摘要
Magnetic Resonance (MR) compatibility of biomedical implants and devices represents a challenge for designers and potential risks for users. This work addresses this problem and presents the first MR compatible multichannel silicon chronic microelectrode system, used for recording and electrical stimulation in the Central Nervous System of animal subjects. A standard chronic assembly was tested on a 2 Tesla magnet to detect areas of concern and modified to minimize or eliminate susceptibility artifacts, tissue damage, and electrode displacement, maintaining good image quality and safety to the animals. Multiple commercial connectors were tested for MR compatibility and several options for reference electrodes were also tested to minimize image artifacts. The required circuitry to interconnect the MR compatible microelectrode with standard data acquisition systems was also designed and fabricated. The final design is fully MR compatible and has been tested on guinea pigs.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [31] NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE CENTRAL NERVOUS-SYSTEM
    MILLS, CM
    WESTERN JOURNAL OF MEDICINE, 1983, 139 (01): : 91 - 92
  • [32] IMAGING OF INFLAMMATION IN THE PERIPHERAL AND CENTRAL NERVOUS SYSTEM BY MAGNETIC RESONANCE IMAGING
    Stoll, G.
    Bendszus, M.
    NEUROSCIENCE, 2009, 158 (03) : 1151 - 1160
  • [33] Non-central nervous system fetal magnetic resonance imaging
    Whitby, Elspeth
    Wright, Peter
    SEMINARS IN FETAL & NEONATAL MEDICINE, 2015, 20 (03): : 130 - 137
  • [34] MAGNETIC-RESONANCE-IMAGING OF THE CENTRAL-NERVOUS-SYSTEM IN THE KITTEN
    YAMADA, K
    MIYAHARA, K
    SATO, M
    HIROSE, T
    YASUGI, Y
    MATSUDA, Y
    FURUHAMA, K
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1995, 57 (01): : 155 - 156
  • [35] Magnetic resonance imaging: Utilization in the management of central nervous system trauma
    Nichols, JS
    Elger, C
    Hemminger, L
    Prall, JA
    Shaver, K
    Brennan, R
    Whitaker, JB
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (03): : 520 - 523
  • [36] Proton magnetic resonance spectroscopy and magnetic resonance imaging findings in a patient with central nervous system paracoccidioidomycosis
    Faria, AV
    Dabus, GC
    Zanardi, VA
    Cendes, F
    JOURNAL OF NEUROIMAGING, 2004, 14 (04) : 377 - 379
  • [37] Central nervous system lymphoma: magnetic resonance imaging features at presentation
    Schwingel, Ricardo
    Reis, Fabiano
    Zanardi, Veronica A.
    Queiroz, Luciano S.
    Franca, Marcondes C., Jr.
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2012, 70 (02) : 97 - 101
  • [38] Central nervous system abnormalities assessed with prenatal magnetic resonance imaging
    Levine, D
    Barnes, PD
    Madsen, JR
    Abbott, J
    Mehta, T
    Edelman, RR
    OBSTETRICS AND GYNECOLOGY, 1999, 94 (06): : 1011 - 1019
  • [39] MAGNETIC-RESONANCE IMAGING OF THE CENTRAL NERVOUS-SYSTEM - AN UPDATE
    KUCHARCZYK, W
    BRANTZAWADZKI, M
    NORMAN, D
    NEWTON, TH
    WESTERN JOURNAL OF MEDICINE, 1985, 142 (01): : 54 - 62
  • [40] MAGNETIC-RESONANCE IMAGING IN CENTRAL NERVOUS-SYSTEM SARCOIDOSIS
    MILLER, DH
    KENDALL, BE
    BARTER, S
    JOHNSON, G
    MACMANUS, DG
    LOGSDAIL, SJ
    ORMEROD, IEC
    MCDONALD, WI
    NEUROLOGY, 1988, 38 (03) : 378 - 383