Monte Carlo dose calculations for dynamic IMRT treatments

被引:66
|
作者
Keall, PJ [1 ]
Siebers, JV [1 ]
Arnfield, M [1 ]
Kim, JO [1 ]
Mohan, R [1 ]
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia Hosp, Dept Radiat Oncol, Richmond, VA 23284 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 04期
关键词
D O I
10.1088/0031-9155/46/4/302
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose calculations for intensity modulated radiation therapy (IMRT) face new challenges due to the complex leaf geometry and time dependent nature of the delivery. A fast method of particle transport through a dynamic multileaf collimator (MLC) geometry that accounts for photon attenuation and first-scattered Compton photon production has been incorporated into an existing Monte Carlo code used for patient dose calculations. Dosimetric agreement between calculation and measurement for two photon energies and MLC types is within experimental error for the sliding window tests. For a patient IMRT field, the Monte Carlo calculations are closer to measured dose than similar superposition or pencil beam calculations.
引用
收藏
页码:929 / 941
页数:13
相关论文
共 50 条
  • [1] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Development of a Monte Carlo model for dose calculations in IMRT
    Aaronson, R
    DeMarco, J
    Chetty, I
    Solberg, T
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1330 - 1330
  • [3] Modeling a Multi Leaf Collimator for IMRT Monte Carlo Dose Calculations
    Craig, J.
    Mulligan, M.
    Chen, J.
    Wong, E.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Comparison of conventional and Monte Carlo dose calculations for prostate treatments
    Fraser, D.
    Mark, C.
    Cury, F.
    Chang, A.
    Verhaegen, F.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [5] Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT
    De Smedt, B
    Vanderstraeten, B
    Reynaert, N
    De Neve, W
    Thierens, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17): : 4005 - 4019
  • [6] Is AcurosXBTM Equivalent in Accuracy to Monte Carlo for Complex IMRT and VMAT Dose Calculations?
    Ansbacher, W.
    Bush, K.
    Gagne, I.
    Zavgorodni, S.
    Beckham, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Dynamic IMRT treatments of sinus region tumors: Comparison of Monte Carlo calculations with treatment planning system calculations and ion chamber measurements
    Chin, D.
    Jahnke, L.
    Cormack, R.
    Tishler, R.
    Court, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2220 - 2220
  • [8] Dynamic IMRT treatments of sinus region tumors: Comparison of Monte Carlo calculations with treatment planning system calculations and ion chamber measurements
    Court, Laurence E.
    Jahnke, Lennart
    Chin, David
    Song, Jun
    Cormack, Robert
    Zygmanski, Piotr
    Tishler, Roy B.
    Chin, Lee
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (05) : 489 - 495
  • [9] ELECTRON MONTE CARLO DOSE CALCULATIONS FOR BREAST TREATMENTS IMAGED WITH ULTRASOUND
    Fraser, D.
    Wong, P.
    Verhaegen, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S171 - S171
  • [10] Dynamic-MLC modeling for Monte Carlo dose calculations
    Siebers, JV
    Keall, PJ
    Arnfield, M
    Kim, JO
    Mohan, R
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 455 - 457