A LUMPED PARAMETER MODEL OF CARDIOVASCULAR SYSTEM WITH PULSATING HEART FOR DIAGNOSTIC STUDIES

被引:13
|
作者
Frolov, S. V. [1 ]
Sindeev, S. V. [1 ]
Lischouk, V. A. [2 ]
Gazizova, D. Sh. [2 ]
Liepsch, D. [3 ]
Balasso, A. [4 ]
机构
[1] Tambov State Tech Univ, Dept Biomed Engn, Sovetskaya St 106, Tambov, Russia
[2] Bakoulev Ctr Cardiovasc Surg, Lab Math Modeling & Monitoring, Roublyevskoe Shosse 135, Moscow, Russia
[3] Munich Univ Appl Sci, Dept Bldg Serv Engn Paper & Packaging Technol & P, Lothstr 34, Munich, Germany
[4] Tech Univ Munich, Dept Neuroradiol, Klinikum Rechts Isar, Ismaninger Str 22, Munich, Germany
关键词
Cardiac modeling; patient-specific simulation; model of global hemodynamics; lumped parameter model; IN-VITRO; SIMULATION; VALIDATION;
D O I
10.1142/S0219519417500567
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mathematical modeling of cardiovascular system provides an ability to study hemodynamics and to predict the results of treatment based on individual anatomical and physiological data of patients. However, the presently developed models of cardiovascular system have a limitation on use in clinical practice due to their physical and computational complexities. The aim of this study is to derive a lumped parameter model of cardiovascular system with pulsating heart in which all parameters have a physically based quantitative value and can be identified using clinical methods. For development of a cardiovascular system model the chamber analog was used which describes whole cardiovascular system as a set of elastic chambers. The proposed model consists of systemic and pulmonary circulation, four-chamber heart and four valves. The description of heart is based on a four-element representation of a cardiac muscle. The reverse blood flow via valves is considered. The accuracy of the derived model was evaluated by comparing the data of numerical simulation with experimental data. The limitations of the model were discussed as well as possible applications of the model were suggested. The proposed lumped parameter model can be used to support clinicians in their decisions in treating cardiovascular disorders.
引用
下载
收藏
页数:21
相关论文
共 50 条
  • [21] An integrated lumped-parameter model of the cardiovascular system for the simulation of acute ischemic stroke: description of instantaneous changes in hemodynamics
    Civilla, Lorenzo
    Sbrollini, Agnese
    Burattini, Laura
    Morettini, Micaela
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2021, 18 (04) : 3993 - 4010
  • [22] CLOSED-LOOP LUMPED PARAMETER CARDIOVASCULAR MODEL OF INFARCT BORDER ZONE PACING
    Pilla, James J.
    Koomalsingh, Kevin
    Gorman, Robert C.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 641 - 642
  • [24] A dynamic lumped parameter model of injection cooling system for liquid subcooling
    Saha, Pritam
    Sandilya, Pavitra
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 132 : 552 - 557
  • [25] On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
    Kim, H. J.
    Vignon-Clementel, I. E.
    Figueroa, C. A.
    LaDisa, J. F.
    Jansen, K. E.
    Feinstein, J. A.
    Taylor, C. A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) : 2153 - 2169
  • [26] On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
    H. J. Kim
    I. E. Vignon-Clementel
    C. A. Figueroa
    J. F. LaDisa
    K. E. Jansen
    J. A. Feinstein
    C. A. Taylor
    Annals of Biomedical Engineering, 2009, 37 : 2153 - 2169
  • [27] Development of a Lumped Parameter Model for an Aeronautic Hybrid Electric Propulsion System
    Frosina, Emma
    Senatore, Adolfo
    Palumbo, Luka
    Di Lorenzo, Giuseppe
    Pascarella, Ciro
    AEROSPACE, 2018, 5 (04)
  • [28] Towards a transformer transient model as a lumped-distributed parameter system
    Zirka, Sergey E.
    Moroz, Yuriy I.
    Rahimpour, Ebrahim
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 36 (03) : 741 - 750
  • [29] A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1982, 57 (1-2) : 175 - 185
  • [30] A LUMPED PARAMETER MODEL OF THE UPPER AIRWAY
    HANTOS, Z
    GALGOCZY, G
    DAROCZY, B
    CSENDES, T
    KLEBNICZKI, J
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1982, 18 (04): : P48 - P49