Coherent diffraction radiation interferometry and short bunch length measurements

被引:1
|
作者
Potylitsyn, AP [1 ]
机构
[1] Tomsk Polytech Univ, Tomsk 634050, Russia
关键词
diffraction radiation; electron beam diagnostics;
D O I
10.1016/j.nimb.2004.06.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The promising approach to measure a length of subpicosecond electron bunch is connected with measurements of coherent diffraction radiation (CDR) spectra due to strong dependence of the spectrum shape on the bunch length sigma(z) in the wavelength region lambda similar to sigma(z) [Proceedings of the International Symposium on New Visions in Laser-Beam Interactions, Nucl. Instr. and Meth. A 455 (1) (2000)]. The spectral measurements may be carried out by using an interferometer or a polychromator. The alternative approach for similar measurements is proposed in the paper. The interference pattern from two shifted halves of a CDR target may be used for this aim. If the broadband detector measures a CDR yield around lambda(0) similar to sigma(z) then moving one half of the CDR target relative to other (parallel to beam) in the range of a few bunch lengths one can obtain the detuning curve (interferogram). The shape of detuning curve and its connection with bunch length is calculated for different detector apertures and detector waveband. The proposed technique may open the new possibility for non-invasive bunch length measurements in the subpicosecond range. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [11] Bunch length measurements at the JLab FEL using coherent transition and synchrotron radiation
    Evtushenko, P.
    Coleman, J.
    Jordan, K.
    Klopf, J. Michael
    Neil, G.
    Williams, G. P.
    BEAM INSTRUMENTATION WORKSHOP 2006, 2006, 868 : 193 - +
  • [12] A fast coherent synchrotron radiation monitor for the bunch length of the short CEBAF bunches
    Wang, DX
    Krafft, GA
    Price, E
    Wood, P
    Porterfield, D
    Crowe, T
    MICRO BUNCHES WORKSHOP, 1996, (367): : 502 - 511
  • [13] Coherent diffraction radiation from an electron bunch
    Mkrtchyan, AR
    Gevorgian, LA
    Grigorian, LS
    Khachatryan, BV
    Saharian, AA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 145 (1-2): : 67 - 72
  • [14] Coherent diffraction radiation from an electron bunch
    Mkrtchyan, A.R.
    Gevorgian, L.A.
    Grigorian, L.Sh.
    Khachatryan, B.V.
    Saharian, A.A.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1998, 145 (1-2): : 67 - 72
  • [15] Design and experimental verification of a bunch length monitor based on coherent Cherenkov diffraction radiation
    Davut, C.
    Xia, G.
    Apsimon, O.
    Mcgunigal, J.
    Karataev, P.
    Lefevre, T.
    Mazzoni, S.
    Senes, E.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2025, 28 (02)
  • [16] Experimental characterization of sub-picosecond electron bunch length with coherent diffraction radiation
    Xiang Dao
    Yang Xing-Fan
    Huang Wen-Hui
    Tang Chuan-Xiang
    Lin Yu-Zheng
    Li Wei-Hua
    Pan Qing
    Li Ming
    CHINESE PHYSICS LETTERS, 2008, 25 (07) : 2440 - 2443
  • [17] Thomson scattering of coherent diffraction radiation by an electron bunch
    Potylitsyn, AP
    PHYSICAL REVIEW E, 1999, 60 (02): : 2272 - 2279
  • [18] Diffraction effects in length measurements by laser interferometry
    Sasso, C. P.
    Massa, E.
    Mana, G.
    OPTICS EXPRESS, 2016, 24 (06): : 6522 - 6531
  • [19] Electron bunch shape measurement using coherent diffraction radiation
    Feng, B
    Oyamada, M
    Hinode, F
    Sato, S
    Kondo, Y
    Shibata, Y
    Ikezawa, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3): : 492 - 497