Three-Dimensional Magnetic Resonance Imaging Quantification of Glenoid Bone Loss Is Equivalent to 3-Dimensional Computed Tomography Quantification: Cadaveric Study

被引:33
|
作者
Yanke, Adam B. [1 ]
Shin, Jason J. [2 ]
Pearson, Ian [3 ]
Bach, Bernard R., Jr. [1 ]
Romeo, Anthony A. [1 ]
Cole, Brian J. [1 ]
Verma, Nikhil N. [1 ]
机构
[1] Rush Univ, Dept Orthopaed, Sports Med Div, Chicago, IL 60612 USA
[2] Univ Saskatchewan, Royal Univ Hosp, Dept Orthopaed, Saskatoon, SK, Canada
[3] Rush Univ, Med Sch, Chicago, IL 60612 USA
关键词
SHOULDER INSTABILITY; ARTICULAR-CARTILAGE; RADIATION-EXPOSURE; GLENOHUMERAL JOINT; MR ARTHROGRAPHY; BANKART REPAIR; DEFECT; CT; DISLOCATION; RECURRENCE;
D O I
10.1016/j.arthro.2016.08.025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To assess the ability of 3-dimensional (3D) magnetic resonance imaging (MRI, 1.5 and 3 tesla [ T]) to quantify glenoid bone loss in a cadaveric model compared with the current gold standard, 3D computed tomography (CT). Methods: Six cadaveric shoulders were used to create a bone loss model, leaving the surrounding soft tissues intact. The anteroposterior (AP) dimension of the glenoid was measured at the glenoid equator and after soft tissue layer closure the specimen underwent scanning (CT, 1.5-T MRI, and 3-T MRI) with the following methods (0%, 10%, and 25% defect by area). Raw axial data from the scans were segmented using manual mask manipulation for bone and reconstructed using Mimics software to obtain a 3D en face glenoid view. Using calibrated Digital Imaging and Communications in Medicine images, the diameter of the glenoid at the equator and the area of the glenoid defect was measured on all imaging modalities. Results: In specimens with 10% or 25% defects, no difference was detected between imaging modalities when comparing the measured defect size (10% defect P = .27, 25% defect P = .73). All 3 modalities demonstrated a strong correlation with the actual defect size (CT, rho =.97; 1.5-T MRI, rho = .93; 3-T MRI, rho = .92, P <.0001). When looking at the absolute difference between the actual and measured defect area, no significance was noted between imaging modalities (10% defect P = .34, 25% defect P =.47). The error of 3-T 3D MRI increased with increasing defect size (P = .02). Conclusions: Both 1.5- and 3-Tebased 3D MRI reconstructions of glenoid bone loss correlate with measurements from 3D CT scan data and actual defect size in a cadaveric model. Regardless of imaging modality, the error in bone loss measurement tends to increase with increased defect size. Use of 3D MRI in the setting of shoulder instability could obviate the need for CT scans. Clinical Relevance: The goal of our work was to develop a reproducible method of determining glenoid bone loss from 3D MRI data and hence eliminate the need for CT scans in this setting. This will lead to decreased cost of care as well as decreased radiation exposure to patients. The long-term goal is a fully automated system that is as approachable for clinicians as current 3D CT technology.
引用
收藏
页码:709 / 715
页数:7
相关论文
共 50 条
  • [21] Combination of Magnetic Resonance Imaging and Neutron Computed Tomography for Three-Dimensional Rhizosphere Imaging
    Haber-Pohimeler, S.
    Toetzke, S. C.
    Lehmann, E.
    Kardjilov, N.
    Pohlmeier, A.
    Oswald, S. E.
    [J]. VADOSE ZONE JOURNAL, 2019, 18 (01): : 1 - 11
  • [22] Comparison of Two Different Glenoid Bone Loss Calculation Methods using Three-Dimensional Computed Tomography
    Pawar, Abhijit D.
    Rangankar, Varsha P.
    Bhole, Priya R.
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (11) : TC01 - TC03
  • [23] Accuracy and Reliability of a Simple Calculation for Measuring Glenoid Bone Loss on 3-Dimensional Computed Tomography Scans
    Parada, Stephen A.
    Eichinger, Josef K.
    Dumont, Guillaume D.
    Parada, Carrie A.
    Greenhouse, Alyssa R.
    Provencher, Matthew T.
    Higgins, Laurence D.
    Warner, Jon J. P.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (01): : 84 - 92
  • [24] Advances in Hip Imaging: 3-Dimensional Computed Tomography, Magnetic Resonance Imaging, and Dynamic Imaging
    Mlynarek, Ryan A.
    Weber, Alexander E.
    Ross, James R.
    Bedi, Asheesh
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2015, 23 (03) : 166 - 174
  • [25] Three-dimensional quantification of regional left-ventricular dyssynchrony by magnetic resonance imaging
    Mischi, M.
    Kaklidou, F.
    Houthuizen, P.
    Aben, J-P
    Prinzen, F. W.
    Bracke, F.
    van den Bosch, H.
    Korsten, H. H. M.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2646 - 2649
  • [26] Three-dimensional imaging of the left atrium and pulmonary veins: Computed tomography or magnetic resonance imaging?
    Schwartzman, D
    Lacomis, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 132A - 132A
  • [27] Three-Dimensional Quantification of Glenoid Bone Loss in Anterior Shoulder Instability: The Anatomic Concave Surface Area Method
    Launay, Marine
    Choudhry, Muhammad Naghman
    Green, Nicholas
    Maharaj, Jashint
    Cutbush, Kenneth
    Pivonka, Peter
    Gupta, Ashish
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (06)
  • [28] COMPUTED-TOMOGRAPHY VERSUS MAGNETIC-RESONANCE-IMAGING AND 3-DIMENSIONAL APPLICATIONS
    SHANKAR, L
    MONTANERA, W
    [J]. MEDICAL CLINICS OF NORTH AMERICA, 1991, 75 (06) : 1355 - 1366
  • [29] Use of three-dimensional computed tomography for the analysis of the glenoid anatomy
    Kwon, YW
    Powell, KA
    Yum, JK
    Brems, JJ
    Iannotti, JP
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 85 - 90
  • [30] Three-dimensional quantification of alveolar bone loss in Porphyromonas gingivalis-infected mice using micro-computed tomography
    Wilensky, A
    Gabet, Y
    Yumoto, H
    Houri-Haddad, Y
    Shapira, L
    [J]. JOURNAL OF PERIODONTOLOGY, 2005, 76 (08) : 1282 - 1286