Optimization of the Design and Operating Conditions of an Amperometric Biosensor for Glutamate Concentration Measurements in the Blood Plasma

被引:3
|
作者
Mruga, D. [1 ,3 ]
Soldatkin, O. [1 ,3 ]
Paliienko, K. [2 ]
Topcheva, A. [2 ]
Krisanova, N. [2 ]
Kucherenko, D. [1 ,3 ]
Borisova, T. [2 ]
Dzyadevych, S. [3 ]
Soldatkin, A. [3 ]
机构
[1] NASU, Inst Mol Biol & Genet, Dept Biomol Elect, 150 Zabolotnogo Str, UA-03680 Kiev, Ukraine
[2] NASU, Palladin Inst Biochem, Dept Neurochem, 9 Leontovicha Str, UA-01601 Kiev, Ukraine
[3] Taras Shevchenko Natl Univ Kyiv, Inst High Technol, 64 Volodymyrska Str, UA-01003 Kiev, Ukraine
基金
新加坡国家研究基金会;
关键词
amperometric biosensor; glutamate; glutamate oxidase; measurement of amino acids content in the blood; FLOW-INJECTION ANALYSIS; CAPILLARY-ELECTROPHORESIS; FOOD; DEHYDROGENASE; OXIDASE; MICRODIALYSIS; DECARBOXYLASE; SPECTROMETRY; REAGENTLESS; ELECTRODES;
D O I
10.1002/elan.202060449
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Today, the concentration of glutamate in the patient ' s blood is an important indicator in medical diagnostics; therefore, it is necessary to have a simple, accurate, and fast tool to obtain the data. Here, a recently developed amperometric glutamate-sensitive biosensor was optimized to improve its characteristics. The platinum disk electrode was used as a transducer. As a bioselective element we used the enzyme glutamate oxidase, covalently crosslinked with bovine serum albumin by glutaraldehyde. Circumstances of enzyme immobilization on the transducer's surface were optimized (enzyme and glutaraldehyde concentrations and immobilization duration). To test the ability of this biosensor to work in biological environments containing complex biological substances, the influence of the working solution was investigated (concentration of the working buffer, its temperature, presence of the protein in the analyzed sample). The linear range of biosensor was from 5 to 600 mu M of glutamate and the sensitivity was 150-200 nA/mM. Measurements of glutamate concentrations in the blood plasma were performed by biosensor and glutamate dehydrogenase assay. The linear correlation between the methods was found in a range of 50.4-182.5 mu M (R-2=0.99). Thus, it has been shown that the developed biosensor makes it possible to measure the concentration of glutamate in blood plasma.
引用
收藏
页码:1299 / 1307
页数:9
相关论文
共 50 条
  • [41] Microalgae Concentration through Microfiltration and Forward Osmosis: Evaluation of Membrane Setup Design and Operating Conditions
    Padilla, Cinthia
    Rodriguez-Roda, Ignasi
    Blandin, Gaetan
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2025, 151 (04)
  • [42] Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements
    Pflegerl, K
    Hahn, R
    Schallaun, E
    Josic, D
    Jungbauer, A
    JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (02): : 335 - 347
  • [43] Design, Simulation and Optimization of MEMS-based Piezoresistive Biosensor with Stress Concentration Region for Biosensing Applications
    Busi, Rambabu
    Talam, Satyanarayana
    Reddy, Arthikeya
    Reddy, T. Ashok
    Naveen, R. Gowtham Arun Kumar R.
    Jyothiram, C. H.
    Harshada, M.
    JOURNAL OF ACTIVE AND PASSIVE ELECTRONIC DEVICES, 2024, 18 (02): : 153 - 160
  • [44] PIV measurements in the impeller and the vaneless diffuser of a radial flow pump in design and off-design operating conditions
    Wuibaut, G
    Bois, G
    Dupont, P
    Caignaert, G
    Stanislas, M
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 791 - 797
  • [45] MEASUREMENTS OF ENDOGENOUS GLUCAGON IN PLASMA AND INFLUENCE OF BLOOD GLUCOSE CONCENTRATION UPON ITS SECRETION
    UNGER, RH
    EISENTRAUT, AM
    MCCALL, MS
    MADISON, LL
    JOURNAL OF CLINICAL INVESTIGATION, 1962, 41 (04): : 682 - &
  • [46] Whole blood heparin concentration measurements by automated protamine titration agree with plasma anti-Xa measurements
    Despotis, GJ
    Joist, JH
    Goodnough, LT
    Santoro, SA
    Spitznagel, E
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (03): : 611 - 613
  • [47] Entropy maximizing evolutionary design optimization of water distribution networks under multiple operating conditions
    Tanyimboh T.T.
    Czajkowska A.M.
    Environment Systems and Decisions, 2021, 41 (2) : 267 - 285
  • [48] OPTIMIZATION OF SESAME SEEDS OIL EXTRACTION OPERATING CONDITIONS USING THE RESPONSE SURFACE DESIGN METHODOLOGY
    Osman, Haitham
    Shigidi, Ihab
    Elkhaleefa, Abubakr
    SCIENTIFIC STUDY AND RESEARCH-CHEMISTRY AND CHEMICAL ENGINEERING BIOTECHNOLOGY FOOD INDUSTRY, 2016, 17 (04): : 335 - 347
  • [49] Parametrical Modeling and Design Optimization of Blood Plasma Separation Device with Microchannel Mechanism
    Xue, Xiangdong
    Patel, Mayur K.
    Kersaudy-Kerhoas, Maiwenn
    Bailey, Chris
    Desmulliez, Marc P. Y.
    2009 IEEE 59TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE, VOLS 1-4, 2009, : 1970 - +
  • [50] CHANGES OF CONCENTRATION OF SUBSTANCE-P IN THE PLASMA OF RATS AT DIFFERENT CONDITIONS OF THE BLOOD-LETTING
    FENDIUS, RR
    RATHSACK, R
    HINZ, G
    GUTEWORT, T
    PHARMAZIE, 1987, 42 (08): : 535 - 536