Use of flow cytometry and SNARF to calibrate and measure intracellular pH in NSO cells

被引:25
|
作者
Bond, J [1 ]
Varley, J [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
关键词
calibration; flow cytometry; intracellular pH; NSO; 1,5-(and-6)-carboxy seminaphtorhodafluor-1-acetoxymethyl ester;
D O I
10.1002/cyto.a.20066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Two calibration methods have been proposed for determining the relation between the fluorescence ratio of a pH-sensitive fluorescent indicator and intracellular pH (pH(i)). The first method uses nigericin to clamp pH(i) to external pH (pH(e)) and the second is the null point method. We compared these different calibration methods, solution conditions, and temperatures by using flow cytometry and the fluorescent dye 1,5- (and-6)-carboxy seminaphtorhodafluor-1-acetoxymethyl ester with an NS0 cell line. Methods: The nigericin method was performed in glucose solutions supplemented with KCl and 2-(N-morpholino)ethane sulphonic acid plus tris(hydroxymethyl)aminomethane (solution 1A), a mixture of K2HPO4/KH2PO4 in glucose-solution supplemented solutions (solution 2A), or bicarbonate buffered growth medium supplemented with K2HPO4/KH2PO4 (solution 2B); this allowed a range of pH, values to be used. The effect of temperature (22degreesC or 37degreesC) on the nigericin calibration curve was also investigated. The null point method was performed by using a series of solutions with a mixture of weak acid and base with a known pHi response. Results: Using solution 1A as the calibration solution resulted in acidic values of pH(i) for cells cultured in medium as compared with the values achieved with solution 2A. Using solution 213 did not affect the calibration curve. For the temperatures considered in this study, there was no affect on the calibration curve, but temperature did affect the pHi value of cells in phosphate buffered saline. The pseudo-null point method used with flow cytometry resulted in a calibration curve that was significantly different (P < 0.05) from that achieved using the nigericin method. Conclusions: Our data indicates that the choice of calibration solution can affect the reported pHi value; therefore, careful choice of solution is important. (C) 2005 Wiley-Liss, Inc.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 50 条
  • [41] Investigating the uptake and intracellular fate of pH-sensitive liposomes by flow cytometry and spectral bio-imaging
    Huth, US
    Schubert, R
    Peschka-Süss, R
    JOURNAL OF CONTROLLED RELEASE, 2006, 110 (03) : 490 - 504
  • [42] INTRACELLULAR PH MEASUREMENTS USING FLOW-CYTOMETRY WITH 1,4-DIACETOXY-2,3-DICYANOBENZENE
    COOK, JA
    FOX, MH
    CYTOMETRY, 1988, 9 (05): : 441 - 447
  • [43] Simultaneous Measurement of Changes in Neutrophil Granulocyte Membrane Potential, Intracellular pH, and Cell Size by Multiparametric Flow Cytometry
    Stratmann, Alexander Elias Paul
    Wohlgemuth, Lisa
    Erber, Maike Elisabeth
    Bernhard, Stefan
    Hug, Stefan
    Fauler, Michael
    Vidoni, Laura
    Mohamed, Adam Omar Khalaf
    Thomass, Bertram Dietrich
    Munnich, Frederik
    Stukan, Laura
    Fohr, Karl Josef
    Mannes, Marco
    Huber-Lang, Markus Stefan
    Messerer, David Alexander Christian
    BIOMEDICINES, 2021, 9 (11)
  • [44] Live Cell Measurement of the Intracellular pH of Yeast by Flow Cytometry Using a Genetically-Encoded Fluorescent Reporter
    Triandafillou, Catherine G.
    Drummond, D. Allan
    BIO-PROTOCOL, 2020, 10 (12):
  • [45] Quantification of plasmid loss in Escherichia coli cells by use of flow cytometry
    Bahl, ML
    Sorensen, SJ
    Hansen, LH
    FEMS MICROBIOLOGY LETTERS, 2004, 232 (01) : 45 - 49
  • [46] Use of flow cytometry techniques in studying mechanisms of apoptosis in leukemic cells
    Gorman, AM
    Samali, A
    McGowan, AJ
    Cotter, TG
    CYTOMETRY, 1997, 29 (02): : 97 - 105
  • [47] USE OF TETRAMERIC ANTIBODY COMPLEXES TO STAIN CELLS FOR FLOW-CYTOMETRY
    WOGNUM, AW
    THOMAS, TE
    LANSDORP, PM
    CYTOMETRY, 1987, 8 (04): : 366 - 371
  • [48] Use of quantitative flow cytometry to measure ex vivo immunostimulant activity of Echinacea:: The case for polysaccharides
    Pillai, Segaran
    Pillai, Christine
    Mitscher, Lester A.
    Cooper, Raymond
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2007, 13 (06) : 625 - 634
  • [49] Detection of intracellular cytokine production by cord blood T cells using flow cytometry.
    Racadot, E
    Gay, C
    Billot, M
    Herve, P
    BLOOD, 1997, 90 (10) : 2970 - 2970
  • [50] Assessment by flow cytometry of intracellular cytokine production in the peripheral blood cells of renal transplant recipients
    Magee, CC
    Denton, MD
    Womer, KL
    Khoury, SJ
    Sayegh, MH