Use of flow cytometry and SNARF to calibrate and measure intracellular pH in NSO cells

被引:25
|
作者
Bond, J [1 ]
Varley, J [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn & Chem Technol, London SW7 2AZ, England
关键词
calibration; flow cytometry; intracellular pH; NSO; 1,5-(and-6)-carboxy seminaphtorhodafluor-1-acetoxymethyl ester;
D O I
10.1002/cyto.a.20066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Two calibration methods have been proposed for determining the relation between the fluorescence ratio of a pH-sensitive fluorescent indicator and intracellular pH (pH(i)). The first method uses nigericin to clamp pH(i) to external pH (pH(e)) and the second is the null point method. We compared these different calibration methods, solution conditions, and temperatures by using flow cytometry and the fluorescent dye 1,5- (and-6)-carboxy seminaphtorhodafluor-1-acetoxymethyl ester with an NS0 cell line. Methods: The nigericin method was performed in glucose solutions supplemented with KCl and 2-(N-morpholino)ethane sulphonic acid plus tris(hydroxymethyl)aminomethane (solution 1A), a mixture of K2HPO4/KH2PO4 in glucose-solution supplemented solutions (solution 2A), or bicarbonate buffered growth medium supplemented with K2HPO4/KH2PO4 (solution 2B); this allowed a range of pH, values to be used. The effect of temperature (22degreesC or 37degreesC) on the nigericin calibration curve was also investigated. The null point method was performed by using a series of solutions with a mixture of weak acid and base with a known pHi response. Results: Using solution 1A as the calibration solution resulted in acidic values of pH(i) for cells cultured in medium as compared with the values achieved with solution 2A. Using solution 213 did not affect the calibration curve. For the temperatures considered in this study, there was no affect on the calibration curve, but temperature did affect the pHi value of cells in phosphate buffered saline. The pseudo-null point method used with flow cytometry resulted in a calibration curve that was significantly different (P < 0.05) from that achieved using the nigericin method. Conclusions: Our data indicates that the choice of calibration solution can affect the reported pHi value; therefore, careful choice of solution is important. (C) 2005 Wiley-Liss, Inc.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 50 条
  • [21] INTRACELLULAR PH MAPPING WITH SNARF-1 AND CONFOCAL MICROSCOPY .1. A QUANTITATIVE TECHNIQUE FOR LIVING TISSUES AND ISOLATED CELLS
    CODY, SH
    DUBBIN, PN
    BEISCHER, AD
    DUNCAN, ND
    HILL, JS
    KAYE, AH
    WILLIAMS, DA
    MICRON, 1993, 24 (06) : 573 - 580
  • [22] THE USE OF DUAL-COLOR FLOW-CYTOMETRY FOR THE DETECTION OF INTRACELLULAR CYTOKINES
    SINCLAIR, DA
    BRAY, RA
    FASEB JOURNAL, 1995, 9 (03): : A536 - A536
  • [23] USE OF FLOW-CYTOMETRY FOR RAPID ESTIMATION OF INTRACELLULAR EVENTS IN BREWING YEASTS
    JESPERSEN, L
    JAKOBSEN, M
    JOURNAL OF THE INSTITUTE OF BREWING, 1994, 100 (06) : 399 - 403
  • [24] Use of flow cytometry and monochlorobimane to quantitate intracellular glutathione concentrations in feline leukocytes
    Webb, Craig
    Bedwell, Cathy
    Guth, Amanda
    Avery, Paul
    Dow, Steven
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2006, 112 (3-4) : 129 - 140
  • [25] PHAGOCYTOSIS, INTRACELLULAR PH, AND CELL-VOLUME IN THE MULTIFUNCTIONAL ANALYSIS OF GRANULOCYTES BY FLOW-CYTOMETRY
    ROTHE, G
    VALET, G
    CYTOMETRY, 1988, 9 (04): : 316 - 324
  • [26] USE OF FLUORESCENT DYE BCECF TO MEASURE INTRACELLULAR PH IN CORTICAL COLLECTING TUBULE
    WEINER, ID
    HAMM, LL
    AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (05): : F957 - F964
  • [27] The use of FDA and flow cytometry to measure the metabolic activity of the cyanobacteria, Microcystis aeruginosa
    Geary, S
    Ganf, G
    Brookes, J
    INTERNATIONAL ASSOCIATION OF THEORETICAL AND APPLIED LIMNOLOGY, PROCEEDINGS - VOL 26, PT 5, 1998, 26 : 2367 - 2369
  • [28] FLOW-CYTOMETRY STUDIES OF INTRACELLULAR ADRIAMYCIN IN SINGLE CELLS-INVITRO
    DURAND, RE
    OLIVE, PL
    CANCER RESEARCH, 1981, 41 (09) : 3489 - 3494
  • [29] The use of flow cytometry and fluorescein-labeled antibodies to measure specific milk proteins in bovine mammary epithelial cells
    Keys J.E.
    Guidry A.J.
    Cifrian E.
    In Vitro Cellular & Developmental Biology - Animal, 1997, 33 (3) : 201 - 205
  • [30] The Use of DRAQ5 to Monitor Intracellular DNA in Escherichia coli by Flow Cytometry
    Silva, Filomena
    Lourenco, Olga
    Pina-Vaz, Cidalia
    Rodrigues, Acacio G.
    Queiroz, Joao A.
    Domingues, Fernanda Conceicao
    JOURNAL OF FLUORESCENCE, 2010, 20 (04) : 907 - 914