Four-dimensional aortic blood flow patterns in thoracic aortic grafts

被引:18
|
作者
Bogren, HG [1 ]
Buonocore, MH
Follette, DM
机构
[1] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Med Ctr, Dept Surg, Sacramento, CA 95817 USA
关键词
atherosclerotic aneurysm; magnetic resonance velocity mapping; thoracic aortic grafts; three-directional aortic blood-flow patterns; traumatic descending aortic pseudoaneurysm;
D O I
10.3109/10976640009146568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Time-resolved cardiac gated three-directional velocity data obtained with magnetic resonance velocity-encoded phase contrast sequences were used to study blood flow patterns in thoracic aortic grafts. Twelve patients were studied 6 with traumatic descending aortic pseudoaneurysms, 3 with atherosclerotic aneurysms, and 3 with dissecting aneurysms. All grafts had an inflow jet; outflow jet; and/or vortices proximal, in, or distal to the graft. Flow abnormalities were generally mild in the descending aortic traumatic pseudoaneurysms seen in young people. The atherosclerotic aneurysms seen in elderly patients had the most abnormal flows with multiple vortices in and outside the graft. Blood persisted up to one and a half heartbeats in some vortices and took three to five heartbeats to flow from ascending to descending aorta compared with two to three in age-matched normal subjects. Rather large energy losses, probably up to 33% of the cardiac output in our worst case, may occur in thoracic aortic grafts.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [21] Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    Hope, Thomas A.
    Markl, Michael
    Wigstrom, Lars
    Alley, Marcus T.
    Miller, D. Craig
    Herfkens, Robert J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (06) : 1471 - 1479
  • [22] Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b
    Weber, Tim F.
    Ganten, Maria-Katharina
    Boeckler, Dittmar
    Geisbuesch, Philipp
    Kopp-Schneider, Annette
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    EUROPEAN RADIOLOGY, 2009, 19 (01) : 245 - 253
  • [23] VISUALIZATION OF PERIPROCEDUAL BLOOD FLOW DYNAMICS WITH FOUR-DIMENSIONAL FLOW MAGNETIC RESONANCE IMAGING IN PATIENTS WITH SEVERE AORTIC STENOSIS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Komoriyama, Hirokazu
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    Oyama-Manabe, Noriko
    Tsuneta, Satonori
    Kobayashi, Yuta
    Kato, Yoshiya
    Omote, Kazunori
    Konishi, Takao
    Sato, Takuma
    Tsujinaga, Shingo
    Iwano, Hiroyuki
    Shingu, Yasushige
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1639 - 1639
  • [24] Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b
    Tim F. Weber
    Maria-Katharina Ganten
    Dittmar Böckler
    Philipp Geisbüsch
    Annette Kopp-Schneider
    Hans-Ulrich Kauczor
    Hendrik von Tengg-Kobligk
    European Radiology, 2009, 19 : 245 - 253
  • [25] Four-Dimensional Computed Tomography Angiography for Unclassified Endoleaks After Thoracic Endovascular Aortic Repair
    Si, Yi
    Hou, Kai
    Tang, Xiao
    Shi, Zhenyu
    Guo, Daqiao
    Fu, Weiguo
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E148 - E148
  • [26] Four-dimensional flow assessment shows coronary artery flow reversal in severe aortic regurgitation
    Garg, Mahesh Chandra
    Garg, Pankaj
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2024, 8 (04)
  • [27] Thoracic aortic stent grafts
    Milner, R
    Bavaria, JE
    Baum, RA
    Carpenter, JP
    Velazquez, OC
    Brinster, D
    Fairman, RM
    SEMINARS IN ROENTGENOLOGY, 2001, 36 (04) : 340 - 350
  • [28] Ascending-descending aortic bypass surgery in aortic arch coarctation: Four-dimensional magnetic resonance flow analysis
    Frydrychowicz, Alex
    Schlensak, Cristian
    Stalder, Aurelien F.
    Russe, Max
    Siepe, Matthias
    Beyersdorf, Friedhelm
    Langer, Mathias
    Hennig, Juergen
    Markl, Michael
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (01): : 260 - U160
  • [29] In vitro Assessment of Aortic Regurgitation using Four-Dimensional Flow Magnetic Resonance Imaging
    Kim, Doohyeon
    Huh, Hyung Kyu
    Ha, Hojin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (180):
  • [30] In vitro four-dimensional flow magnetic resonance analysis of the effect of pericardial valve design on aortic flow
    Tasca G.
    Sturla F.
    Jaworek M.
    Giese D.
    Menicanti L.
    Vismara R.
    Lombardi M.
    Redaelli A.
    Journal of Medical Engineering and Technology, 2022, 46 (03): : 209 - 219