Magnetic Resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation in the Central Nervous System

被引:0
|
作者
Martinez, FM [1 ]
Noll, DC [1 ]
Anderson, DJ [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
MR compatibility; multichannel silicon microelectrode; neural recordings; MRI;
D O I
10.1109/CNE.2003.1196781
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Magnetic Resonance (MR) compatibility of biomedical implants and devices represents a challenge for designers and potential risks for users. This work addresses this problem and presents the first MR compatible multichannel silicon chronic microelectrode system, used for recording and electrical stimulation in the Central Nervous System of animal subjects. A standard chronic assembly was tested on a 2 Tesla magnet to detect areas of concern and modified to minimize or eliminate susceptibility artifacts, tissue damage, and electrode displacement, maintaining good image quality and safety to the animals. Multiple commercial connectors were tested for MR compatibility and several options for reference electrodes were also tested to minimize image artifacts. The required circuitry to interconnect the MR compatible microelectrode with standard data acquisition systems was also designed and fabricated. The final design is fully MR compatible and has been tested on guinea pigs.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [1] Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: Design criteria, tests, and recommendations
    Santiesteban, FMM
    Swanson, SD
    Noll, DC
    Anderson, DJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 547 - 558
  • [2] SIMPLE MICROELECTRODE FOR RECORDING FROM THE CENTRAL NERVOUS SYSTEM
    GREEN, JD
    NATURE, 1958, 182 (4640) : 962 - 962
  • [3] Magnetic stimulation of the central and peripheral nervous systems
    Weber, M
    Eisen, AA
    MUSCLE & NERVE, 2002, 25 (02) : 160 - 175
  • [4] A 256-site 3D CMOS microelectrode array for multipoint stimulation and recording in the central nervous system
    Gingerich, MD
    Hetke, JF
    Anderson, DJ
    Wise, KD
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 416 - 419
  • [5] A Computerized Microelectrode Recording to Magnetic Resonance Imaging Mapping System for Subthalamic Nucleus Deep Brain Stimulation Surgery
    Mogilner, Alon Y.
    OPERATIVE NEUROSURGERY, 2018, 14 (06) : 667 - 667
  • [6] Mechanisms of Magnetic Stimulation of Central Nervous System Neurons
    Pashut, Tamar
    Wolfus, Shuki
    Friedman, Alex
    Lavidor, Michal
    Bar-Gad, Izhar
    Yeshurun, Yosef
    Korngreen, Alon
    PLOS COMPUTATIONAL BIOLOGY, 2011, 7 (03)
  • [7] Fetal magnetic resonance imaging of the central nervous system
    Huisman, TAGM
    Wisser, J
    Martin, E
    Kubik-Huch, R
    Marincek, B
    EUROPEAN RADIOLOGY, 2002, 12 (08) : 1952 - 1961
  • [8] Magnetic resonance imaging of central nervous system inflammation
    Tourdias, T.
    Brochet, B.
    Petry, K. G.
    Dousset, V.
    REVUE NEUROLOGIQUE, 2009, 165 : S77 - S87
  • [9] Multimodal magnetic resonance imaging of the central nervous system
    Galanaud, D
    Nicoli, F
    Le Fur, Y
    Guye, A
    Ranjeva, JP
    Confort-Gouny, S
    Viout, P
    Soulier, E
    Cozzone, PJ
    BIOCHIMIE, 2003, 85 (09) : 905 - 914
  • [10] Central nervous system leukemia on magnetic resonance imaging
    Konuma, Takaaki
    Ooi, Jun
    Takahashi, Satoshi
    Tomonari, Akira
    Tsukada, Nobuhiro
    Kato, Seiko
    Kasahara, Senji
    Uchimaru, Kaoru
    Tojo, Arinobu
    INTERNAL MEDICINE, 2008, 47 (05) : 477 - 477