The effect of different pressures of pneumoperitoneum on the optic nerve sheath diameter - A prospective study

被引:0
|
作者
Ponduru, Supraja [1 ]
Nanda, Ananya [1 ]
Pakhare, Vandana Patilbuwa [1 ]
Gopinath, Ramchandran [1 ]
Sangineni, Kalyani Suryadhanalakshmi [2 ]
Priyanka, R. Devi Sai [1 ]
机构
[1] ESIC Med Coll & Hosp, Dept Anaesthesia, Hyderabad 500038, Telangana, India
[2] AIIMS, Dept Anaesthesia, Bibinagar, Telangana, India
来源
INDIAN ANAESTHETISTS FORUM | 2023年 / 24卷 / 02期
关键词
Intracranial pressure; laparoscopic surgery; pneumoperitoneum; ultrasonography; LAPAROSCOPY;
D O I
10.4103/TheIAForum.TheIAForum_107_23
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Increased intra-abdominal pressure (IAP) and carbon dioxide gas during pneumoperitoneum leads to various systemic changes involving cardiovascular, respiratory, and cerebral physiology. In our study, we aimed to investigate the effect of standard (13-15 mmHg) and low (6-8 mmHg) pressure pneumoperitoneum on optic nerve sheath diameter (ONSD) using ultrasound, which is a reflection of intracranial pressure (ICP). Patient hemodynamics, surgery duration and surgeons' comfort, and ease of performing surgery at low-pressure pneumoperitoneum were studied as secondary objectives. Materials and Methods: In this prospective double-blind randomized study, 75 patients of the American Society of Anesthesiologists physical status grades I and II, of both genders undergoing elective laparoscopic surgery, were allocated into two groups - S (standard IAP 13-15 mmHg) and L (low IAP 6-8 mmHg). ONSD acquired at different time points: before induction of anesthesia (T1), 5 min after intubation (T2), 5 min after the creation of pneumoperitoneum (T3), 5 min before desufflation (T4), and 5 min before extubation (T5). ONSD of 5 mm is taken as the cutoff value to correlate raised ICP. Continuous variables were analyzed by the Student's t-test, and categorical data were assessed by the Chi-square test. Results: There was a significant increase in ONSD with insufflation in both the groups; however, T3 is higher than the cutoff value (>5 mm) in Group S. The ONSD values at T1 (baseline) and at T2 (after intubation) were comparable between the groups, with P = 0.1855 and P = 0.8988, respectively. With pneumoperitoneum, the increase in ONSD (T3) is significantly higher in Group S than in Group L with P = 0.0022, attributing to the high IAP in Group S. Conclusion: Laparoscopic surgery with low-pressure pneumoperitoneum can be a safe approach, particularly in individuals at risk of raised ICP.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [41] Effect of Percutaneous Tracheostomy on Optic Nerve Sheath Diameter [TONS Trial]
    Kapoor, Indu
    Wanchoo, Jaya
    Mahajan, Charu
    Singhal, Vasudha
    Roy, Hirok
    Kumar, Subodh
    Brahma, Rupali
    Prasad, Chandrakant
    Kalaivani, Mani
    Prabhakar, Hemanshu
    Chaturvedi, Arvind
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (04) : 382 - 387
  • [42] Effect of Percutaneous Tracheostomy on Optic Nerve Sheath Diameter (TONS Trial)
    Di Paola, Ilenia
    Graziano, Mario
    Cornetta, Palmiro
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 26 (05) : 651 - 651
  • [43] Effect of a cervical collar on optic nerve sheath diameter in trauma patients
    Mümin Murat Yazici
    ?zcan Yava?i
    [J]. World Journal of Emergency Medicine, 2024, 15 (02) : 126 - 130
  • [44] Ultrasound optic nerve sheath diameter measurement in optic neuritis
    De Bernardo, Maddalena
    Vitiello, Livio
    Kumar, Akshay
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (08): : 1595 - 1596
  • [45] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    [J]. PLOS ONE, 2020, 15 (02):
  • [46] The Effect of Different Posture on Normal Saline Injection in Optic Nerve Sheath Diameter in Thoracic Epidural Anesthesia
    Park, JiHoon
    Hong, JiHee
    Kim, Jiseob
    Yi, SeungWon
    [J]. PAIN PHYSICIAN, 2020, 23 (06) : 573 - 579
  • [47] Pediatric optic nerve and optic nerve sheath diameter on magnetic resonance imaging
    Janthanimi, Pun
    Dumrongpisutikul, Netsiri
    [J]. PEDIATRIC RADIOLOGY, 2019, 49 (08) : 1071 - 1077
  • [48] Pediatric optic nerve and optic nerve sheath diameter on magnetic resonance imaging
    Pun Janthanimi
    Netsiri Dumrongpisutikul
    [J]. Pediatric Radiology, 2019, 49 : 1071 - 1077
  • [49] Research trends in optic nerve sheath diameter monitoring - A bibliometric study
    Magoon, Rohan
    Jose, Jes
    Suresh, Varun
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (06) : 579 - 582
  • [50] The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions
    Zhu, Sha
    Cheng, Chao
    Zhao, Dianjiang
    Zhao, Yuanli
    Liu, Xianzeng
    Zhang, Jun
    [J]. BMC NEUROLOGY, 2021, 21 (01)