A high-accuracy polynomial fitting approach to determine contact angles

被引:104
|
作者
Bateni, A
Susnar, SS
Amirfazli, A
Neumann, AW
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Alberta, Dept Mech Engn, Edmonton, AB T6G 2G8, Canada
关键词
contact angle; drop shape; polynomial fitting; image processing; surface tension;
D O I
10.1016/S0927-7757(03)00053-0
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An automated polynomial fitting (APF) scheme is presented for high-accuracy contact angle measurements. The APF method acquires highly magnified (e.g. 35 x) images of a drop and extracts the drop profile using image processing techniques. Then a polynomial is fitted to the experimentally observed drop profile and the contact angle is calculated using the slope of the polynomial at the contact point. Different edge detection techniques were examined and it was found that the Laplacian of Gaussian edge detection method performs well for the highly magnified images. A thorough statistical analysis was carried out to determine the optimum parameters for the curve fitting e.g., the order of the polynomial and the number of pixels used in the fitting procedure. A comparison of the APF method with Axisymmetric Drop Shape Analysis (ADSA) indicates good agreement between the two methods. The APF method is applicable to a variety of situations, e.g., liquid lens systems, non-axisymmetric drops, and electrically charged drops, where application of traditional contact angle measurement methods may not be accurate enough. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 231
页数:17
相关论文
共 50 条
  • [31] A HIGH-ACCURACY MODEL REDUCTION FOR ANALYSIS OF NONLINEAR VIBRATIONS IN STRUCTURES WITH CONTACT INTERFACES
    Petrov, E. P.
    PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 6, PTS A AND B, 2010, : 1025 - 1037
  • [32] A High-Accuracy Model Reduction for Analysis of Nonlinear Vibrations in Structures With Contact Interfaces
    Petrov, E. P.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (10):
  • [33] Statistical patterns: an approach for high-speed and high-accuracy shape measurements
    Schaffer, Martin
    Grosse, Marcus
    Harendt, Bastian
    Kowarschik, Richard
    OPTICAL ENGINEERING, 2014, 53 (11)
  • [34] Trigonometric Polynomial or Exponential Fitting Approach?
    Vanden Berghe, G.
    Van Daele, M.
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, 2008, 1048 : 1002 - 1005
  • [35] Trigonometric polynomial or exponential fitting approach?
    Vanden Berghe, G.
    Van Daele, M.
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2009, 233 (04) : 969 - 979
  • [36] HIGH-ACCURACY SHF HYGROMETER
    LEBEDEV, IV
    METSNER, EP
    POTAPOV, AA
    MEASUREMENT TECHNIQUES USSR, 1985, 28 (07): : 674 - 676
  • [37] HIGH-ACCURACY STRAIGHTENING OF TUBES
    KARASEVICH, PP
    SAVCHENKO, YV
    RASIN, GV
    STOLOVITSKII, VI
    STEEL IN THE USSR, 1986, 16 (08): : 392 - 393
  • [38] HIGH-ACCURACY BATTERY TIMER
    MITCHELL, KW
    ELECTRONIC ENGINEERING, 1980, 52 (639): : 29 - 29
  • [39] High-accuracy moisture meter
    不详
    PROFESSIONAL ENGINEERING, 2001, 14 (22) : 44 - 44
  • [40] High-accuracy corneal topographer
    Rottenkolber, M
    Podbielska, H
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 : 92 - 98