Optimization of the Design and Operating Conditions of an Amperometric Biosensor for Glutamate Concentration Measurements in the Blood Plasma

被引:3
|
作者
Mruga, D. [1 ,3 ]
Soldatkin, O. [1 ,3 ]
Paliienko, K. [2 ]
Topcheva, A. [2 ]
Krisanova, N. [2 ]
Kucherenko, D. [1 ,3 ]
Borisova, T. [2 ]
Dzyadevych, S. [3 ]
Soldatkin, A. [3 ]
机构
[1] NASU, Inst Mol Biol & Genet, Dept Biomol Elect, 150 Zabolotnogo Str, UA-03680 Kiev, Ukraine
[2] NASU, Palladin Inst Biochem, Dept Neurochem, 9 Leontovicha Str, UA-01601 Kiev, Ukraine
[3] Taras Shevchenko Natl Univ Kyiv, Inst High Technol, 64 Volodymyrska Str, UA-01003 Kiev, Ukraine
基金
新加坡国家研究基金会;
关键词
amperometric biosensor; glutamate; glutamate oxidase; measurement of amino acids content in the blood; FLOW-INJECTION ANALYSIS; CAPILLARY-ELECTROPHORESIS; FOOD; DEHYDROGENASE; OXIDASE; MICRODIALYSIS; DECARBOXYLASE; SPECTROMETRY; REAGENTLESS; ELECTRODES;
D O I
10.1002/elan.202060449
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Today, the concentration of glutamate in the patient ' s blood is an important indicator in medical diagnostics; therefore, it is necessary to have a simple, accurate, and fast tool to obtain the data. Here, a recently developed amperometric glutamate-sensitive biosensor was optimized to improve its characteristics. The platinum disk electrode was used as a transducer. As a bioselective element we used the enzyme glutamate oxidase, covalently crosslinked with bovine serum albumin by glutaraldehyde. Circumstances of enzyme immobilization on the transducer's surface were optimized (enzyme and glutaraldehyde concentrations and immobilization duration). To test the ability of this biosensor to work in biological environments containing complex biological substances, the influence of the working solution was investigated (concentration of the working buffer, its temperature, presence of the protein in the analyzed sample). The linear range of biosensor was from 5 to 600 mu M of glutamate and the sensitivity was 150-200 nA/mM. Measurements of glutamate concentrations in the blood plasma were performed by biosensor and glutamate dehydrogenase assay. The linear correlation between the methods was found in a range of 50.4-182.5 mu M (R-2=0.99). Thus, it has been shown that the developed biosensor makes it possible to measure the concentration of glutamate in blood plasma.
引用
收藏
页码:1299 / 1307
页数:9
相关论文
共 50 条
  • [1] An amperometric glutamate biosensor for monitoring glutamate release from brain nerve terminals and in blood plasma
    Borisova, T.
    Kucherenko, D.
    Soldatkin, O.
    Kucherenko, I.
    Pastukhov, A.
    Nazarova, A.
    Galkin, M.
    Borysov, A.
    Krisanova, N.
    Soldatkin, A.
    El'skaya, A.
    ANALYTICA CHIMICA ACTA, 2018, 1022 : 113 - 123
  • [2] Study of operating conditions in concentration of chicken blood plasma proteins by ultrafiltration
    Torres, MR
    Marín, FR
    Ramos, AJ
    Soriano, E
    JOURNAL OF FOOD ENGINEERING, 2002, 54 (03) : 215 - 219
  • [3] MEMS biosensor for blood plasma viscosity measurements
    Cakmak, Onur
    Elbuken, Caglar
    Ermek, Erhan
    Bulut, Selma
    Kilinc, Yasin
    Baris, Ibrahim
    Kavakli, Halil
    Alaca, Erdem
    Urey, Hakan
    NEW BIOTECHNOLOGY, 2012, 29 : S162 - S163
  • [4] Amperometric Enzyme Biosensor for the Determination of High Concentration Lactate in Whole Blood of Athletes
    Chunxiu Liu Zonghui Guo Hui Wang Jianfang Xu Lianshi Feng Xinxia Cai State Key Laboratory of Transducer TechnologyInstitute of ElectronicsChinese Academy of SciencesBeijing China Graduate School of Chinese Academy of SciencesBeijing China Biology CenterChina Institute of Sport ScienceBeijing China
    稀有金属材料与工程, 2006, (S3) : 83 - 86
  • [5] Development and study of an amperometric biosensor for the in vitro measurement of low concentration of putrescine in blood
    Nagy, L
    Nagy, G
    Gyurcsányi, RE
    Neuman, MR
    Lindner, E
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 53 (1-3): : 165 - 175
  • [6] Amperometric enzyme biosensor for the determination of high concentration lactate in whole blood of athletes
    Liu, Chunxiu
    Guo, Zonghui
    Wang, Hui
    Xu, Jianfang
    Feng, Lianshi
    Cai, Xinxia
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 83 - 86
  • [7] ELIMINATION OF ELECTROCHEMICALLY-ACTIVE INTERFERENTS IN AMPEROMETRIC BIOSENSOR MEASUREMENTS - APPLICATION TO ONLINE MONITORING OF GLUCOSE AND GLUTAMATE
    KOSHY, A
    ZILKHA, E
    OBRENOVITCH, TP
    BENNETTO, HP
    RICHARDS, DA
    SYMON, L
    ANALYTICAL LETTERS, 1993, 26 (05) : 831 - 849
  • [8] Optimization of microstrip gas chamber design and operating conditions
    Beckers, T.
    Bouclier, R.
    Garabatos, Ch.
    Million, G.
    Sauli, F.
    Shekhtman, L.I.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A346 (1-2) : 95 - 101
  • [9] Monitoring of Sodium Concentration in Blood Plasma Using CSIW RF Biosensor
    Azad, Prakrati
    Kumari, Ankita
    Akhtar, M. Jaleel
    2024 IEEE APPLIED SENSING CONFERENCE, APSCON, 2024,
  • [10] Measurement of glucose concentration in blood plasma based on a wireless magnetoelastic biosensor
    Pang, Pengfei
    Yang, Wenyue
    Huang, Sijing
    Cai, Qingyun
    Yao, Shouzhuo
    ANALYTICAL LETTERS, 2007, 40 (05) : 897 - 906