Comparison between an inhibition enzymatic sensor and toxicity biosensors in the determination of polluting metal ions

被引:0
|
作者
Campanella, L [1 ]
Favero, G [1 ]
Mastrofini, D [1 ]
Piccinelli, L [1 ]
Tomassetti, M [1 ]
Torresi, A [1 ]
机构
[1] Univ Rome La Sapienza, Dipartimento Chim, I-00185 Rome, Italy
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present research two different types of biosensor were developed to heavy metal ion determination: a classical glucose oxidase inhibition biosensor and an immobilised cell toxicity biosensor using as transducer a CO2 gaseous diffusion electrode of the potentiometric type. A comparison was also made between the responses of these biosensors and those obtained in previous tests using a immobilised cell toxicity biosensor in which the transducer consisted of a O-2 gaseous diffusion electrode of the amperometric type.
引用
收藏
页码:687 / 696
页数:10
相关论文
共 50 条
  • [31] Hybridization between Crotalus aquilus and Crotalus polystictus Species: A Comparison of Their Venom Toxicity and Enzymatic Activities
    Roldan-Padron, Octavio
    Sandra Cruz-Perez, Martha
    Luis Castro-Guillen, Jose
    Alejandro Garcia-Arredondo, Jose
    Mendiola-Olaya, Elizabeth
    Saldana-Gutierrez, Carlos
    Herrera-Paniagua, Patricia
    Blanco-Labra, Alejandro
    Garcia-Gasca, Teresa
    BIOLOGY-BASEL, 2022, 11 (05):
  • [32] EMISSION OF NEGATIVE-IONS BY SPUTTERING - A COMPARISON BETWEEN PURE METAL AND METAL ACETATE TARGETS
    GONELLA, C
    REMY, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1982, 41 (04): : 277 - 281
  • [33] Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
    Puy-Llovera, Jaume
    Perez-Rafols, Clara
    Serrano, Nutiria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 175 : 501 - 506
  • [34] A Simple Flow Injection pH Indicator Method for the Determination of Metal Ions by Urease Inhibition Study
    Rasheed, Aamir
    Ghous, Tahseen
    Khan, Muhammad
    Ullah, Raja Summe
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (02): : 317 - 320
  • [35] DETERMINATION OF THE UREASE ACTIVITY AND THE RELATIVE INHIBITION IN THE PRESENCE OF SOME METAL-IONS - A MICROCALORIMETRIC STUDY
    ANTONELLI, ML
    CARUNCHIO, V
    LUCIANI, M
    VINCI, G
    THERMOCHIMICA ACTA, 1987, 122 (01) : 95 - 103
  • [36] COMPARISON BETWEEN RADIOIMMUNOLOGICAL AND IMMUNO-ENZYMATIC PROCEDURES FOR DETERMINATION OF MB ISOENZYME OF CREATINEPHOSPHOKINASE
    CLERICO, A
    DELCHICCA, MG
    BUZZIGOLI, G
    BONI, C
    GIAMPIETRO, O
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1983, 27 (02): : 91 - 92
  • [37] COMPARISON BETWEEN ACID AND ENZYMATIC-HYDROLYSIS OF STARCH FOR DETERMINATION OF TOTAL REDUCING SUGARS
    SCHMIDELL, W
    REVISTA DE MICROBIOLOGIA, 1977, 8 (03): : 98 - 101
  • [38] CORRELATIONS BETWEEN PAIRS OF SIMPLE PHYSICOCHEMICAL PARAMETERS OF METAL-IONS AND ACUTE TOXICITY IN MICE
    TURNER, JE
    ENGLAND, MW
    HINGERTY, BE
    HAYDEN, TL
    SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 68 : 275 - 280
  • [39] An enzymatic activity regulation-based clusterzyme sensor array for high-throughput identification of heavy metal ions
    Li, Yueyuan
    Mu, Zhaode
    Yuan, Yonghua
    Zhou, Jing
    Bai, Lijuan
    Qing, Min
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 454
  • [40] Kinetics Study of Adsorption Behaviors of Trivalent Metal Ions onto Chelating Resin: Comparison between Scandium(III) and Other Metal Ions
    Watanabe, Hiroto
    Asano, Satoshi
    Murase, Kuniaki
    MATERIALS TRANSACTIONS, 2024, 65 (01) : 61 - 70