Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility

被引:14
|
作者
Grinstein, Jonathan [1 ]
Torii, Ryo [2 ]
Bourantas, Christos V. [3 ]
Garcia-Garcia, Hector M. [4 ]
机构
[1] Univ Chicago, Dept Med, Cardiol Sect, Chicago, IL 60637 USA
[2] UCL, Dept Mech Engn, London, England
[3] Barts Heart Ctr, Dept Cardiol, London, England
[4] MedStar Cardiovasc Res Network, Washington, DC USA
关键词
computational fluid dynamics; LVAD flow; Programable flow algorithms; shear stress; shear rate; COMPUTATIONAL FLUID-DYNAMICS; HEARTMATE II; BLOOD-FLOW; SUPPORT; THROMBOSIS; STRESS; SYSTEM;
D O I
10.1097/MAT.0000000000001341
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our current understanding of flow through the circuit of left ventricular assist device (LVAD), left ventricle and ascending aorta remains incompletely understood. Computational fluid dynamics, which allow for analysis of flow in the cardiovascular system, have been used for this purpose, although current simulation models have failed to fully incorporate the interplay between the pulsatile left ventricle and continuous-flow generated by the LVAD. Flow-through the LVAD is dependent on the interaction between device and patient-specific factors with suboptimal flow patterns evoking increased risk of LVAD-related complications. Computational fluid dynamics can be used to analyze how different pump and patient factors affect flow patterns in the left ventricle and the aorta. Computational fluid dynamics simulations were carried out on a patient with a HeartMate II. Simulations were also conducted for theoretical scenarios substituting HeartWare HVAD, HeartMate 3 (HM3) in continuous mode and HM3 with Artificial Pulse. An anatomical model of the patient was reconstructed from computed tomography (CT) images, and the LVAD outflow was used as the inflow boundary condition. The LVAD outflow was calculated separately using a lumped-parameter-model of the systemic circulation, which was calibrated to the patient based on the patient-specific ventricular volume change reconstructed from 4 dimensional computed tomography and pulmonary capillary wedge pressure tracings. The LVADs were implemented in the lumped-parameter-model via published pressure head versus flow (H-Q) curves. To quantify the flushing effect, virtual contrast agent was released in the ascending aorta and its flushing over the cycles was quantified. Shear stress acting on the aortic endothelium and shear rate in the bloodstream were also quantified as indicators of normal/abnormal blood flow, especially the latter being a biomarker of platelet activation and hemolysis. LVAD speeds for the HVAD and HM3 were selected to match flow rates for the patient's HMII (9,000 RPM for HMII, 5,500 RPM for HM3, and 2,200 RPM for HVAD), the cardiac outputs were 5.81 L/min, 5.83 L/min, and 5.92 L/min, respectively. The velocity of blood flow in the outflow cannula was higher in the HVAD than in the two HeartMate pumps with a cycle average (range) of 0.92 m/s (0.78-1.19 m/s), 0.91 m/s (0.86-1.00 m/s), and 1.74 m/s (1.40-2.24 m/s) for HMII, HM3, and HVAD, respectively. Artificial pulse increased the peak flow rate to 9.84 L/min for the HM3 but the overall cardiac output was 5.96 L/min, which was similar to the continuous mode. Artificial pulse markedly decreased blood stagnation in the ascending aorta; after six cardiac cycles, 48% of the blood was flushed out from the ascending aorta under the continuous operation mode while 60% was flushed under artificial pulse. Shear stress and shear rate in the aortic arch were higher with the HVAD compared to the HMII and HM3, respectively (shear stress: 1.76 vs. 1.33 vs. 1.33 Pa, shear rate: 136 vs. 91.5 vs. 89.4 s(-1)). Pump-specific factors such as LVAD type and programmed flow algorithms lead to unique flow patterns which influence blood stagnation, shear stress, and platelet activation. The pump-patient interaction can be studied using a novel computational fluid dynamics model to better understand and potentially mitigate the risk of downstream LVAD complications.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [21] Left ventricular assist device thrombosis in the setting of left ventricular recovery
    Hurst, Thomas E.
    Moazami, Nader
    Starling, Randall C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : 622 - 623
  • [22] Impact of perioperative right ventricular assist device on ventricular arrhythmias in patients with continuous flow left ventricular assist device
    Dhawan, R.
    Selim, A.
    Jhand, A.
    Lundgren, S.
    Zolty, R.
    Khan, F.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1096 - 1096
  • [23] Reduced Pulsatility During Continuous Flow Left Ventricular Assist Device Does Not Affect Kidney Function
    Gallo, M.
    Valadon, C. L.
    Trivedi, J. R.
    Slaughter, M. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S118 - S118
  • [24] A Novel Risk Model to Predict Right Ventricular Failure after Continuous Flow Left Ventricular Assist Device Implantation
    Loforte, A.
    Montalto, A.
    Musumeci, F.
    Mariani, C.
    Polizzi, V.
    Della Monica, P. Lilla
    Grigioni, F.
    Marinelli, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S370 - S370
  • [25] A novel phonetic approach to continuous flow left ventricular assist device auscultation
    Araj, Faris G.
    Cox, Julie
    Amin, Alpesh A.
    Mammen, Pradeep P. A.
    HEART & LUNG, 2021, 50 (06): : 780 - 783
  • [26] Impact of a continuous flow left ventricular assist device on right ventricular function
    Murthy, Raghav
    Morgan, Jeffrey
    Brewer, Robert
    Nemeh, Hassan
    Henry, Scott
    Williams, Celeste
    Lanfear, David
    Tita, Cristina
    Sabbah, Hani
    Paone, Gaetano
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2010, 211 (03) : S31 - S32
  • [27] Asymptomatic ventricular fibrillation in continuous flow left-ventricular assist device
    Smith, Moira E.
    Moak, James H.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 49 : 130 - 132
  • [28] Ventricular Arrhythmias in Patients With a Continuous-Flow Left Ventricular Assist Device
    Yap, Sing-Chien
    Ramjankhan, Faiz
    de Jonge, Rahat Muslem Nicolaas
    Kirkels, Hans J.
    Akin, Sakir
    Manintveld, Olivier C.
    Birim, Ozcan
    Szili-Torok, Tamas
    Caliskan, Kadir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (03) : 323 - 325
  • [29] Ventricular Standstill in a Patient With a Left Ventricular Assist Device
    Fukunaga, Naoto
    Nedadur, Rashmi
    Badiwala, Mitesh V.
    Billia, Filio
    McDonald, Michael A.
    Rao, Vivek
    ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E153 - E155
  • [30] Left Ventricular Assist Device in Right Ventricular Failure
    Parwani, P.
    Gowd, B. M. P.
    Nahar, R.
    Statz, C.
    O'Sullivan, D.
    Chomick, N.
    Radojevic, J.
    Gluck, J.
    Hammond, J.
    Wencker, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S83 - S83