MR imaging-guided biliary drainage in an open low-field system: First clinical experiences

被引:13
|
作者
Wacker, FK
Faiss, S
Reither, K
Zimmer, T
Wendt, M
Wolf, KJ
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Radiol, D-12200 Berlin, Germany
[2] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Internal Med Gastroenterol, D-12200 Berlin, Germany
[3] Case Western Reserve Univ, Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[4] Siemens Med Syst Inc, Iselin, NJ 08830 USA
关键词
MR imaging-guided procedures; interventional MRI; MR cholangiography; biliary drainage; susceptibility artifacts;
D O I
10.1055/s-2000-7223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the feasibility of MR imaging (MRI)-guided percutaneous biliary drainages in patients using an open MR-system. Methods: 6 patients with mechanical cholestasis underwent MRI-guided puncture and catheterization of the biliary system following intervention planning with magnetic resonance cholangiography (MRC) in an open low-field MR system. Data on the number of punctures required, success in establishing external and internal drainage, and total procedure time were compared to those of 6 patients who underwent biliary drainage with fluoroscopic guidance. Results: MRC facilitated intervention planning in all patients. Near-real-time MR imaging enabled interactive positioning of the devices. The bile ducts were punctured under MRI control in three patients in the first, in two in the second, and in one in the third attempt. MRI-guided puncture was faster than the fluoroscopic procedure. Catheterization for external drainage was successful in all patients. Passing the obstructions was not possible under MRI guidance. The procedure time for MRI-guided catheterization was longer than in the conventional technique. Conclusion: MRI-guidance allows reliable placement of an external biliary drainage in an open low-field MR system.
引用
收藏
页码:744 / 747
页数:4
相关论文
共 50 条
  • [41] Setting up MR compatibility of a commercial stereo-localization system for low-field open MR interventional procedures
    Viard, Romain
    Vermandel, Maximilien
    Rousseau, Jean
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (01) : 65 - 69
  • [42] Dynamic MR defecography with an open-configuration, low-field, tilting MR system in patients with pelvic floor disorders
    Fiaschetti, V.
    Squillaci, E.
    Pastorelli, D.
    Rascioni, M.
    Funel, V.
    Salimbeni, C.
    Fanucci, E.
    Simonetti, G.
    RADIOLOGIA MEDICA, 2011, 116 (04): : 620 - 633
  • [43] INTRAOPERATIVE NEUROPHYSIOLOGICAL MONITORING IN AN OPEN LOW-FIELD MAGNETIC RESONANCE IMAGING SYSTEM: CLINICAL EXPERIENCE AND TECHNICAL CONSIDERATIONS COMMENTS
    Friedman, William A.
    Schulder, Michael
    Hall, Walter A.
    Gutin, Philip H.
    NEUROSURGERY, 2008, 63 (04) : 275 - 276
  • [44] Intraoperative low-field MR imaging in neurosurgery - experience in 300 patients
    Nimsky, C
    Ganslandt, O
    Gralla, J
    Tomandl, B
    Kober, H
    Hastreiter, P
    Buchfelder, M
    Fahlbusch, R
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 231 - 235
  • [45] Optimizing brain tumor resection - Low-field interventional MR imaging
    Metzger, AK
    Lewin, JS
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2001, 11 (04) : 651 - +
  • [46] 4First two years clinical experience with low-field MR-IGRT-system practicality and future implications
    Michalski, J. M.
    Green, O. L.
    Kashani, R.
    Li, H.
    Rodriguez, V.
    Zhao, T.
    Yang, D.
    Bradley, J. D.
    Zoberi, I.
    Thomas, M. A.
    Robinson, C.
    Parikh, P.
    Olsen, J.
    Mutic, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S231 - S232
  • [47] Low-field MR imaging for the assessment of therapy response in musculoskeletal infections
    Hovi, I.
    Valtonen, M.
    Korhola, O.
    Hekali, P.
    Acta Radiologica, 1995, 36 (03): : 220 - 227
  • [48] Technical Feasibility of Transperineal MR-Guided Prostate Interventions in a Low-Field Open MRI Unit: Canine Study
    Ferenc Lakosi
    Antal, Gergely
    Csaba Vandulek
    Arpad Kovacs
    Garamvolgyi, Rita
    Ors Petnehazy
    Bajzik, Gabor
    Hadjiev, Janaki
    Imre Repa
    Bogner, Peter
    PATHOLOGY & ONCOLOGY RESEARCH, 2009, 15 (03) : 315 - 322
  • [49] Contrast-enhanced breast MR imaging of claustrophobic or oversized patients using an open low-field magnet
    Calabrese, M.
    Brizzi, D.
    Carbonaro, L.
    Chiaramondia, M.
    Kirchin, M. A.
    Sardanelli, F.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 267 - 285
  • [50] Diffusion weighted MR imaging on a low-field open magnet in stroke - Evaluation in a consecutive series of 60 patients
    Somon, T
    Kelekis, A
    Wetzel, S
    Mehdizade, A
    Martin, JB
    Stajzel, R
    Lovblad, KO
    Ruefenacht, DA
    Delavelle, J
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (05): : 1005 - 1008