Monte Carlo dose computation for IMRT optimization

被引:48
|
作者
Laub, W [1 ]
Alber, M [1 ]
Birkner, M [1 ]
Nüsslin, F [1 ]
机构
[1] Univ Tubingen, Radiol Uniklin, Abt Med Phys, D-72076 Tubingen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 07期
关键词
D O I
10.1088/0031-9155/45/7/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method which combines the accuracy of Monte Carlo dose calculation with a finite size pencil-beam based intensity modulation optimization is presented. The pencil-beam algorithm is employed to compute the fluence element updates for a converging sequence of Monte Carlo dose distributions. The combination is shown to improve results over the pencil-beam based optimization in a lung tumour case and a head and neck case. Inhomogeneity effects like a broader penumbra and dose build-up regions can be compensated for by intensity modulation.
引用
收藏
页码:1741 / 1754
页数:14
相关论文
共 50 条
  • [1] IMRT with Monte Carlo dose computation:: what is the benefit?
    Laub, W
    Alber, M
    Birkner, M
    Nüsslin, F
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 423 - 424
  • [2] IMRT Optimization Using Monte Carlo Dose Engine: The Effect of Statistical Uncertainty
    Tian, Z.
    Jia, X.
    Graves, Y.
    Uribe-Sanchez, A.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3821 - 3821
  • [3] Dose accuracy gains by use of Monte Carlo in routine IMRT treatment optimization
    Sikora, M.
    Dohm, O.
    Tung, Z.
    Alber, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2591 - 2591
  • [4] A hybrid dose evaluation method for rapid Monte Carlo-based IMRT optimization
    Siebers, J.
    Kawrakow, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2207 - 2207
  • [5] EGS4 Monte Carlo pencil beam dose calculation for IMRT optimization
    Earl, MA
    Li, XA
    Shepard, D
    Yu, CX
    MEDICAL PHYSICS, 2002, 29 (06) : 1256 - 1256
  • [6] Monte Carlo dose calculations for dynamic IMRT treatments
    Keall, PJ
    Siebers, JV
    Arnfield, M
    Kim, JO
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 929 - 941
  • [7] MCDE: a new Monte Carlo dose engine for IMRT
    Reynaert, N
    De Smedt, B
    Coghe, M
    Paelinck, L
    Van Duyse, B
    De Gersem, W
    De Wagter, C
    De Neve, W
    Thierens, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : N235 - N241
  • [8] Development of a Monte Carlo model for dose calculations in IMRT
    Aaronson, R
    DeMarco, J
    Chetty, I
    Solberg, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1330 - 1330
  • [9] Implementation of Monte Carlo calculated beamlet dose distributions in a direct aperture optimization algorithm for IMRT
    Bergman, A
    Bush, K
    Milette, M
    Popescu, I
    Otto, K
    Duzenli, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S108 - S108
  • [10] Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system
    Ma, CM
    Pawlicki, T
    Jiang, SB
    Li, JS
    Deng, J
    Mok, E
    Kapur, A
    Xing, L
    Ma, L
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2483 - 2495