The value of automated breast volume scanner combined with virtual touch tissue quantification in the differential diagnosis of benign and malignant breast lesions A comparative study with mammography

被引:12
|
作者
Wang, Junli [1 ]
Fan, Hongjie [2 ]
Zhu, Yuting [1 ]
Shen, Chunyun [1 ]
Qiang, Banghong [1 ]
机构
[1] Wuhu 2 Peoples Hosp, Dept Ultrasound, Wuhu 241001, Anhui, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Radiol, Sch Med, Hangzhou 310016, Zhejiang, Peoples R China
关键词
automated breast volume scanner; breast lesions; mammography; virtual touch tissue quantification; SHEAR-WAVE ELASTOGRAPHY; HAND-HELD ULTRASOUND; FORCE IMPULSE ARFI; CANCER; DENSE; US; PERFORMANCE; MASSES; WOMEN;
D O I
10.1097/MD.0000000000025568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to evaluate the diagnostic value of automated breast volume scanner (ABVS) combined with virtual touch tissue quantification (VTQ) in the differential diagnosis of breast lesions. In this retrospective study, 183 patients (mean age, 49.8 +/- 8.2 years) with 218 breast lesions underwent ABVS, VTQ, and mammography (MG). All lesions were confirmed by postoperative histopathology. A logistic regression model was constructed to generate a receiver operating characteristic (ROC) curve, calculate the area under the ROC curve (AUC), and compare and evaluate the diagnostic performance of ABVS, VTQ, MG, and ABVS combined with VTQ (ABVS-VTQ). The sensitivity, specificity, and accuracy of ABVS, VTQ, MG, and ABVS-VTQ in diagnosing breast lesions were 94.01% (110/117), 96.03% (97/101), and 94.95% (207/218); 80.34% (94/117), 94.05% (95/101), and 86.69% (189/218); 70.08% (82/117), 68.31% (69/101), and 69.26% (151/218); and 96.58% (113/117), 96.03% (97/101), and 96.33% (210/218), respectively. The AUC of ABVS-VTQ was higher than that of the other examinations alone. The detection rate of ABVS (100%, 218/218) was higher than that of MG (78.89%, 172/218), and the difference was statistically significant (chi(2) = 51.426, P < .001). The combined application of ABVS and VTQ can improve the accuracy and specificity of the diagnosis and is a promising ultrasound method for the differential diagnosis of breast lesions.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A novel application of the Automated Breast Volume Scanner (ABVS) in the diagnosis of soft tissue tumors
    Chen, Tao
    Gao, Hui
    Guo, Wen
    Qing, Xiaoting
    Gao, Kan
    Yu, Jingmiao
    Deng, Yukun
    CLINICAL IMAGING, 2015, 39 (03) : 401 - 407
  • [42] Value of diffusion weighted imaging in the differential diagnosis of benign and malignant breast lesions at 3.0T MRI
    Jiang, X. Y.
    Xie, Q. Z.
    Cao, X. S.
    Gao, T.
    Xing, C. Y.
    Li, X. L.
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (03) : 7773 - 7779
  • [43] Qualitative Evaluation of Virtual Touch Imaging Quantification: A Simple and Useful Method in the Diagnosis of Breast Lesions
    Zhu, Ying
    Jia, Xiao-hong
    Zhou, Wei
    Zhan, Wei-wei
    Zhou, Jian-qiao
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 2037 - 2045
  • [44] Value of ultrasound elastography combined with contrast-enhanced ultrasound and micro-flow imaging in differential diagnosis of benign and malignant breast lesions
    Ding, Zuopeng
    Liu, Weiyong
    He, Nianan
    Ma, Xiaopeng
    Fu, Lili
    Ye, Lei
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (12): : 13941 - 13949
  • [45] The application of Virtual Touch tissue quantification (VTQ) in diagnosis of thyroid lesions: A preliminary study
    Hou, Xiu-Juan
    Sun, Ai-Xia
    Zhou, Xian-Li
    Ji, Qiao
    Wang, Hong-Bo
    Wei, Hong
    Sun, Jia-Wei
    Liu, Han
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 797 - 801
  • [46] MYOEPITHELIAL CELLS IN THE DIFFERENTIAL-DIAGNOSIS OF COMPLEX BENIGN AND MALIGNANT BREAST-LESIONS - AN IMMUNOHISTOCHEMICAL STUDY
    GOTTLIEB, C
    RAJU, U
    GREENAWALD, KA
    MODERN PATHOLOGY, 1990, 3 (02) : 135 - 140
  • [47] Color-map virtual touch tissue imaging (CMV) combined with BI-RADS for the diagnosis of breast lesions
    Lian, Kai-Mei
    Lin, Teng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 447 - 457
  • [48] Editorial for "Radiomics Based on Multimodal MRI for the Differential Diagnosis of Benign and Malignant Breast Lesions"
    Nogueira, Luisa
    Nunes, Rita Gouveia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (02) : 608 - 609
  • [49] Value of real-time tissue elastography diffusion quantitative analysis combined with tumor markers for differential diagnosis of benign and malignant breast nodules
    Zhu, Ling
    Mei, Lina
    Pan, Xuekui
    VOJNOSANITETSKI PREGLED, 2024, 81 (11) : 673 - 680
  • [50] Combined Value of Virtual Touch Tissue Quantification and Conventional Sonographic Features for Differentiating Benign and Malignant Thyroid Nodules Smaller Than 10 mm
    Zhang, Huiping
    Shi, Qiusheng
    Gu, Jiying
    Jiang, Luying
    Bai, Min
    Liu, Long
    Wu, Ying
    Du, Lianfang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) : 257 - 264