Slotted Beam-Column Energy Dissipating Connections: Applicability and Seismic Behavior

被引:5
|
作者
Zhao, Xin [1 ,2 ]
Qi, Ai [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Fujian Jiangxia Univ, Coll Engn, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
SLIT DAMPERS;
D O I
10.1155/2021/5530083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy dissipating joint can effectively strengthen the connection of prefabricated buildings. In the present study, a new slotted mild steel damper was installed at the beam end of the prefabricated structure to form as the energy-dissipating joint of the beam-column. By using ABAQUS software, a finite element (FE) analysis was conducted for the single-story-and-span of the single-frame structure with a slotted damper as energy-dissipating joint. The result shows that the damper was the first to yield in the structure and performed well in energy dissipation, indicating its reasonable design of structure and connection. The energy dissipation mainly occurred at the flange of the variable cross sections, between which beam-ribbed webs ensured the required bearing capacity and stiffness and provided a reliable connection. The hysteretic curves were obtained by analyzing the mechanical properties of the slotted damper under pure bending and pure shearing. In the OpenSees platform, the Steel02 Material model and the twoNodeLink element were used to fit the hysteretic curves; this method was employed for the parametric simulation of the slotted energy dissipation. The dynamic characteristics and seismic response of the controlled structure with slotted energy dissipating joint were also analyzed and compared with those of the uncontrolled structure in the OpenSees platform. The results show that the period of the controlled structure was prolonged and the top story acceleration decreased, indicating its effect in reducing seismic response. The shear-dependent seismic reduction ratio was about 35%, while the drift-dependent seismic reduction ratio was about 10%. The seismic performance of bottom story was better than that of the top story, and the damper has good energy dissipation performance in the bending direction. Some detailed design criteria are put forward and consequences for design on the basis of the performed simulations are shown.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Experimental study on cyclic behavior of improved beam-column connections
    Li, ZF
    Shi, YJ
    Chen, H
    Wang, YQ
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 213 - 220
  • [42] Experimental Research on Hysteretic Behavior of Angles Beam-column Connections
    Wang, Xinwu
    PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL VI: MODELLING AND SIMULATION IN ARCHITECTURE, CIVIL ENGINEERING AND MATERIALS, 2008, : 271 - 275
  • [43] Experimental Research on Seismic Behavior of Non-Rigid Steel Beam-Column Connections with Concrete Cover
    Jiang Lixue
    Zhou Feng
    Zheng Qiaowen
    7TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTIONS: STRENGTHENING AND RETROFITTING, PTS 1 AND 2, 2010, 133-134 : 1233 - 1239
  • [44] Seismic behavior of steel beam-column connection with assembled steel rod energy dissipaters
    Zhong, Yun-Long
    Li, Guo-Qiang
    Xiang, Yang
    Wang, Yan-Bo
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [45] Numerical study on seismic behavior of H-beams with wing plates for bolted beam-column connections
    Wu, Lai-Yun
    Chung, Lap-Loi
    Wang, Ming-Tzong
    Huang, Guo-Luen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) : 97 - 115
  • [46] Experimental study on effect of length of service hole on seismic behavior of exterior precast beam-column connections
    Liu, Yangqing
    Cai, Jianguo
    Deng, Xiaowei
    Cao, Yunfeng
    Feng, Jian
    STRUCTURAL CONCRETE, 2019, 20 (01) : 85 - 96
  • [47] Shear behavior of exterior reinforced concrete column-steel beam beam-column connections
    Shen, Hong-Xia
    Gu, Qiang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (SUPPL. 1): : 154 - 161
  • [48] Seismic behavior and restoring force model of precast beam-column connections with locally reactive powder concrete
    Yu, Jianbing
    Xia, Yufeng
    Guan, Dongzhi
    Guo, Xuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [49] Seismic behavior of 3-D ECC beam-column connections subjected to bidirectional bending and torsion
    Hosseini, Farshid
    Gencturk, Bora
    Aryan, Hadi
    Cadaval, Gustavo
    ENGINEERING STRUCTURES, 2018, 172 : 751 - 763
  • [50] Seismic Behavior of Hybrid Concrete Beam-Column Connections with Composite Beams and Cast-in-Place Columns
    Xue, Weichen
    Zhang, Bin
    ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 617 - 627