History of Aircraft Wiring Arc-Fault Protection

被引:18
|
作者
Brusso, Barry C.
机构
关键词
D O I
10.1109/MIAS.2017.2659022
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In both new and aging military and civilian aircraft, all critical power wiring has been typically protected against overheating by using combinations of thermal and magnetic circuit breakers or solid-state power controllers (SSPCs). However, the conventional types of these protective devices do not detect and react to hazardous arcing faults, and it is important that they do so to mitigate the risk of aircraft fires caused by aging, damaged insulation, wire chafing, wire breakage, chemical exposure, maintenance procedures, and contamination. Most aircraft electrical systems operate at 115 Vac, 400 Hz, both single and three phase. In addition to this ac power, they utilize 28 Vdc. Hazardous arcing faults can occur in all these power systems between parallel conductors, to ground, or in series (due to a broken or frayed wire or at a loose connection). © 2017 IEEE.
引用
收藏
页码:6 / 11
页数:6
相关论文
共 50 条
  • [1] The arc-fault circuit protection
    Parise, G
    Martirano, L
    Grasselli, U
    Benetti, L
    [J]. CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 1817 - 1822
  • [2] Arc-fault protection of branch circuits, cords, and connected equipment
    Parise, G
    Martirano, L
    Nabours, RE
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (03) : 896 - 899
  • [3] Arc fault signatures detection on aircraft wiring system
    Zhang, Hongkun
    Chen, Tao
    Li, Wenjun
    [J]. WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 5548 - +
  • [4] Arc-fault protection of branch circuits, cords and connected equipment
    Parise, G
    Martirano, L
    Nabours, RE
    [J]. 2003 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2003, : 85 - 88
  • [5] ARC-FAULT DETECTION BY FREQUENCY ANALYSIS OF CURRENT IN A CONTINUOUS AIRCRAFT POWER NETWORKS
    Humbert, Jean-Baptiste
    Schweitzer, Patrick
    Weber, Serge
    [J]. 28TH INTERNATIONAL CONFERENCE ON ELECTRIC CONTACTS (ICEC2016), 2016, : 207 - 211
  • [6] Enhancing Worker and Equipment Protection Through Passive Arc-Fault Mitigation
    Parsons, Antony
    Faber, Timothy
    Metzdorf, Mark A.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (03) : 2196 - 2204
  • [7] A Survey on Arc Fault Detection and Wire Fault Location for Aircraft Wiring Systems
    Liu, Guangjun
    Cao, Yin Ni
    Liu, Yugang
    Liu, Zhenning
    [J]. SAE INTERNATIONAL JOURNAL OF AEROSPACE, 2009, 1 (01): : 903 - 914
  • [8] More about arc-fault circuit interrupters
    Gregory, GD
    Wong, K
    Dvorak, RF
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (04) : 1006 - 1011
  • [9] A Micro-fabricated current sensor for arc fault detection of aircraft wiring
    Moffat, Brian G.
    Desmulliez, Marc P. Y.
    Brown, Keith
    Desai, Chintan
    Flynn, David
    Sutherland, Alistair
    [J]. ESTC 2008: 2ND ELECTRONICS SYSTEM-INTEGRATION TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2008, : 299 - +
  • [10] Simplified Arc-Fault Model: the Reduction Factor of the Arc Current
    Parise, Giuseppe
    Martirano, Luigi
    Laurini, Marco
    [J]. 2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,