Arc-fault protection of branch circuits, cords and connected equipment

被引:0
|
作者
Parise, G [1 ]
Martirano, L [1 ]
Nabours, RE [1 ]
机构
[1] Univ Roma La Sapienza, Dept Elect Engn, I-00184 Rome, Italy
关键词
circuit protection; arcing fault;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In electrical power systems, the fault frequently involves arcing and burning for all the wiring exposed to mechanical damage and other insulation stresses including wiring not fixed and connected by flexible cords and cables. The EEC Standard 60364 stops the design of electric power systems at the outlets of branch circuits or at the fixed equipment. A complete design instead should take care of the connections of the portable equipment and of extension cords (as requested by NFPA 70) that are exposed to are faults and may cause fire and/or electric shock hazard. The cords supplying the Class II equipment are without a grounding protection conductor, so the failure of the double insulation, caused by external damage, can't be expected to be easily detected as a ground fault. A protection must be provided to prevent the fault from extinguishing itself without being detected and remaining energized, thus presenting an electric shock hazard by direct contact with a live part, rendered accessible after local insulation failure. The authors highlight this worst case and suggest the protection achieved by wiring the circuits, particularly extension cords, with special power cables. Ground-Fault-Forced Cables, GFFCs convert a line-to-line fault into a line to ground fault, that will be detected and protected by ordinary ground fault protective devices (GFPDs). By adopting the GFFC type of cables internally to Class II equipment, the disconnecting supplying measure could be extended to equipment also.
引用
收藏
页码:85 / 88
页数:4
相关论文
共 50 条
  • [1] Arc-fault protection of branch circuits, cords, and connected equipment
    Parise, G
    Martirano, L
    Nabours, RE
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (03) : 896 - 899
  • [2] Localized Fire Ignition Hazard In Branch Circuits, Cords And Connected Equipment
    Parise, Giuseppe
    Parise, Luigi
    Nicolucci, Paolo
    [J]. 2011 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2011,
  • [3] The arc-fault circuit protection
    Parise, G
    Martirano, L
    Grasselli, U
    Benetti, L
    [J]. CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 1817 - 1822
  • [4] Enhancing Worker and Equipment Protection Through Passive Arc-Fault Mitigation
    Parsons, Antony
    Faber, Timothy
    Metzdorf, Mark A.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (03) : 2196 - 2204
  • [5] History of Aircraft Wiring Arc-Fault Protection
    Brusso, Barry C.
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2017, 23 (03) : 6 - 11
  • [6] DC arc-fault hazards analysis and protection in photovoltaic system
    Wu, Chunhua
    Xu, Wenxin
    Li, Zhihua
    Wang, Fei
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (09): : 198 - 206
  • [7] Prevention of electrical failure in photovoltaic array-II (ground-fault protection and arc-fault protection)
    [J]. Ishii, Takafumi, 1600, Institute of Electrical Engineers of Japan (134):
  • [8] ARC FAULT PROTECTION AGAINST SHORT CIRCUITS
    不详
    [J]. CONTROL AND INSTRUMENTATION, 1979, 11 (07): : 15 - 15
  • [9] More about arc-fault circuit interrupters
    Gregory, GD
    Wong, K
    Dvorak, RF