Coherent diffraction radiation interferometry and short bunch length measurements

被引:1
|
作者
Potylitsyn, AP [1 ]
机构
[1] Tomsk Polytech Univ, Tomsk 634050, Russia
关键词
diffraction radiation; electron beam diagnostics;
D O I
10.1016/j.nimb.2004.06.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The promising approach to measure a length of subpicosecond electron bunch is connected with measurements of coherent diffraction radiation (CDR) spectra due to strong dependence of the spectrum shape on the bunch length sigma(z) in the wavelength region lambda similar to sigma(z) [Proceedings of the International Symposium on New Visions in Laser-Beam Interactions, Nucl. Instr. and Meth. A 455 (1) (2000)]. The spectral measurements may be carried out by using an interferometer or a polychromator. The alternative approach for similar measurements is proposed in the paper. The interference pattern from two shifted halves of a CDR target may be used for this aim. If the broadband detector measures a CDR yield around lambda(0) similar to sigma(z) then moving one half of the CDR target relative to other (parallel to beam) in the range of a few bunch lengths one can obtain the detuning curve (interferogram). The shape of detuning curve and its connection with bunch length is calculated for different detector apertures and detector waveband. The proposed technique may open the new possibility for non-invasive bunch length measurements in the subpicosecond range. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [31] Measurement of < 20 fs bunch length using coherent transition radiation
    Nozawa, I.
    Kan, K.
    Yang, J.
    Ogata, A.
    Kondoh, T.
    Gohdo, M.
    Norizawa, K.
    Kobayashi, H.
    Shibata, H.
    Gonda, S.
    Yoshida, Y.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2014, 17 (07):
  • [32] Coherent Smith-Purcell radiation as a diagnostic for subpicosecond electron bunch length
    Nguyen, DC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 393 (1-3): : 514 - 518
  • [33] Vector diffraction theory and coherent transition radiation interferometry in electron linacs
    Maxwell, T. J.
    Bohn, C. L.
    Mihalcea, D.
    Piot, P.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 418 - +
  • [34] Relative bunch length monitor for the linac coherent light source (LCLS) using coherent edge radiation
    Loos, H.
    Borden, T.
    Emma, P.
    Frisch, J.
    Wu, J.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 508 - 510
  • [35] Overview of bunch length measurements
    Lumpkin, AH
    FREE-ELECTRON LASER CHALLENGES II, 1999, 3614 : 44 - 52
  • [36] Bunch length measurements on CLIO
    Glotin, F.
    Berset, J.-M.
    Chaput, R.
    Jaroszynski, D.A.
    Ortega, J.-M.
    Prazeres, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A341 (1-3) : 49 - 53
  • [37] BUNCH LENGTH MEASUREMENTS ON CLIO
    GLOTIN, F
    BERSET, JM
    CHAPUT, R
    JAROSZYNSKI, DA
    ORTEGA, JM
    PRAZERES, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 341 (1-3): : 49 - 53
  • [38] Bunch length measurements at BESSY
    Abo-Bakr, M
    Anders, W
    Kuske, P
    Wüstefeld, G
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3020 - 3022
  • [39] Bunch heating by coherent synchrotron radiation
    Heifets, SA
    Zolotorev, M
    MICRO BUNCHES WORKSHOP, 1996, (367): : 256 - 262
  • [40] Coherent synchrotron radiation detector for a non-invasive subpicosecond bunch length monitor
    Krafft, GA
    Wang, D
    Price, E
    Feldl, E
    Porterfield, D
    Wood, P
    Crowe, T
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2601 - 2603