High-dose-rate brachytherapy with surface applicator in penile cancer

被引:1
|
作者
Saldi, Simonetta [1 ]
Zucchetti, Claudio [2 ]
Fulcheri, Christian Paolo Luca [2 ]
Saccia, Stefano [1 ]
Ali, Emanuele [3 ,4 ]
Marani, Simona [3 ,4 ]
Ingrosso, Gianluca [3 ,4 ]
Aristei, Cynthia [3 ,4 ]
机构
[1] Perugia Gen Hosp, Sect Radiat Oncol, Perugia, Italy
[2] Perugia Gen Hosp, Med Phys, Perugia, Italy
[3] Univ Perugia, Dept Surg & Biomed Sci, Radiat Oncol, Perugia, Italy
[4] Perugia Gen Hosp, Perugia, Italy
关键词
Penile Cancer; Surface Brachytherapy; 3D Custom applicator; Thermoplastic Custom Applicator; Noninvasive Technique; RADIATION-THERAPY; PREVALENCE; MANAGEMENT; INFECTION;
D O I
10.1016/j.brachy.2021.03.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: An alternative to surgery for penile cancer is radiation therapy which is administered with external beam techniques and/or brachytherapy (BT) either interstitial or using a surface applicator. Here we report our experience in penile cancer patients treated with high-dose-rate (HDR)-BT with the surface technique, analyzing dosimetric parameters and clinical outcomes. METHODS AND MATERIALS: Between June 2016 and December 2019, 7 patients with squa-mous cell carcinoma of the penis received HDR-BT by means of customized applicators that were constructed using a 3D printer or thermoplastic mask. The total dose was 57 Gy in 19 fractions. RESULTS: Median clinical target volume percentage receiving 95%, 125%, and 150% of the prescribed dose were 93.1% (range 92.2-98.5), 12% (range 7.4-32.2), and 0.24% (range 0-10.8), respectively. Median urethral volumes receiving 90% and 115% of the prescribed dose were 40.2% (range 21.0-83.8) and 0% (range 0-1), respectively. All patients achieved complete remission. No patient developed G3 or G4 acute or late toxicities. No patient experienced urethral stenosis. CONCLUSIONS: Surface HDR-BT in penile cancer is feasible and is associated with a high tolerance profile and good outcomes. (c) 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 50 条
  • [1] High-dose-rate brachytherapy for localized penile cancer: Evolution of a technique
    Marban, Marina
    Crook, Juanita
    Keyes, Mira
    Dubash, Rustom
    Batchelar, Deidre
    [J]. BRACHYTHERAPY, 2020, 19 (02) : 201 - 209
  • [2] Organ sparing treatment for penile cancer using a 3D-printed high-dose-rate brachytherapy applicator
    Lee, Hugh H. C.
    Chiu, Tsuicheng D.
    Hrycushko, Brian
    Xiong, Zhenyu
    Hudak, Steve
    Woldu, Solomon
    Mauck, Ryan
    Corwin, Terry
    Meng, Xiaosong
    Margulis, Vitaly
    Desai, Neil
    Folkert, Michael R.
    Garant, Aurelie
    [J]. BRACHYTHERAPY, 2023, 22 (05) : 580 - 585
  • [3] 3D-printed surface mould applicator for high-dose-rate brachytherapy
    Schumacher, Mark
    Lasso, Andras
    Cumming, Ian
    Rankin, Adam
    Falkson, Conrad B.
    Schreiner, L. John
    Joshi, Chandra
    Fichtinger, Gabor
    [J]. MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [4] Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer
    Yoshida, Ken
    Yamazaki, Hideya
    Nose, Takayuki
    Shiomi, Hiroya
    Yoshida, Mineo
    Mikami, Mari
    Takenaka, Tadashi
    Kotsuma, Tadayuki
    Tanaka, Eiichi
    Kuriyama, Keiko
    Harada, Yasunori
    Tohda, Akira
    Yasunaga, Yutaka
    Oka, Toshitsugu
    [J]. BRACHYTHERAPY, 2010, 9 (01) : 36 - 41
  • [5] High-dose-rate surface brachytherapy for basal cell cancer
    Wojcieszek, P.
    Szlag, M.
    Cholewka, A.
    Kellas-Sleczka, S.
    Pruefer, A.
    Fijalkowski, M.
    Bialas, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S42 - S43
  • [6] Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer
    Buzurovic, Ivan M.
    Hansen, Jorgen L.
    Bhagwat, Mandar S.
    O'Farrell, Desmond A.
    Friesen, Scott
    Harris, Thomas C.
    Damato, Antonio L.
    Cormack, Robert A.
    Martin, Neil E.
    Devlin, Phillip M.
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (04) : 319 - 325
  • [7] High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma
    Petera, J
    Odrázka, K
    Zouhar, M
    Bedrosová, J
    Dolezel, M
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 (02) : 123 - 125
  • [8] Clinical outcomes following high-dose-rate surface applicator brachytherapy for angiosarcoma of scalp and face
    Mitra, Devarati
    Devlin, Phillip M.
    Buzurovic, Ivan
    Thornton, Katherine
    Lam, Allen C.
    Raut, Chandrajit P.
    Baldini, Elizabeth H.
    Lam, Miranda B.
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (02) : 172 - 178
  • [9] Evaluation of the surface radiation dose and dose gradient in early stage breast cancer using high-dose-rate brachytherapy MammoSite™ applicator
    Sadeghi, Amir
    Prestidge, Bradley
    Lee, Jui-Min
    Rosenthal, Arthur
    [J]. BRACHYTHERAPY, 2006, 5 (04) : 230 - 234
  • [10] Novel portable apparatus for outpatient high-dose-rate (HDR) brachytherapy in penile cancer
    Rishi, Anupam
    Saini, Amarjit S.
    Spiess, Philippe E.
    Yu, Alice
    Fernandez, Daniel C.
    Johnstone, Peter A. S.
    Naghavi, Arash O.
    [J]. BRACHYTHERAPY, 2022, 21 (06) : 839 - 847