The effect of different pressures of pneumoperitoneum on the optic nerve sheath diameter - A prospective study

被引:0
|
作者
Ponduru, Supraja [1 ]
Nanda, Ananya [1 ]
Pakhare, Vandana Patilbuwa [1 ]
Gopinath, Ramchandran [1 ]
Sangineni, Kalyani Suryadhanalakshmi [2 ]
Priyanka, R. Devi Sai [1 ]
机构
[1] ESIC Med Coll & Hosp, Dept Anaesthesia, Hyderabad 500038, Telangana, India
[2] AIIMS, Dept Anaesthesia, Bibinagar, Telangana, India
来源
INDIAN ANAESTHETISTS FORUM | 2023年 / 24卷 / 02期
关键词
Intracranial pressure; laparoscopic surgery; pneumoperitoneum; ultrasonography; LAPAROSCOPY;
D O I
10.4103/TheIAForum.TheIAForum_107_23
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Increased intra-abdominal pressure (IAP) and carbon dioxide gas during pneumoperitoneum leads to various systemic changes involving cardiovascular, respiratory, and cerebral physiology. In our study, we aimed to investigate the effect of standard (13-15 mmHg) and low (6-8 mmHg) pressure pneumoperitoneum on optic nerve sheath diameter (ONSD) using ultrasound, which is a reflection of intracranial pressure (ICP). Patient hemodynamics, surgery duration and surgeons' comfort, and ease of performing surgery at low-pressure pneumoperitoneum were studied as secondary objectives. Materials and Methods: In this prospective double-blind randomized study, 75 patients of the American Society of Anesthesiologists physical status grades I and II, of both genders undergoing elective laparoscopic surgery, were allocated into two groups - S (standard IAP 13-15 mmHg) and L (low IAP 6-8 mmHg). ONSD acquired at different time points: before induction of anesthesia (T1), 5 min after intubation (T2), 5 min after the creation of pneumoperitoneum (T3), 5 min before desufflation (T4), and 5 min before extubation (T5). ONSD of 5 mm is taken as the cutoff value to correlate raised ICP. Continuous variables were analyzed by the Student's t-test, and categorical data were assessed by the Chi-square test. Results: There was a significant increase in ONSD with insufflation in both the groups; however, T3 is higher than the cutoff value (>5 mm) in Group S. The ONSD values at T1 (baseline) and at T2 (after intubation) were comparable between the groups, with P = 0.1855 and P = 0.8988, respectively. With pneumoperitoneum, the increase in ONSD (T3) is significantly higher in Group S than in Group L with P = 0.0022, attributing to the high IAP in Group S. Conclusion: Laparoscopic surgery with low-pressure pneumoperitoneum can be a safe approach, particularly in individuals at risk of raised ICP.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [1] The assessment of the effect of different intraabdominal pressures used for laparoscopic cholecystectomy surgery on optic nerve sheath diameter: a prospective observational cohort study
    Erturk, Tuna
    Guven, Bulent Baris
    Yilmaz, Yadigar
    Yurtsever, Fulya
    Ersoy, Aysin
    [J]. TURKISH JOURNAL OF MEDICAL SCIENCES, 2021, 51 (03) : 1338 - 1344
  • [2] The effect of robotic surgery on intraocular pressure and optic nerve sheath diameter: a prospective study
    Balkan, Bedih
    Emir, Nalan Saygi
    Demirayak, Bengi
    Cetingok, Halil
    Bayrak, Basak
    [J]. BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2021, 71 (06): : 607 - 611
  • [3] The Association Between Hyponatremia and Optic Nerve Sheath Diameter: A Prospective Study
    Duyan, Murat
    Vural, Nafis
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [4] The effect of pneumoperitoneum and Trendelenburg position on optic nerve sheath diameter in patients undergoing laparoscopic hysterectomy
    Bayramov, Tural
    Kilicaslan, Banu
    Akinci, Seda B.
    Boyraz, Gokhan
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2022, 48 (03) : 830 - 837
  • [5] Optic Nerve Sheath Diameter in Acute Liver Failure: A Prospective Cohort Study
    Cardoso, Filipe S.
    Pereira, Rui
    Moreno, Rui
    Karvellas, Constantine J.
    Germano, Nuno
    [J]. GE PORTUGUESE JOURNAL OF GASTROENTEROLOGY, 2021, 28 (03) : 170 - 178
  • [6] Optic nerve sheath diameter
    Lovrencic-Huzjan, A.
    [J]. CEREBROVASCULAR DISEASES, 2015, 39 : 4 - 4
  • [7] Study of the effect of anaesthesia on the canine ultrasonographic optic nerve sheath diameter
    Drolet, C.
    Pinard, C.
    Gaitero, L.
    Monteith, G.
    Bateman, S.
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 2021, 62 (12) : 1070 - 1078
  • [8] Effect of intracranial pressure on the diameter of the optic nerve sheath
    Watanabe, Arata
    Kinouchi, Hiroyuki
    Horikoshi, Toru
    Uchida, Mikito
    Ishigame, Keiichi
    [J]. JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 255 - 258
  • [9] Effect of epidural anesthesia on the optic nerve sheath diameter in patients with pre-eclampsia: a prospective observational study
    Park, Sun-Kyung
    Kim, Hansol
    Kim, Youngwon
    Jang, Young-Eun
    Kim, Jin-Tae
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2024,
  • [10] Effect of Reverse Trendelenburg Position Applied Before Pneumoperitoneum on Optic Nerve Sheath Diameter in Laparoscopic Bariatric Surgery: A Randomized, Controlled Study
    Solmaz, Ali
    Demirgan, Serdar
    Burcu, Buesra
    Caliskan, Ozan
    Yagci, Selma
    Yilmaz, Ozlem
    Hacim, Nadir Adnan
    [J]. BARIATRIC SURGICAL PRACTICE AND PATIENT CARE, 2024, 19 (01) : 50 - 57