Assessment of Daily Needle Applicator Displacement during High-Dose-Rate Interstitial Brachytherapy for Prostate Cancer using Daily CT Examinations

被引:8
|
作者
Takenaka, Tadashi [2 ]
Yoshida, Ken [1 ,3 ]
Ueda, Mari [2 ]
Yamazaki, Hideya [4 ]
Miyake, Shunsuke [2 ]
Tanaka, Eiichi [1 ]
Yoshida, Mineo [1 ]
Yoshimura, Yasushi [2 ]
Oka, Toshitsugu [5 ]
Honda, Kazuya [2 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiat Oncol, Osaka, Japan
[2] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, Osaka 5400006, Japan
[3] Natl Hosp Org Osaka Natl Hosp, Inst Clin Res, Osaka, Japan
[4] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto 602, Japan
[5] Natl Hosp Org Osaka Natl Hosp, Dept Urol, Osaka, Japan
关键词
Applicator displacement; High-dose-rate; Interstitial brachytherapy; Prostate cancer; HDR BRACHYTHERAPY; CATHETER MOVEMENT; EXTERNAL-BEAM; MONOTHERAPY; FRACTIONS;
D O I
10.1269/jrr.11168
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To improve treatment conformity for prostate cancer, we investigated daily applicator displacement during high-dose-rate interstitial brachytherapy (HDR-ISBT). Thirty patients treated with HDR-ISBT as monotherapy were examined. All patients received a treatment dosage of 49 Gy per 7 fractions over 4 days. For dose administration, we examined 376 flexible applicators (1128 points) using our unique ambulatory implant technique. Using CT images with a 3-mm slice thickness, we calculated the relative coordinates of the titanium markers and the tips of the applicators. We calculated the distance between the center of gravity of the markers and the tips of the catheters, and compared the distances measured on the day of implantation and the second, third, and fourth treatment days. The mean displacement distance for all applicators was 4.3 +/- 3.4 mm, 4.6 +/- 4.1 mm, and 5.8 +/- 4.5 mm at 21, 45, and 69 hours after initial planning CT. We used a 15-mm margin for needle displacement and only 2 points of 2 patients (16 mm and 18 mm at 69 hours, 2/1128 = 0.2%) exceeded this range. Almost patients (87%) showed the largest displacement within the first 21 hours. The relative doses that covered 100% of CTV (D100(CTV)) values compared with the initial treatment plan were reduced to 0.96 +/- 0.08, 0.96 +/- 0.08 and 0.94 +/- 0.1 at 21, 45 and 69 hours. However, the relative D90(CTV) values kept acceptable levels (1.01 +/- 0.02, 1.01 +/- 0.03 and 1.01 +/- 0.03). Cranial margin of 15 mm seems to be effective to keep D90(CTV) level if we do not do corrective action.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 50 条
  • [1] Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer
    Yoshida, Ken
    Yamazaki, Hideya
    Nose, Takayuki
    Shiomi, Hiroya
    Yoshida, Mineo
    Mikami, Mari
    Takenaka, Tadashi
    Kotsuma, Tadayuki
    Tanaka, Eiichi
    Kuriyama, Keiko
    Harada, Yasunori
    Tohda, Akira
    Yasunaga, Yutaka
    Oka, Toshitsugu
    [J]. BRACHYTHERAPY, 2010, 9 (01) : 36 - 41
  • [2] Daily CT Measurement of Needle Applicator Displacement during Multifractionated High-dose-rate Interstitial Brachytherapy for Postoperative Recurrent Uterine Cancer
    Yoshida, Ken
    Ueda, Mari
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Aramoto, Kazumasa
    Miyake, Shunsuke
    Koretsune, Yukihiro
    Ban, Chiaki
    Tanaka, Eiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (02) : 295 - 300
  • [3] Daily computed tomography measurement of needle applicator displacement during high-dose-rate interstitial brachytherapy for previously untreated uterine cervical cancer
    Mikami, Mari
    Yoshida, Ken
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Yoshida, Mineo
    Aramoto, Kazumasa
    Yamada, Shigetoshi
    Ban, Chiaki
    Tanaka, Eiichi
    Honda, Kazuya
    [J]. BRACHYTHERAPY, 2011, 10 (04) : 318 - 324
  • [4] Assessment of Daily Replanning and Geometrical Variation of High-dose-rate Brachytherapy for the Prostate
    Uchida, Hirofumi
    Hirata, Takero
    Otani, Keisuke
    Suzuki, Osamu
    Oda, Michio
    Akino, Yuichi
    Sumida, Iori
    Hatano, Koji
    Fujita, Kazutoshi
    Uemura, Motohide
    Imamura, Ryoichi
    Eino, Daisuke
    Yoshioka, Yasuo
    Nonomura, Norio
    Ogawa, Kazuhiko
    [J]. ANTICANCER RESEARCH, 2020, 40 (03) : 1677 - 1682
  • [5] Characterizing Needle Applicator Displacement for Gynecological High-Dose-Rate Interstitial Treatment
    Taylor, W.
    Carlson, M.
    Quick, A.
    Gupta, N.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [6] Analysis of needle displacement during high dose rate brachytherapy for prostate cancer
    Uemae, M.
    Satoh, T.
    Kitano, M.
    Ishiyama, H.
    Kotani, S.
    Fujita, T.
    Niibe, Y.
    Ishii, T.
    Egawa, T.
    Shutou, N.
    Baba, S.
    Hayakawa, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S469 - S469
  • [7] Dosimetric effect of interfractional needle displacement in prostate high-dose-rate brachytherapy
    Kovalchuk, Nataliya
    Furutani, Keith M.
    MacDonald, O. Kenneth
    Pisansky, Thomas M.
    [J]. BRACHYTHERAPY, 2012, 11 (02) : 111 - 118
  • [8] High-Dose-Rate Interstitial Brachytherapy as Monotherapy in Prostate Cancer Patients
    Kazberuk, D.
    Filipowski, T.
    Szmigiel-Trzcinska, A.
    Niksa, M.
    Hempel, D.
    Pancewicz-Janczuk, B.
    Nowik, W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S448 - S448
  • [9] High-dose-rate brachytherapy with surface applicator in penile cancer
    Saldi, Simonetta
    Zucchetti, Claudio
    Fulcheri, Christian Paolo Luca
    Saccia, Stefano
    Ali, Emanuele
    Marani, Simona
    Ingrosso, Gianluca
    Aristei, Cynthia
    [J]. BRACHYTHERAPY, 2021, 20 (04) : 835 - 841
  • [10] Multifractionated high-dose-rate brachytherapy with concomitant daily teletherapy for cervical cancer
    Han, I
    Malviya, V
    Chuba, P
    Orton, C
    Devi, S
    Deppe, G
    Malone, J
    Christensen, C
    Ahmad, K
    Kim, Y
    Porter, A
    [J]. GYNECOLOGIC ONCOLOGY, 1996, 63 (01) : 71 - 77