Study of the effect of anaesthesia on the canine ultrasonographic optic nerve sheath diameter

被引:2
|
作者
Drolet, C. [1 ]
Pinard, C. [1 ]
Gaitero, L. [1 ]
Monteith, G. [1 ]
Bateman, S. [1 ]
机构
[1] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
关键词
CEREBRAL-BLOOD-FLOW; INTRACRANIAL-PRESSURE; ISOFLURANE; MANAGEMENT; ULTRASOUND; SIGNS; TIME;
D O I
10.1111/jsap.13403
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objectives To investigate the effects of anaesthetic duration and serial anaesthetic events on optic nerve sheath diameter in a population of dogs without intracranial disease using point-of-care ultrasonography. Materials and Methods Client-owned dogs requiring advanced head imaging were prospectively enrolled. Exclusion criteria included signs of elevated intracranial pressure, glaucoma and optic nerve disease. Using a transpalpebral technique, two optic nerve sheath diameter measurements were recorded for each eye at three timepoints: following premedication, after induction within 7 minutes and before discontinuing isoflurane. Mixed model analysis was used to characterise optic nerve sheath diameter behaviour and investigate the effects of anaesthetic duration, bodyweight and anaesthetic protocol, age and sex. Results Fourteen dogs of various ages, breeds and bodyweights were enrolled. A positive linear relationship was detected between body weight and optic nerve sheath diameter. In 12 of 14 dogs, the optic nerve sheath diameter increased from measurements taken after premedication when compared to measurements taken after induction within 7 minutes. In a subset of patients, measurements subsequently decreased when anaesthetic duration exceeded 120 minutes. Age, side, sex, final body temperature, blood pressure and anaesthetic protocol did not significantly affect optic nerve sheath diameter. No significant association was noted between optic nerve sheath diameter and end-tidal carbon dioxide after induction and before discontinuing isoflurane. Clinical Significance When using point-of-care ultrasound, a transient increase in optic nerve sheath diameter occurs between premedication and within 7 minutes following induction, regardless of bodyweight. This should be taken into consideration when serial monitoring is performed.
引用
收藏
页码:1070 / 1078
页数:9
相关论文
共 50 条
  • [21] Effect of intracranial pressure on the diameter of the optic nerve sheath
    Watanabe, Arata
    Kinouchi, Hiroyuki
    Horikoshi, Toru
    Uchida, Mikito
    Ishigame, Keiichi
    JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 255 - 258
  • [22] Ultrasonographic measurement of optic nerve sheath diameter during laparoscopic surgeries in pediatric patients: An observational study
    Ray, Swarup
    Parmar, Uditi
    Dias, Raylene
    Saxen, Vishal
    Mujpurwala, Fatema
    Anu, K. A.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2025, 41 (02) : 298 - 303
  • [23] Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks
    Hirzallah, Mohammad I.
    Bose, Supratik
    Hu, Jingtong
    Maltz, Jonathan S.
    JOURNAL OF NEUROIMAGING, 2023, 33 (06) : 898 - 903
  • [24] Ultrasonographic evaluation of the diameter of the optic nerve sheath for medication of intracranial pressure: a case report
    Carrillo Esper, Raul
    Flores Rivera, Oscar Ivan
    Pena Perez, Carlos Alberto
    Carrillo Cordova, Luis Daniel
    Carrillo Cordova, Jorge Raul
    Carrillo Cordova, Carlos Alberto
    Carrillo Cordova, Dulce Maria
    GACETA MEDICA DE MEXICO, 2014, 150 (02): : 165 - 170
  • [25] Standardized Ultrasonographic Measurement of Optic Nerve Sheath Diameter in Traumatic Brain Injury Patients
    Graziano, Mario
    Sannino, Ciro
    Mottola, Francesco Ferdinando
    NEUROLOGY INDIA, 2023, 71 (04) : 792 - 792
  • [26] The effect of different pressures of pneumoperitoneum on the optic nerve sheath diameter - A prospective study
    Ponduru, Supraja
    Nanda, Ananya
    Pakhare, Vandana Patilbuwa
    Gopinath, Ramchandran
    Sangineni, Kalyani Suryadhanalakshmi
    Priyanka, R. Devi Sai
    INDIAN ANAESTHETISTS FORUM, 2023, 24 (02): : 149 - 153
  • [27] Optic nerve sheath diameter and ICP
    不详
    PEDIATRIC RESEARCH, 2017, 81 (03) : 393 - 393
  • [28] Ultrasonography of the optic nerve sheath diameter
    Simicevic, D. Sodec
    Lovrencic-Huzjan, A.
    Popovic, I. Martinic
    Cvetkovic, V. Vukovic
    Strineka, M.
    Demarin, V.
    JOURNAL OF NEUROLOGY, 2011, 258 : 225 - 225
  • [29] Sonography of the Optic Nerve Sheath Diameter
    De Bernardo, Maddalena
    Marotta, Giuseppe
    Rosa, Nicola
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (07) : 1845 - 1845
  • [30] Optic Nerve Sheath Diameter Used as Ultrasonographic Assessment of the Incidence of Raised Intracranial Pressure in Preeclampsia A Pilot Study
    Dubost, Clement
    Le Gouez, Agnes
    Jouffroy, Viridiana
    Roger-Christoph, Sandrine
    Benhamou, Dan
    Mercier, Frederic J.
    Geeraerts, Thomas
    ANESTHESIOLOGY, 2012, 116 (05) : 1066 - 1071