Comparison between an inhibition enzymatic sensor and toxicity biosensors in the determination of polluting metal ions

被引:0
|
作者
Campanella, L [1 ]
Favero, G [1 ]
Mastrofini, D [1 ]
Piccinelli, L [1 ]
Tomassetti, M [1 ]
Torresi, A [1 ]
机构
[1] Univ Rome La Sapienza, Dipartimento Chim, I-00185 Rome, Italy
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present research two different types of biosensor were developed to heavy metal ion determination: a classical glucose oxidase inhibition biosensor and an immobilised cell toxicity biosensor using as transducer a CO2 gaseous diffusion electrode of the potentiometric type. A comparison was also made between the responses of these biosensors and those obtained in previous tests using a immobilised cell toxicity biosensor in which the transducer consisted of a O-2 gaseous diffusion electrode of the amperometric type.
引用
收藏
页码:687 / 696
页数:10
相关论文
共 50 条
  • [41] COMPARISON OF SPECTROFLUOROMETRY AND ION-SELECTIVE ELECTRODE POTENTIOMETRY FOR DETERMINATION OF COMPLEXES BETWEEN FULVIC-ACID AND HEAVY-METAL IONS
    SAAR, RA
    WEBER, JH
    ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2095 - 2100
  • [42] DETERMINATION OF BONDS BETWEEN METAL IONS AND ADDITIVES BY MEANS OF SURFACE PRESSURE AND INFRARED SPECTRA
    FRIBERG, SE
    MULLER, H
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 1970, 22 (08) : 208 - &
  • [43] Determination of Binding Constants for the Complexes Between Heavy Metal Ions and Cucurbit[n]uril
    Murray, Alenzo
    Baker, Priscilla
    Iwuoha, Emmanuel
    CHEMISTRYSELECT, 2024, 9 (18):
  • [44] Wien effect determination of adsorption energies between heavy metal ions and soil particles
    Wang, Yu-Jun
    Li, Cheng-Bao
    Wang, Wei
    Zhou, Dong-Mei
    Xu, Ren-Kou
    Friedman, Shmulik P.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2008, 72 (01) : 56 - 62
  • [45] Determination of Heavy Metal Ions in Infant Milk Powder Using a Nanoporous Carbon Modified Disposable Sensor
    Chen, Han
    Yao, Yao
    Zhang, Chao
    Ping, Jianfeng
    FOODS, 2023, 12 (04)
  • [46] A novel 8-hydroxyquinoline PVC coated graphite sensor for potentiometric determination of some metal ions
    Arida, HAM
    ANALYTICAL LETTERS, 2002, 35 (15) : 2421 - 2431
  • [47] Comparison of the determination of metal ions in water samples by rotating disk voltammetry and atomic absorption spectroscopy
    Kennedy, Sarah
    Rickard, Lyman
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [48] Comparison of novel sorbents for preconcentration of metal ions prior to their flame atomic absorption spectrometry determination
    Ghaedi, M.
    Montazerozohori, M.
    Sajedi, M.
    Roosta, M.
    Jahromi, M. Nickoosiar
    Asghari, A.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2013, 19 (06) : 1781 - 1787
  • [49] MODELING OF THE ENZYMATIC CELLOBIOSE HYDROLYSIS - COMPARISON BETWEEN LINEAR AND NON-LINEAR DETERMINATION OF THE PARAMETERS
    BAUER, F
    KUDE, J
    ACTA BIOTECHNOLOGICA, 1985, 5 (03): : 271 - 278
  • [50] Immunochemical determination of oxytetracycline in fish: Comparison between enzymatic and time-resolved fluorometric assays
    Chafer-Pericas, Consuelo
    Maquieira, Angel
    Puchades, Rosa
    Miralles, Javier
    Moreno, Amelia
    Pastor-Navarro, Nuria
    Espinos, Francisco
    ANALYTICA CHIMICA ACTA, 2010, 662 (02) : 177 - 185