High-dose-rate brachytherapy with surface applicator in penile cancer

被引:1
|
作者
Saldi, Simonetta [1 ]
Zucchetti, Claudio [2 ]
Fulcheri, Christian Paolo Luca [2 ]
Saccia, Stefano [1 ]
Ali, Emanuele [3 ,4 ]
Marani, Simona [3 ,4 ]
Ingrosso, Gianluca [3 ,4 ]
Aristei, Cynthia [3 ,4 ]
机构
[1] Perugia Gen Hosp, Sect Radiat Oncol, Perugia, Italy
[2] Perugia Gen Hosp, Med Phys, Perugia, Italy
[3] Univ Perugia, Dept Surg & Biomed Sci, Radiat Oncol, Perugia, Italy
[4] Perugia Gen Hosp, Perugia, Italy
关键词
Penile Cancer; Surface Brachytherapy; 3D Custom applicator; Thermoplastic Custom Applicator; Noninvasive Technique; RADIATION-THERAPY; PREVALENCE; MANAGEMENT; INFECTION;
D O I
10.1016/j.brachy.2021.03.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: An alternative to surgery for penile cancer is radiation therapy which is administered with external beam techniques and/or brachytherapy (BT) either interstitial or using a surface applicator. Here we report our experience in penile cancer patients treated with high-dose-rate (HDR)-BT with the surface technique, analyzing dosimetric parameters and clinical outcomes. METHODS AND MATERIALS: Between June 2016 and December 2019, 7 patients with squa-mous cell carcinoma of the penis received HDR-BT by means of customized applicators that were constructed using a 3D printer or thermoplastic mask. The total dose was 57 Gy in 19 fractions. RESULTS: Median clinical target volume percentage receiving 95%, 125%, and 150% of the prescribed dose were 93.1% (range 92.2-98.5), 12% (range 7.4-32.2), and 0.24% (range 0-10.8), respectively. Median urethral volumes receiving 90% and 115% of the prescribed dose were 40.2% (range 21.0-83.8) and 0% (range 0-1), respectively. All patients achieved complete remission. No patient developed G3 or G4 acute or late toxicities. No patient experienced urethral stenosis. CONCLUSIONS: Surface HDR-BT in penile cancer is feasible and is associated with a high tolerance profile and good outcomes. (c) 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 50 条
  • [41] Modified Houdek vault applicator for high-dose-rate brachytherapy: a technical report and case series
    Krishnamurthy, Revathy
    Gurram, Lavanya
    Ghadi, Yogesh
    Aravindhan, Dheera
    Scaria, Libin
    Kohle, Satish
    Kadam, Sudarshan
    Chopra, Supriya
    Mahantshetty, Umesh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (06) : 649 - 654
  • [42] Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance
    Davidson, Melanie T. M.
    Yuen, Jasper
    D'Souza, David P.
    Radwan, John S.
    Hammond, J. Alex
    Batchelar, Deidre L.
    BRACHYTHERAPY, 2008, 7 (03) : 248 - 253
  • [43] Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
    Candela-Juan, C.
    Niatsetski, Y.
    van der Laarse, R.
    Granero, D.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    MEDICAL PHYSICS, 2016, 43 (04) : 1639 - 1648
  • [44] Applicator visualization using ultrashort echo time MRI for high-dose-rate endorectal brachytherapy
    van den Ende, Roy P. J.
    Ercan, Ece
    Keesman, Rick
    Kerkhof, Ellen M.
    Marijnen, Corrie A. M.
    van der Heide, Uulke A.
    BRACHYTHERAPY, 2020, 19 (05) : 618 - 623
  • [45] IMPACT OF SURFACE CURVATURE ON DOSE DELIVERY IN INTRAOPERATIVE HIGH-DOSE-RATE BRACHYTHERAPY
    Oh, Moonseong
    Wang, Zhou
    Malhotra, Harish K.
    Jaggernauth, Wainwright
    Podgorsak, Matthew B.
    MEDICAL DOSIMETRY, 2009, 34 (01) : 63 - 74
  • [46] Efficacy and cosmetic results of high-dose-rate brachytherapy with Valencia applicator for the treatment of superficial skin cancer in elderly patients
    Marin, A.
    Vargas-Diez, E.
    Delgado, Y.
    Buchser, D.
    Godoy, A.
    Concha, M. -J.
    Cerezo, L.
    Dauden, E.
    BRITISH JOURNAL OF DERMATOLOGY, 2014, 171 : 69 - 69
  • [47] Sigmoid dose delivered by high-dose-rate brachytherapy versus low-dose-rate brachytherapy for cervical cancer
    Holloway, C. L.
    O'Farrell, D. A.
    Cormack, R. A.
    Viswanathan, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S165 - S165
  • [48] Acute Toxicity of High-Dose-Rate Intracavitary Brachytherapy With the MammoSite Applicator in Patients With Early-Stage Breast Cancer
    Gregory M. Richards
    Anthony M. Berson
    John Rescigno
    Seema Sanghavi
    Beth Siegel
    Deborah Axelrod
    Stephanie Bernik
    Vincent Scarpinato
    Christopher Mills
    Annals of Surgical Oncology, 2004, 11 : 739 - 746
  • [49] Acute toxicity of high-dose-rate intracavitary brachytherapy with the MarnmoSite applicator in patients with early-stage breast cancer
    Richards, GM
    Berson, AM
    Rescigno, J
    Sanghavi, S
    Siegel, B
    Axelrod, D
    Bernik, S
    Scarpinato, V
    Mills, C
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (08) : 739 - 746
  • [50] Impact of source position on high-dose-rate skin surface applicator dosimetry
    Jeong, Jeho
    Barker, Christopher A.
    Zaider, Marco
    Cohen, Gil'ad N.
    BRACHYTHERAPY, 2016, 15 (05) : 650 - 660