A LUMPED PARAMETER MODEL OF CARDIOVASCULAR SYSTEM WITH PULSATING HEART FOR DIAGNOSTIC STUDIES

被引:13
|
作者
Frolov, S. V. [1 ]
Sindeev, S. V. [1 ]
Lischouk, V. A. [2 ]
Gazizova, D. Sh. [2 ]
Liepsch, D. [3 ]
Balasso, A. [4 ]
机构
[1] Tambov State Tech Univ, Dept Biomed Engn, Sovetskaya St 106, Tambov, Russia
[2] Bakoulev Ctr Cardiovasc Surg, Lab Math Modeling & Monitoring, Roublyevskoe Shosse 135, Moscow, Russia
[3] Munich Univ Appl Sci, Dept Bldg Serv Engn Paper & Packaging Technol & P, Lothstr 34, Munich, Germany
[4] Tech Univ Munich, Dept Neuroradiol, Klinikum Rechts Isar, Ismaninger Str 22, Munich, Germany
关键词
Cardiac modeling; patient-specific simulation; model of global hemodynamics; lumped parameter model; IN-VITRO; SIMULATION; VALIDATION;
D O I
10.1142/S0219519417500567
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mathematical modeling of cardiovascular system provides an ability to study hemodynamics and to predict the results of treatment based on individual anatomical and physiological data of patients. However, the presently developed models of cardiovascular system have a limitation on use in clinical practice due to their physical and computational complexities. The aim of this study is to derive a lumped parameter model of cardiovascular system with pulsating heart in which all parameters have a physically based quantitative value and can be identified using clinical methods. For development of a cardiovascular system model the chamber analog was used which describes whole cardiovascular system as a set of elastic chambers. The proposed model consists of systemic and pulmonary circulation, four-chamber heart and four valves. The description of heart is based on a four-element representation of a cardiac muscle. The reverse blood flow via valves is considered. The accuracy of the derived model was evaluated by comparing the data of numerical simulation with experimental data. The limitations of the model were discussed as well as possible applications of the model were suggested. The proposed lumped parameter model can be used to support clinicians in their decisions in treating cardiovascular disorders.
引用
下载
收藏
页数:21
相关论文
共 50 条
  • [41] Lumped parameter models of cardiovascular circulation in normal and arrhythmia cases
    Jung, Eunok
    Lee, Wanho
    JOURNAL OF THE KOREAN MATHEMATICAL SOCIETY, 2006, 43 (04) : 885 - 897
  • [42] Study on lumped parameter model for simulation of ventilator
    Department of Electronic Engineering, Information School, Yunnan University, Kunming 650091, China
    Xitong Fangzhen Xuebao, 2006, 10 (2959-2962):
  • [43] Lumped parameter model for chemically amplified resists
    Byers, J
    Smith, M
    Mack, C
    OPTICAL MICROLITHOGRAPHY XVII, PTS 1-3, 2004, 5377 : 1462 - 1474
  • [44] IMPROVEMENT OF FLUID PIPE LUMPED PARAMETER MODEL
    Kong XiaowuWei JianhuaQiu MinxiuWu GenmaoState Key Laboratory of Fluid PowerTransmission and Control
    Chinese Journal of Mechanical Engineering, 2004, (01) : 114 - 116
  • [45] A Distributed Lumped Parameter Model of Blood Flow
    Mirramezani, Mehran
    Shadden, Shawn C.
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (12) : 2870 - 2886
  • [46] Lumped parameter model for concentric canister launcher
    Fu, D.-B. (fdba@263.net), 1600, Journal of Solid Rocket Technology, P.O. Box 120, Xi'an, 710025, China (35):
  • [47] A Distributed Lumped Parameter Model of Blood Flow
    Mehran Mirramezani
    Shawn C. Shadden
    Annals of Biomedical Engineering, 2020, 48 : 2870 - 2886
  • [48] Lumped parameter model for multimode laser cutting
    Li, YG
    Latham, WP
    Kar, A
    OPTICS AND LASERS IN ENGINEERING, 2001, 35 (06) : 371 - 386
  • [49] Lumped parameter model of a variable displacement pump
    Wright, J.
    Burton, R.
    Schoenau, G.
    Journal of fluid control, 1988, 19 (02): : 37 - 57
  • [50] COUNTERFLOW HEAT EXCHANGERS - LUMPED PARAMETER MODEL
    KRISHNAM.VV
    INDIAN JOURNAL OF TECHNOLOGY, 1966, 4 (03): : 65 - &