In vitro four-dimensional flow magnetic resonance analysis of the effect of pericardial valve design on aortic flow

被引:0
|
作者
Tasca G. [1 ,2 ]
Sturla F. [2 ,3 ]
Jaworek M. [2 ]
Giese D. [4 ]
Menicanti L. [5 ]
Vismara R. [2 ]
Lombardi M. [6 ]
Redaelli A. [2 ]
机构
[1] Cardiac Surgery Department, Heart Health Center, King Saud Medical City, Riyadh
[2] Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan
[3] 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese
[4] Siemens Healthcare GmbH, Erlangen
[5] Cardiac Surgery Department, IRCCS Policlinico San Donato, San Donato Milanese
[6] Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, Milan, San Donato Milanese
来源
关键词
4D Flow; bioengineering; bioprosthetic valves; haemodynamics; in vitro analysis;
D O I
10.1080/03091902.2022.2026505
中图分类号
学科分类号
摘要
We investigated the effect of the design of bioprosthetic pericardial valves on the downstream fluid flow pattern through four-dimensional flow magnetic resonance imaging (4D Flow). A dedicated in vitro test bench, including a paradigmatic aortic root phantom, was used to compare, under steady flow conditions, three commercially used pericardial bioprostheses (TrifectaTM, Carpentier-Edwards PERIMOUNT Magna, Crown PRT®), selecting the two smallest and comparable valve sizes. In-house 4D Flow post-processing provided the downstream flow pattern of velocity, the velocity profile at vena contracta, its effective orifice area (EOA) and the corresponding hydraulic diameter (DH). Trifecta reported the lowest peak of velocity for both the tested sizes, with vena contracta position being the most proximal to the free margin of leaflets. Conversely, in both Crown and Magna, jet flow continued to increase its downstream velocity, resulting in a farther position of vena contracta. EOA shape was trilobal for Magna, triangular for Crown and circular for Trifecta, the last one maximising EOA. The percentage of nominal luminal area effectively exploited by the flow was largely above 80% in Trifecta, below 75% in Crown and below 70% in Magna. Hence, the design of pericardial bioprostheses directly impacts on the downstream flow field pattern and its fluid dynamic performance. © 2022 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:209 / 219
页数:10
相关论文
共 50 条
  • [1] Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve
    Gordon, Daniel Z.
    Abbasi, Muhannad A.
    Lee, Jeesoo
    Sarnari, Roberto
    Sojoudi, Alireza
    Wei, Qiao
    Scott, Michael B.
    Collins, Jeremy D.
    Allen, Bradley D.
    Blaisdell, Julie A.
    Carr, James C.
    Markl, Michael
    JOURNAL OF THORACIC IMAGING, 2020, 35 (06) : 383 - 388
  • [2] In vitro Assessment of Aortic Regurgitation using Four-Dimensional Flow Magnetic Resonance Imaging
    Kim, Doohyeon
    Huh, Hyung Kyu
    Ha, Hojin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (180):
  • [3] Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
    Komoriyama, Hirokazu
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    Oyama-Manabe, Noriko
    Tsuneta, Satonori
    Kobayashi, Yuta
    Kato, Yoshiya
    Sarashina, Miwa
    Omote, Kazunori
    Konishi, Takao
    Sato, Takuma
    Tsujinaga, Shingo
    Iwano, Hiroyuki
    Shingu, Yasushige
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [4] Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
    Hirokazu Komoriyama
    Kiwamu Kamiya
    Toshiyuki Nagai
    Noriko Oyama-Manabe
    Satonori Tsuneta
    Yuta Kobayashi
    Yoshiya Kato
    Miwa Sarashina
    Kazunori Omote
    Takao Konishi
    Takuma Sato
    Shingo Tsujinaga
    Hiroyuki Iwano
    Yasushige Shingu
    Satoru Wakasa
    Toshihisa Anzai
    Journal of Cardiovascular Magnetic Resonance, 23
  • [5] Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment
    Gareth T. Archer
    Alaa Elhawaz
    Natasha Barker
    Benjamin Fidock
    Alexander Rothman
    R. J. van der Geest
    Rod Hose
    Norman Briffa
    Ian R. Hall
    Ever Grech
    Malenka Bissell
    Abdallah Al-Mohammad
    Thomas A. Treibel
    Andrew J. Swift
    James M. Wild
    Pankaj Garg
    Scientific Reports, 10
  • [6] Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment
    Archer, Gareth T.
    Elhawaz, Alaa
    Barker, Natasha
    Fidock, Benjamin
    Rothman, Alexander
    van der Geest, R. J.
    Hose, Rod
    Briffa, Norman
    Hall, Ian R.
    Grech, Ever
    Bissell, Malenka
    Al-Mohammad, Abdallah
    Treibel, Thomas A.
    Swift, Andrew J.
    Wild, James M.
    Garg, Pankaj
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] Usefulness of Four-Dimensional Flow Cardiac Magnetic Resonance for Evaluation of Aortic Dissection
    Jazaeri, Omid
    Magee, Gregory
    Schaefer, Michal
    Volpe, Ross
    Rocker, Adam
    Arce, Ryan
    Hunter, Kendall S.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (02) : 552 - 552
  • [8] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Stankovic, Zoran
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (01) : 89 - 102
  • [9] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Zoran Stankovic
    World Journal of Gastroenterology, 2016, (01) : 89 - 102
  • [10] Quantification of regurgitation in mitral valve prolapse with four-dimensional flow cardiovascular magnetic resonance
    Spampinato, Ricardo A.
    Jahnke, Cosima
    Crelier, Gerard
    Lindemann, Frank
    Fahr, Florian
    Czaja-Ziolkowska, Monika
    Sieg, Franz
    Strotdrees, Elfriede
    Hindricks, Gerhard
    Borger, Michael A.
    Paetsch, Ingo
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)