The value of automated breast volume scanner combined with virtual touch tissue quantification in the differential diagnosis of benign and malignant breast lesions A comparative study with mammography

被引:12
|
作者
Wang, Junli [1 ]
Fan, Hongjie [2 ]
Zhu, Yuting [1 ]
Shen, Chunyun [1 ]
Qiang, Banghong [1 ]
机构
[1] Wuhu 2 Peoples Hosp, Dept Ultrasound, Wuhu 241001, Anhui, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Radiol, Sch Med, Hangzhou 310016, Zhejiang, Peoples R China
关键词
automated breast volume scanner; breast lesions; mammography; virtual touch tissue quantification; SHEAR-WAVE ELASTOGRAPHY; HAND-HELD ULTRASOUND; FORCE IMPULSE ARFI; CANCER; DENSE; US; PERFORMANCE; MASSES; WOMEN;
D O I
10.1097/MD.0000000000025568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to evaluate the diagnostic value of automated breast volume scanner (ABVS) combined with virtual touch tissue quantification (VTQ) in the differential diagnosis of breast lesions. In this retrospective study, 183 patients (mean age, 49.8 +/- 8.2 years) with 218 breast lesions underwent ABVS, VTQ, and mammography (MG). All lesions were confirmed by postoperative histopathology. A logistic regression model was constructed to generate a receiver operating characteristic (ROC) curve, calculate the area under the ROC curve (AUC), and compare and evaluate the diagnostic performance of ABVS, VTQ, MG, and ABVS combined with VTQ (ABVS-VTQ). The sensitivity, specificity, and accuracy of ABVS, VTQ, MG, and ABVS-VTQ in diagnosing breast lesions were 94.01% (110/117), 96.03% (97/101), and 94.95% (207/218); 80.34% (94/117), 94.05% (95/101), and 86.69% (189/218); 70.08% (82/117), 68.31% (69/101), and 69.26% (151/218); and 96.58% (113/117), 96.03% (97/101), and 96.33% (210/218), respectively. The AUC of ABVS-VTQ was higher than that of the other examinations alone. The detection rate of ABVS (100%, 218/218) was higher than that of MG (78.89%, 172/218), and the difference was statistically significant (chi(2) = 51.426, P < .001). The combined application of ABVS and VTQ can improve the accuracy and specificity of the diagnosis and is a promising ultrasound method for the differential diagnosis of breast lesions.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Kong, Wen-tao
    Zhou, Wei-jun
    Wang, Yin
    Zhuang, Xiao-min
    Wu, Min
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (04) : 459 - 466
  • [2] The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions
    Wen-tao Kong
    Wei-jun Zhou
    Yin Wang
    Xiao-min Zhuang
    Min Wu
    Journal of Medical Ultrasonics, 2019, 46 : 459 - 466
  • [3] Diagnostic value of virtual touch tissue imaging quantification for benign and malignant breast lesions with different sizes
    Liu, Hui
    Zhao, Li-Xia
    Xu, Guang
    Yao, Ming-Hua
    Zhang, Ai-Hong
    Xu, Hui-Xiong
    Wu, Rong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 13118 - 13126
  • [4] The value of color-map virtual touch tissue imaging (CMV) in the differential diagnosis of benign and malignant breast lesions
    Lian, Kai-Mei
    Lin, Teng
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (01) : 49 - 56
  • [5] Combination of Virtual Touch Tissue Imaging and Virtual Touch Tissue Quantification for Differential Diagnosis of Breast Lesions
    Teke, Memik
    Goya, Cemil
    Teke, Fatma
    Uslukaya, Omer
    Hamidi, Cihad
    Cetincakmak, Mehmet Guli
    Hattapoglu, Salih
    Alan, Bircan
    Tekbas, Guven
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (07) : 1201 - 1208
  • [6] Differential diagnosis of benign and malignant male breast lesions in mammography
    Huang, Yan
    Xiao, Qin
    Sun, Yiqun
    Li, Qin
    Wang, Simin
    Gu, Yajia
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [7] Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast
    Chaoli Xu
    Shuping Wei
    Yingdong Xie
    Xiaoxiang Guan
    Ninghua Fu
    Pengfei Huang
    Bin Yang
    BMC Cancer, 14
  • [8] Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast
    Xu, Chaoli
    Wei, Shuping
    Xie, Yingdong
    Guan, Xiaoxiang
    Fu, Ninghua
    Huang, Pengfei
    Yang, Bin
    BMC CANCER, 2014, 14
  • [9] Diagnostic Value of Virtual Touch Tissue Quantification for Breast Lesions with Different Size
    Yao, Minghua
    Wu, Jian
    Zou, Liling
    Xu, Guang
    Xie, Juan
    Wu, Rong
    Xu, Huixiong
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [10] Technical evaluation of Virtual Touch™ tissue quantification and elastography in benign and malignant breast tumors
    Jiang, Quan
    Zhang, Yuan
    Chen, Jian
    Zhang, Yun-Xiao
    He, Zhu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 8 (04) : 1059 - 1064