelian, P.
    Maryanski, M.
    Hsi, W.
    Palta, J.
    Zeidan, O.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] MAGIC polymer gel for dosimetric verification in boron neutron capture therapy
    Uusi-Simola, Jouni
    Heikkinen, Sami
    Kotiluoto, Petri
    Seren, Tom
    Seppala, Tiina
    Auterinen, Iiro
    Savolainen, Sauli
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 114 - 123
  • [30] Verification of X-Ray Proton Hybrid Patch Irradiation Using Polymer Gel Dosimeter
    Ishida, M.
    Kawamura, H.
    Mori, Y.
    Tomita, T.
    Sakae, T.
    MEDICAL PHYSICS, 2024, 51 (10) : 7915 - 7916