Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer

被引:36
|
作者
Yoshida, Ken [1 ]
Yamazaki, Hideya [2 ]
Nose, Takayuki [3 ]
Shiomi, Hiroya [4 ]
Yoshida, Mineo
Mikami, Mari
Takenaka, Tadashi
Kotsuma, Tadayuki
Tanaka, Eiichi
Kuriyama, Keiko
Harada, Yasunori [5 ]
Tohda, Akira [5 ]
Yasunaga, Yutaka [5 ]
Oka, Toshitsugu [5 ]
机构
[1] Osaka Natl Hosp, Natl Hosp Org, Dept Radiol, Chuo Ku, Osaka 5400006, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto, Japan
[3] Canc Inst Hosp, Dept Radiat Oncol, Tokyo, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, Osaka, Japan
[5] Osaka Natl Hosp, Natl Hosp Org, Dept Urol, Osaka 5400006, Japan
关键词
Applicator displacement; Ambulatory technique; High-dose-rate interstitial brachytherapy; Prostate cancer; HDR BRACHYTHERAPY; EXTERNAL-BEAM; MONOTHERAPY; CATHETER; FEASIBILITY; FRACTIONS; MOVEMENT;
D O I
10.1016/j.brachy.2009.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To introduce an effective ambulatory technique in high-dose-rate interstitial brachytherapy (HDR-ISBT) for prostate cancer, we investigated the displacement distance using our novel calculation method. METHODS AND MATERIALS: Sixty-four patients treated with HDR-ISBT as monotherapy were examined. Of these, 4, 17, and 43 patients were administered treatment doses of 38 Gy (3 days), 49 Gy (4 days), and 54 Gy (5 days), respectively. For dose administration, we used 776 flexible applicators with a removable template (ambulatory technique). Using CT images, we calculated the relative coordinates of the metal markers and applicators. From these coordinates, to analyze displacement during treatment, we measured the distance between the tip of the needle applicator and the center of gravity of the markers along the average applicator vector. RESULTS: The median displacement distance for all applicators was 7 mm (range, -14 to 24), and that of each treatment schedule was 4, 6, and 9 mm for 38, 49, and 54 Gy, respectively. Of the 776 applicators, displacement of >10 mm was seen in 198 (26%) applicators and >15 mm in 57 (7%) applicators. Body height (p < 0.0001) and anticoagulant usage (p < 0.0001) were significant factors influencing displacement. CONCLUSIONS: We investigated needle applicator displacement using our unique method. Additional cranial margins are necessary if there is no repositioning of the dwell position. CT scanning should be performed daily during treatment for checking the position of the applicator to detect and rectify the issue of displacement. (C) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [1] Assessment of Daily Needle Applicator Displacement during High-Dose-Rate Interstitial Brachytherapy for Prostate Cancer using Daily CT Examinations
    Takenaka, Tadashi
    Yoshida, Ken
    Ueda, Mari
    Yamazaki, Hideya
    Miyake, Shunsuke
    Tanaka, Eiichi
    Yoshida, Mineo
    Yoshimura, Yasushi
    Oka, Toshitsugu
    Honda, Kazuya
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (03) : 469 - 474
  • [2] Daily CT Measurement of Needle Applicator Displacement during Multifractionated High-dose-rate Interstitial Brachytherapy for Postoperative Recurrent Uterine Cancer
    Yoshida, Ken
    Ueda, Mari
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Aramoto, Kazumasa
    Miyake, Shunsuke
    Koretsune, Yukihiro
    Ban, Chiaki
    Tanaka, Eiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (02) : 295 - 300
  • [3] Characterizing Needle Applicator Displacement for Gynecological High-Dose-Rate Interstitial Treatment
    Taylor, W.
    Carlson, M.
    Quick, A.
    Gupta, N.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Daily computed tomography measurement of needle applicator displacement during high-dose-rate interstitial brachytherapy for previously untreated uterine cervical cancer
    Mikami, Mari
    Yoshida, Ken
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Yoshida, Mineo
    Aramoto, Kazumasa
    Yamada, Shigetoshi
    Ban, Chiaki
    Tanaka, Eiichi
    Honda, Kazuya
    [J]. BRACHYTHERAPY, 2011, 10 (04) : 318 - 324
  • [5] Analysis of needle displacement during high dose rate brachytherapy for prostate cancer
    Uemae, M.
    Satoh, T.
    Kitano, M.
    Ishiyama, H.
    Kotani, S.
    Fujita, T.
    Niibe, Y.
    Ishii, T.
    Egawa, T.
    Shutou, N.
    Baba, S.
    Hayakawa, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S469 - S469
  • [6] Dosimetric effect of interfractional needle displacement in prostate high-dose-rate brachytherapy
    Kovalchuk, Nataliya
    Furutani, Keith M.
    MacDonald, O. Kenneth
    Pisansky, Thomas M.
    [J]. BRACHYTHERAPY, 2012, 11 (02) : 111 - 118
  • [7] High-Dose-Rate Interstitial Brachytherapy as Monotherapy in Prostate Cancer Patients
    Kazberuk, D.
    Filipowski, T.
    Szmigiel-Trzcinska, A.
    Niksa, M.
    Hempel, D.
    Pancewicz-Janczuk, B.
    Nowik, W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S448 - S448
  • [8] High-dose-rate brachytherapy with surface applicator in penile cancer
    Saldi, Simonetta
    Zucchetti, Claudio
    Fulcheri, Christian Paolo Luca
    Saccia, Stefano
    Ali, Emanuele
    Marani, Simona
    Ingrosso, Gianluca
    Aristei, Cynthia
    [J]. BRACHYTHERAPY, 2021, 20 (04) : 835 - 841
  • [9] Interstitial high-dose-rate brachytherapy in eyelid cancer
    Mareco, Virginia
    Bujor, Laurentiu
    Abrunhosa-Branquinho, Andre N.
    Ferreira, Miguel Reis
    Ribeiro, Tiago
    Vasconcelos, Ana Luisa
    Ferreira, Cidalina Reis
    Jorge, Marilia
    [J]. BRACHYTHERAPY, 2015, 14 (04) : 554 - 564
  • [10] Deep learning for automated applicator reconstruction in high-dose-rate prostate brachytherapy
    Deufel, C.
    Weishaupt, L.
    Sayed, H. Kamal
    Choo, C.
    Stish, B.