Optimization of the Design and Operating Conditions of an Amperometric Biosensor for Glutamate Concentration Measurements in the Blood Plasma

被引:3
|
作者
Mruga, D. [1 ,3 ]
Soldatkin, O. [1 ,3 ]
Paliienko, K. [2 ]
Topcheva, A. [2 ]
Krisanova, N. [2 ]
Kucherenko, D. [1 ,3 ]
Borisova, T. [2 ]
Dzyadevych, S. [3 ]
Soldatkin, A. [3 ]
机构
[1] NASU, Inst Mol Biol & Genet, Dept Biomol Elect, 150 Zabolotnogo Str, UA-03680 Kiev, Ukraine
[2] NASU, Palladin Inst Biochem, Dept Neurochem, 9 Leontovicha Str, UA-01601 Kiev, Ukraine
[3] Taras Shevchenko Natl Univ Kyiv, Inst High Technol, 64 Volodymyrska Str, UA-01003 Kiev, Ukraine
基金
新加坡国家研究基金会;
关键词
amperometric biosensor; glutamate; glutamate oxidase; measurement of amino acids content in the blood; FLOW-INJECTION ANALYSIS; CAPILLARY-ELECTROPHORESIS; FOOD; DEHYDROGENASE; OXIDASE; MICRODIALYSIS; DECARBOXYLASE; SPECTROMETRY; REAGENTLESS; ELECTRODES;
D O I
10.1002/elan.202060449
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Today, the concentration of glutamate in the patient ' s blood is an important indicator in medical diagnostics; therefore, it is necessary to have a simple, accurate, and fast tool to obtain the data. Here, a recently developed amperometric glutamate-sensitive biosensor was optimized to improve its characteristics. The platinum disk electrode was used as a transducer. As a bioselective element we used the enzyme glutamate oxidase, covalently crosslinked with bovine serum albumin by glutaraldehyde. Circumstances of enzyme immobilization on the transducer's surface were optimized (enzyme and glutaraldehyde concentrations and immobilization duration). To test the ability of this biosensor to work in biological environments containing complex biological substances, the influence of the working solution was investigated (concentration of the working buffer, its temperature, presence of the protein in the analyzed sample). The linear range of biosensor was from 5 to 600 mu M of glutamate and the sensitivity was 150-200 nA/mM. Measurements of glutamate concentrations in the blood plasma were performed by biosensor and glutamate dehydrogenase assay. The linear correlation between the methods was found in a range of 50.4-182.5 mu M (R-2=0.99). Thus, it has been shown that the developed biosensor makes it possible to measure the concentration of glutamate in blood plasma.
引用
收藏
页码:1299 / 1307
页数:9
相关论文
共 50 条
  • [21] Design and optimization of a lactate amperometric biosensor based on lactate oxidase cross-linked with polymeric matrixes
    Romero, Marcelo Ricardo
    Garay, Fernando
    Baruzzi, Ana M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02) : 590 - 595
  • [22] Optimization of the operating conditions in inductively coupled plasma optical emission spectrometry
    Velitchkova, N. S.
    Velichkov, S. V.
    Karadjov, M. G.
    Daskalova, N. N.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 152 - 159
  • [23] Application of bivariate parameter design to the optimization of the operating conditions of a turning process
    Chou, CY
    Chen, CH
    Yang, CC
    Wu, CC
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2005, 43 (24) : 5229 - 5240
  • [24] Hydrodynamic optimization for design and operating parameters of an innovative continuous-flow miniaturized MFC biosensor
    Xiao, Nan
    Wang, Bing
    Huang, Jinhui Jeanne
    CHEMICAL ENGINEERING SCIENCE, 2021, 235
  • [25] Operating condition design with a Bayesian optimization approach for pharmaceutical intermediate batch concentration
    Liu, Chong
    Han, Chengyu
    Gu, Chenxi
    Sun, Wei
    Wang, Jingde
    Tang, Xun
    COMPUTERS & CHEMICAL ENGINEERING, 2024, 189
  • [26] Optimization of nitric oxide chemiluminescence operating conditions for measurement of plasma nitrite and nitrate
    Bateman, RM
    Ellis, CG
    Freeman, DJ
    CLINICAL CHEMISTRY, 2002, 48 (03) : 570 - 573
  • [27] WHOLE-BLOOD VERSUS PLASMA MEASUREMENTS OF GLUTAMATE AND ALANINE ACROSS THE HUMAN MYOCARDIUM
    THOMASSEN, AR
    NIELSEN, TT
    BAGGER, JP
    HENNINGSEN, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1987, 47 (03): : 293 - 300
  • [28] An optimization based methodology to design flexible systems subjected to changing operating conditions
    Khire, Ritesh A.
    Mullur, Anoop A.
    Messac, Achille
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2005, VOL 2, PTS A AND B, 2005, : 199 - 211
  • [29] Advancing the Design and Operating Conditions for Block Freeze Concentration of Urine-Derived Fertilizer
    Noe-Hays, Abraham
    Homeyer, Ryan John
    Davis, Arthur P.
    Love, Nancy G.
    ACS ES&T ENGINEERING, 2022, 2 (03): : 446 - 455
  • [30] Red Fruit Juice Concentration by Osmotic Distillation: Optimization of Operating Conditions by Response Surface Methodology
    Ruby-Figueroa, Rene
    Morelli, Rosanna
    Conidi, Carmela
    Cassano, Alfredo
    MEMBRANES, 2023, 13 (05)